Researcher profile

Apiwat Ditthapron

Apiwat Ditthapron contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - UnverifiedVerification L1Unclaimed author
2works
0followers
2topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2020arXiv

Improving Heart Rate Estimation on Consumer Grade Wrist-Worn Device Using Post-Calibration Approach

The technological advancement in wireless health monitoring through the direct contact of the skin allows the development of light-weight wrist-worn wearable devices to be equipped with different sensors such as photoplethysmography (PPG) sensors. However, the motion artifact (MA) is possible to occur during daily activities. In this study, we attempted to perform a post-calibration of the heart rate (HR) estimation during the three possible states of average daily activity (resting, \textcolor{red}{laying down}, and intense treadmill activity states) in 29 participants (130 minutes/person) on four popular wearable devices: Fitbit Charge HR, Apple Watch Series 4, TicWatch Pro, and Empatica E4. In comparison to the standard measurement (HR$_\text{ECG}$), HR provided by Fitbit Charge HR (HR$_\text{Fitbit}$) yielded the highest error of $3.26 \pm 0.34$ bpm in resting, $2.33 \pm 0.23$ bpm in \textcolor{red}{laying down}, $9.53 \pm 1.47$ bpm in intense treadmill activity states, and $5.02 \pm 0.64$ bpm in all states combined among the four chosen devices. Following our improving HR estimation model with rolling windows as feature (HR$_\text{R}$), the mean absolute error (MAE) was significantly reduced by $33.44\%$ in resting, $15.88\%$ in \textcolor{red}{laying down}, $9.55\%$ in intense treadmill activity states, and $18.73\%$ in all states combined. This demonstrates the feasibility of our proposed methods in order to correct and provide HR monitoring post-calibrated with high accuracy, raising further awareness of individual fitness in the daily application.

preprint2018arXiv

Deep Neural Networks with Weighted Averaged Overnight Airflow Features for Sleep Apnea-Hypopnea Severity Classification

Dramatic raising of Deep Learning (DL) approach and its capability in biomedical applications lead us to explore the advantages of using DL for sleep Apnea-Hypopnea severity classification. To reduce the complexity of clinical diagnosis using Polysomnography (PSG), which is multiple sensing platform, we incorporates our proposed DL scheme into one single Airflow (AF) sensing signal (subset of PSG). Seventeen features have been extracted from AF and then fed into Deep Neural Networks to classify in two studies. First, we proposed a binary classifications which use the cutoff indices at AHI = 5, 15 and 30 events/hour. Second, the multiple Sleep Apnea-Hypopnea Syndrome (SAHS) severity classification was proposed to classify patients into 4 groups including no SAHS, mild SAHS, moderate SAHS, and severe SAHS. For methods evaluation, we used a higher number of patients than related works to accommodate more diversity which includes 520 AF records obtained from the MrOS sleep study (Visit 2) database. We then applied the 10-fold cross-validation technique to get the accuracy, sensitivity and specificity. Moreover, we compared the results from our main classifier with other two approaches which were used in previous researches including the Support Vector Machine (SVM) and the Adaboost-Classification and Regression Trees (AB-CART). From the binary classification, our proposed method provides significantly higher performance than other two approaches with the accuracy of 83.46 %, 85.39 % and 92.69 % in each cutoff, respectively. For the multiclass classification, it also returns a highest accuracy of all approaches with 63.70 %.