Source author record

Thayakorn Wisutthisen

Explore this author’s publications, collaborators and research topics. This catalog record has not been claimed by its author.

ResearcherUnclaimed source record

Catalog footprint

Research overview

2works
1topics
4close collaborators

Published work

2 publications

preprint2020arXiv

Improving Heart Rate Estimation on Consumer Grade Wrist-Worn Device Using Post-Calibration Approach

The technological advancement in wireless health monitoring through the direct contact of the skin allows the development of light-weight wrist-worn wearable devices to be equipped with different sensors such as photoplethysmography (PPG) sensors. However, the motion artifact (MA) is possible to occur during daily activities. In this study, we attempted to perform a post-calibration of the heart rate (HR) estimation during the three possible states of average daily activity (resting, \textcolor{red}{laying down}, and intense treadmill activity states) in 29 participants (130 minutes/person) on four popular wearable devices: Fitbit Charge HR, Apple Watch Series 4, TicWatch Pro, and Empatica E4. In comparison to the standard measurement (HRECG_\text{ECG}), HR provided by Fitbit Charge HR (HRFitbit_\text{Fitbit}) yielded the highest error of 3.26±0.343.26 \pm 0.34 bpm in resting, 2.33±0.232.33 \pm 0.23 bpm in \textcolor{red}{laying down}, 9.53±1.479.53 \pm 1.47 bpm in intense treadmill activity states, and 5.02±0.645.02 \pm 0.64 bpm in all states combined among the four chosen devices. Following our improving HR estimation model with rolling windows as feature (HRR_\text{R}), the mean absolute error (MAE) was significantly reduced by 33.44%33.44\% in resting, 15.88%15.88\% in \textcolor{red}{laying down}, 9.55%9.55\% in intense treadmill activity states, and 18.73%18.73\% in all states combined. This demonstrates the feasibility of our proposed methods in order to correct and provide HR monitoring post-calibrated with high accuracy, raising further awareness of individual fitness in the daily application.

preprint2019arXiv

Drowsiness Detection for Office-based Workload with Mouse and Keyboard Data

Non-invasive devices involved in the detection of drowsiness generally include infrared camera and Electroencephalography (EEG), of which sometimes are constrained in an actual real-life scenario deployments and implementations such as in the working office environment. This study proposes a combination using the biometric features of keyboard and mouse movements and eye tracking during an office-based tasks to detect and evaluate drowsiness according to the self-report Karolinska sleepiness scale (KSS) questionnaire. Using machine learning models, the results demonstrate a correlation between the predicted KSS from the biometrics and the actual KSS from the user input, indicating the feasibility of evaluating the office workers' drowsiness level of the proposed approach.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.