Source author record

T. Sonoda

T. Sonoda appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

10works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

10 published item(s)

preprint2022arXiv

A new study of the $N=32$ and $N=34$ shell gap for Ti and V by the first high-precision MRTOF mass measurements at BigRIPS-SLOWRI

The atomic masses of $^{55}$Sc, $^{56,58}$Ti, and $^{56-59}$V have been determined using the high-precision multi-reflection time-of-flight technique. The radioisotopes have been produced at RIKEN's RIBF facility and delivered to the novel designed gas cell and multi-reflection system (ZD MRTOF), which has been recently commissioned downstream of the ZeroDegree spectrometer following the BigRIPS separator. For $^{56,58}$Ti and $^{56-59}$V the mass uncertainties have been reduced down to the order of $10\,\mathrm{keV}$, shedding new light on the $N=34$ shell effect in Ti and V isotopes by the first high-precision mass measurements of the critical species $^{58}$Ti and $^{59}$V. With the new precision achieved, we reveal the non-existence of the $N=34$ empirical two-neutron shell gaps for Ti and V, and the enhanced energy gap above the occupied $νp_{3/2}$ orbit is identified as a feature unique to Ca. We perform new Monte Carlo shell model calculations including the $νd_{5/2}$ and $νg_{9/2}$ orbits and compare the results with conventional shell model calculations, which exclude the $νg_{9/2}$ and the $νd_{5/2}$ orbits. The comparison indicates that the shell gap reduction in Ti is related to a partial occupation of the higher orbitals for the outer two valence neutrons at $N=34$.

preprint2013arXiv

A novel ion cooling trap for multi-reflection time-of-flight mass spectrograph

A radiofrequency quadrupole ion trap system for use with a multi-reflection time-of-flight mass spectrograph (MRTOF) for short-lived nuclei has been developed. The trap system consists of two different parts, an asymmetric taper trap and a flat trap. The ions are cooled to a sufficient small bunch for precise mass measurement with MRTOF in only 2 ms cooling time in the flat trap, then orthogonally ejected to the MRTOF for mass analysis. A trapping efficiency of ~27% for 23Na+ and ~5.1% for 7Li+ has been achieved.

preprint2013arXiv

Single-reference high-precision mass measurement with a multi-reflection time-of-flight mass spectrograph

A multi-reflection time-of-flight mass spectrograph, competitive with Penning trap mass spectrometers, has been built at RIKEN. We have performed a first online mass measurement, using 8Li+ (T1/2 = 838 ms). A new analysis method has been realized, with which, using only 12C+ references, the mass excess of 8Li was accurately determined to be 20947.6(15)(34) keV (dm/m = 6.6 x 10-7). The speed, precision and accuracy of this first online measurement exemplifies the potential for using this new type of mass spectrograph for precision measurements of short-lived nuclei.

preprint2012arXiv

An rf-carpet electrospray ion source to provide isobaric mass calibrants for trans-uranium elements

For trans-uranium elements, stable atomic isobars do not exist. In order to provide isobaric reference ions for the mass measurement of trans-uranium elements, an electrospray ion source (ESI) was combined with an rf-carpet to collect molecular ions efficiently. The rf-carpet allows for simplification of the pumping system to transport ions from the ESI to a precision mass analyzer. Molecular ions appropriate for isobaric references of trans-uranium elements were extracted from the rf-carpet and analyzed by a multi-reflection time-of-flight mass spectrograph (MRTOF-MS) with a resolving power of $\rm{R_m} \gtrsim100,000$.

preprint2012arXiv

Development of a resonant laser ionization gas cell for high-energy, short-lived nuclei

A new laser ion source configuration based on resonant photoionization in a gas cell has been developed at RIBF RIKEN. This system is intended for the future PArasitic RI-beam production by Laser Ion-Source (PALIS) project which will be installed at RIKEN's fragment separator, BigRIPS. A novel implementation of differential pumping, in combination with a sextupole ion beam guide (SPIG), has been developed. A few small scroll pumps create a pressure difference from 1000 hPa - 10^-3 Pa within a geometry drastically miniaturized compared to conventional systems. This system can utilize a large exit hole for fast evacuation times, minimizing the decay loss for short-lived nuclei during extraction from a buffer gas cell, while sufficient gas cell pressure is maintained for stopping high energy RI-beams. In spite of the motion in a dense pressure gradient, the photo-ionized ions inside the gas cell are ejected with an assisting force gas jet and successfully transported to a high-vacuum region via SPIG followed by a quadrupole mass separator. Observed behaviors agree with the results of gas flow and Monte Carlo simulations.

preprint2009arXiv

Dual Chamber Laser Ion Source at Lisol

A new type of the gas cell for the resonance ionization laser ion source at the Leuven Isotope Separator On Line (LISOL) has been developed and tested at off-line and on-line conditions. Two-step selective laser ionization is applied to produce purified beams of radioactive isotopes. The selectivity of the ion source has been increased by more than one order of magnitude by separation of the stopping and laser ionization regions. This allows to use electrical fields for further ion purification.

preprint2009arXiv

The Laser Ion Source Trap (LIST) coupled to a gas cell catcher

The proof of principle of the Laser Ion Source Trap (LIST) coupled to a gas cell catcher system has been demonstrated at the Leuven Isotope Separator On-Line (LISOL). The experiments were carried out by using the modified gas cell-based laser ion source and the SextuPole Ion Guide (SPIG). Element selective resonance laser ionization of neutral atoms was taking place inside the cold jet expanding out of the gas cell catcher. The laser path was oriented in longitudinal as well as transverse geometries with respect to the atoms flow. The enhancement of beam purity and the feasibility for in-source laser spectroscopy were investigated in off-line and on-line conditions.

preprint2006arXiv

An Ion Guide for the Production of a Low Energy Ion Beam of Daughter Products of $α$-Emitters

A new ion guide has been modeled and tested for the production of a low energy ($\approx$ 40 kV) ion beam of daughter products of alpha-emitting isotopes. The guide is designed to evacuate daughter recoils originating from the $α$-decay of a $^{233}$U source. The source is electroplated onto stainless steel strips and mounted along the inner walls of an ion guide chamber. A combination of electric fields and helium gas flow transport the ions through an exit hole for injection into a mass separator. Ion guide efficiencies for the extraction of $^{229}$Th$^{+}$ (0.06%), $^{221}$Fr$^{+}$ (6%), and $^{217}$At$^{+}$ (6%) beams have been measured. A detailed study of the electric field and gas flow influence on the ion guide efficiency is described for two differing electric field configurations.

preprint2002arXiv

Measurements of Cosmic-ray Low-energy Antiproton and Proton Spectra in a Transient Period of the Solar Field Reversal

The energy spectra of cosmic-ray low-energy antiprotons and protons have been measured by BESS in 1999 and 2000, during a period covering the solar magnetic field reversal. Based on these measurements, a sudden increase of the antiproton to proton flux ratio following the solar magnetic field reversal was observed, and it generally agrees with a drift model of the solar modulation.

preprint1999arXiv

Precision Measurement of Cosmic-Ray Antiproton Spectrum

The energy spectrum of cosmic-ray antiprotons has been measured in the range 0.18 to 3.56 GeV, based on 458 antiprotons collected by BESS in recent solar-minimum period. We have detected for the first time a distinctive peak at 2 GeV of antiprotons originating from cosmic-ray interactions with the interstellar gas. The peak spectrum is reproduced by theoretical calculations, implying that the propagation models are basically correct and that different cosmic-ray species undergo a universal propagation. Future BESS flights toward the solar maximum will help us to study the solar modulation and the propagation in detail and to search for primary antiproton components.