Source author record

T. Oku

Explore this author’s publications, collaborators and research topics. This catalog record has not been claimed by its author.

ResearcherUnclaimed source record

Catalog footprint

Research overview

3works
4topics
4close collaborators

Published work

3 publications

preprint2020arXiv

Development and application of a 3^3He Neutron Spin Filter at J-PARC

We are developing a neutron polarizer with polarized 3^3He gas, referred to as a 3^3He spin filter, based on the Spin Exchange Optical Pumping (SEOP) for polarized neutron scattering experiments at Materials and Life Science Experimental Facility (MLF) of Japan Proton Accelerator Research Complex (J-PARC). A 3^3He gas-filling station was constructed at J-PARC, and several 3^3He cells with long spin relaxation times have been fabricated using the gas-filling station. A laboratory has been prepared in the MLF beam hall for polarizing 3^3He cells, and compact pumping systems with laser powers of 30~W and 110~W, which can be installed onto a neutron beamline, have been developed. A 3^3He polarization of 85% was achieved at a neutron beamline by using the pumping system with the 110~W laser. Recently, the first user experiment utilizing the 3^3He spin filter was conducted, and there have been several more since then. The development and utilization of 3^3He spin filters at MLF of J-PARC are reported.

preprint2020arXiv

Transverse asymmetry of γγ rays from neutron-induced compound states of 140La{}^{140}{\rm La}

A correlation term σn⋅(kn×kγ){{ σ}_{n} }\cdot ({ k_{n}\times k_γ}) in the 139La(n⃗,γ){}^{139}{\rm La}(\vec{n},γ) reaction has been studied utilizing epithermal polarized neutrons and germanium detectors. The transverse asymmetry for single γγ-ray transition was measured to be 0.60±0.190.60\pm0.19 in the pp-wave resonance.

preprint2012arXiv

Neutron imaging detector based on the muPIC micro-pixel chamber

We have developed a prototype time-resolved neutron imaging detector employing the micro-pixel chamber (muPIC), a micro-pattern gaseous detector, coupled with a field programmable gate array-based data acquisition system for applications in neutron radiography at high-intensity neutron sources. The prototype system, with an active area of 10cm x 10cm and operated at a gas pressure of 2 atm, measures both the energy deposition (via time-over-threshold) and 3-dimensional track of each neutron-induced event, allowing the reconstruction of the neutron interaction point with improved accuracy. Using a simple position reconstruction algorithm, a spatial resolution of 349 +/- 36 microns was achieved, with further improvement expected. The detailed tracking allows strong rejection of background gamma-rays, resulting in an effective gamma sensitivity of 10^-12 or less, coupled with stable, robust neutron identification. The detector also features a time resolution of 0.6 microseconds.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.