Source author record

Steven Peil

Steven Peil appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

7works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

7 published item(s)

preprint2022arXiv

Tellurium Spectrometer for ${}^1\text{S}_0-{}^{1}\text{P}_1$ Transitions in Strontium and Other Alkaline-Earth Atoms

We measure the spectrum of tellurium-130 in the vicinity of the 461~nm ${}^1\text{S}_0-{}^{1}\text{P}_1$ cycling transition in neutral strontium, a popular element for atomic clocks, quantum information, and quantum-degenerate gases. The lack of hyperfine structure in tellurium results in a spectral density of transitions nearly 50 times lower than that available in iodine, making use of tellurium as a laser-frequency reference challenging. By frequency-offset locking two lasers, we generate the large frequency shifts required to span the difference between a tellurium line and the ${}^1\text{S}_0-{}^1\text{P}_1$ resonance in strontium or other alkaline-earth atom. The resulting laser architecture is long-term frequency stable, widely tunable, and optimizes available laser power. The versatility of the system is demonstrated by using it to quickly switch between any strontium isotope in a magneto-optical trap and by adapting it to spectroscopy on a thermal beam with a different alkaline-earth atom.

preprint2020arXiv

Competition between Factors Determining Bright versus Dark Atomic States within a Laser Mode

We observe bimodal fluorescence patterns from atoms in a fast atomic beam when the laser excitation occurs in the presence of a magnetic field and the atoms sample only a portion of the laser profile. The behavior is well explained by competition between the local intensity of the laser, which tends to generate a coherent-population-trapping (CPT) dark state in the $J=1$ to $J'=0$ system, and the strength of an applied magnetic field that can frustrate the CPT process. This work is relevant for understanding and optimizing the detection process for clocks or other coherent systems utilizing these transitions and could be applicable to in situ calibration of the laser-atom interaction, such as the strength of the magnetic field or laser intensity at a specific location.

preprint2016arXiv

The USNO rubidium fountains

Four rubidium fountains at the U.S. Naval Observatory (USNO) have been in operation for 4.5 years. Each fountain has demonstrated periods of stability marked by Total or Theo deviation below 10^-16. Occasional frequency changes, on order of 1.5 times per year per fountain, introduce deviations from white-frequency noise behavior. Averaged together, the four fountains form an ensemble with a white-frequency noise level of 10^-13 and excellent long-term stability as compared to the primary frequency standards contributing to TAI. Progress on using the clocks at USNO for improving limits on coupling of fundamental constants to gravity by measuring the universality of the gravitational redshift for different types of clocks is discussed.

preprint2014arXiv

Analysis of atom-interferometer clocks

We analyze the nature and performance of clocks formed by stabilizing an oscillator to the phase difference between two paths of an atom interferometer. The phase evolution has been modeled as being driven by the proper-time difference between the two paths, although it has an ambiguous origin in the non-relativistic limit and it requires a full quantum-field-theory treatment in the general case. We present conditions for identifying deviations from the non-relativistic limit as a way of testing the proper-time driven phase evolution model. We show that the system performance belies the premise that an atom-interferometer clock is referenced to a divided-down Compton oscillation, and we suggest that this implies there is no physical oscillation at the Compton frequency.

preprint2014arXiv

Evaluation of Long Term Performance of Continuously Running Atomic Fountains

An ensemble of rubidium atomic fountain clocks has been put into operation at the U.S. Naval Observatory (USNO). These fountains are used as continuous clocks in the manner of commercial cesium beams and hydrogen masers for the purpose of improved timing applications. Four fountains have been in operation for more than two years and are included in the ensemble used to generate the USNO master clock. Individual fountain performance is characterized by a white-frequency noise level below $2\times 10^{-13}$ and fractional-frequency stability routinely reaching the low $10^{-16}$s. The highest performing pair of fountains exhibits stability consistent with each fountain integrating as white frequency noise, with Allan deviation surpassing $6\times 10^{-17}$ at $10^7$~s, and with no relative drift between the fountains at the level of $7.5 \times 10^{-19}$/day. As an ensemble, the fountains generate a timescale with white-frequency noise level of $1\times 10^{-13}$ and long-term frequency stability consistent with zero drift relative to the world's primary standards at $1 \times 10^{-18}$/day. The rubidium fountains are reported to the BIPM as continuously running clocks, as opposed to secondary standards, the only cold-atom clocks so reported. Here we further characterize the performance of the individual fountains and the ensemble during the first two years in an operational environment, presenting the first look at long-term continuous behavior of fountain clocks.

preprint2013arXiv

Proposed test of relative phase as hidden variable in quantum mechanics

We consider the possibility that the relative phase in quantum mechanics plays a role in determining measurement outcome and could therefore serve as a "hidden" variable. The Born rule for measurement equates the probability for a given outcome with the absolute square of the coefficient of the basis state, which by design removes the relative phase from the formulation. The value of this phase at the moment of measurement naturally averages out in an ensemble, which would prevent any dependence from being observed, and we show that conventional frequency-spectroscopy measurements on discrete quantum systems cannot be imposed at a specific phase due to a straightforward uncertainty relation. We lay out general conditions for imposing measurements at a specific value of the relative phase so that the possibility of its role as a hidden variable can be tested, and we discuss implementation for the specific case of an atomic two-state system with laser-induced fluorescence for measurement.

preprint2013arXiv

Tests of local position invariance using continuously running atomic clocks

Tests of local position invariance (LPI) made by comparing the relative redshift of atomic clocks based on different atoms have been carried out for a variety of pairs of atomic species. In most cases, several absolute frequency measurements per year are used to look for an annual signal, resulting in tests that can span on order of a decade. By using the output of continuously running clocks, we carry out LPI tests with comparable or higher precision after less than 1.5 years. These include new measurements of the difference in redshift anomalies β for hyperfine transitions in Rb87 and Cs133 and in H and Cs133 and a measurement comparing Rb87 and H, resulting in a stringent limit on LPI, β(Rb) - β(H)=(-2.7 +/- 4.9) x 10^(-7). The method of making these measurements for continuous clocks is discussed.