Researcher profile

Klaus Scheffler

Klaus Scheffler contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
1topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2026arXiv

Group-kernel auto-calibration and group-patch k-space reconstruction: Fast MRI with time-variant B0 kernels partitioned into time-invariant subsets

Purpose: Pushing MRI speed further demands more spatially-encoded information captured per unit time, e.g., by superimposing additional field modulations during oversampled readout. However, this can introduce calibration errors and increase reconstruction time. Thus, we propose a continuous field calibration approach and an efficient k-space reconstruction technique. Theory and Methods: Our auto-calibration generalizes GRAPPA kernels to explicitly extract continuous B0 modulation kernels, solving interpolation relationships between two ACS regions differing only in the extra field modulation. The k-space locations sharing the same instantaneous image-space modulation are grouped, so that subsets of time-invariant kernels can be separately estimated, as a generalized solution for Wave-CAIPI/FRONSAC-type scans. This view further inspires a k-space subregion-wise reconstruction technique, as an efficient alternative to conventional hybrid-space reconstruction. At 9.4T, FLASH accelerated by a local B0 coil array and Wave-CAIPI were tested with retrospective undersampling. Results: Artifact-free images were reconstructed, under diverse rapid B0 modulation schemes, reaching maximum acceleration factors of 8-fold in 2D and 14.6-fold in 3D. Some nonlinear gradients modulation schemes reach similar sampling efficiency as linear gradients modulation. The proposed reconstruction shows potentials in reducing reconstruction time. Conclusion: Rapid B0 modulations and widely-adopted parallel imaging can share a common mathematical framework, and consequently, achieve similarly-robust reconstructions. Specifically, for scans using dynamic B0 and static RF kernels, not only signal encoding, but also auto-calibration and reconstruction can be performed in k-space. This paves the way to robustly remove eddy currents, and explore more complex B0 modulation strategies towards ultimate MRI speed.

preprint2026arXiv

Group-patch joint compression for highly accelerated MRI: compressing dynamic B0 and static RF spatial modulations across k-space subregion groups

Purpose: To accelerate MRI further, rapid B0 field modulations can be applied during oversampled readout to capture additional physical information, e.g., Wave-CAIPI, FRONSAC, local B0 coils modulations. These methods, however, introduce additional non-Fourier-encoded dimension that cannot be resolved by FFT, posing significant reconstruction challenges particularly in compressed-sensing or neural-network frameworks. Theory and methods: Because B0 modulations vary slowly relative to the oversampled ADC dwell time, we exploit this encoding redundancy by compressing k-space patch-by-patch across subregions, each of which is jointly encoded by a distinct subset of B0 and RF (receive) spatial encoding functions. For each patch, a compression matrix is computed once and reused to compress all patches encoded by the same B0/RF spatial modulations. This can be implemented by feeding subsets of B0 and RF spatial encoding maps into an adapted conventional RF array compression algorithm, mimicking an expanded set of virtual receiver channels. This approach was evaluated on ex-vivo/in-vivo human brain scans at 9.4T/3T. Results: The proposed group-patch joint compression achieves substantially higher compression factors than conventional RF-only compression, while minimally compromising encoding efficiency. Typically, joint compression factors of 11x-20x led to negligible encoding loss, dramatically reducing reconstruction time and peak memory usage. For example, compressed-sensing reconstruction took 1.4-5.1s/2D slice, 177s-10.1min/3D volume, on a high-memory CPU node. Conclusion: Given joint encoding of dynamic B0 and static RF fields, compressing multidimensional k-space patches in separate groups outperforms compressing RF receiver channels alone. This substantially mitigates a fundamental computational bottleneck that arises when combining rapid B0 and RF-receiver modulations.

preprint2026arXiv

Overcoming the limitations of NMR Field Probes: A Novel Integrated Sensor Utilizing Pre-Polarization for (Ultra) Low Field MRI

Access to magnetic resonance imaging (MRI) remains severely limited in low- and middle-income countries, especially in sub-Saharan Africa, despite rising rates of non-communicable diseases. Low-field MRI presents an affordable, locally developable diagnostic solution, but its performance is constrained by magnetic field instability. We present a novel NMR field probe designed to overcome these challenges using a rapid non-adiabatic switch-off of a pre-polarization field resulting in precessing spin magnetization. Achieved by first use of high-voltage silicon carbide transistors operating in controlled avalanche breakdown, it measures the Larmor frequency without prior field knowledge, unlike conventional probes. This capability is crucial during magnet development with often unknown fields, allowing early detection of magnet issues, and offering an urgently needed tool for magnet design and image-quality improvement. Validated from 1 mT to 45 mT (up to 1,000 times stronger than similar systems) its low-cost, modular design supports replication, upgrades, and enhanced field control, helping expand global MRI access.

preprint2021arXiv

High-resolution neural network-driven mapping of multiple diffusion metrics leveraging asymmetries in the balanced SSFP frequency profile

We suggest to utilize the rich information content about microstructural tissue properties entangled in asymmetric balanced steady-state free precession (bSSFP) profiles to estimate multiple diffusion metrics simultaneously by neural network (NN) parameter quantification. A 12-point bSSFP phase-cycling scheme with high-resolution whole-brain coverage is employed at 3 T and 9.4 T for NN input. Low-resolution target diffusion data are derived based on diffusion-weighted spin-echo echo-planar-imaging (SE-EPI) scans, i.e., mean, axial, and radial diffusivity (MD, AD, RD), fractional anisotropy (FA) as well as the spherical coordinates (azimuth $Φ$ and inclination $Θ$) of the principal diffusion eigenvector. A feedforward NN is trained with incorporated probabilistic uncertainty estimation. The NN predictions yielded highly reliable results in white matter (WM) and gray matter (GM) structures for MD. The quantification of FA, AD, and RD was overall in good agreement with the reference but the dependence of these parameters on WM anisotropy was somewhat biased, e.g., in corpus callosum. The inclination $Θ$ was well predicted for anisotropic WM structures while the azimuth $Φ$ was overall poorly predicted. The findings were highly consistent across both field strengths. Application of the optimized NN to high-resolution input data provided whole-brain maps with rich structural details. In conclusion, the proposed NN-driven approach showed potential to provide distortion-free high-resolution whole-brain maps of multiple diffusion metrics at high to ultra-high field strengths in clinically relevant scan times.