Researcher profile

Christopher R. Ekstrom

Christopher R. Ekstrom contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - UnverifiedVerification L1Unclaimed author
3works
0followers
1topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2014arXiv

Analysis of atom-interferometer clocks

We analyze the nature and performance of clocks formed by stabilizing an oscillator to the phase difference between two paths of an atom interferometer. The phase evolution has been modeled as being driven by the proper-time difference between the two paths, although it has an ambiguous origin in the non-relativistic limit and it requires a full quantum-field-theory treatment in the general case. We present conditions for identifying deviations from the non-relativistic limit as a way of testing the proper-time driven phase evolution model. We show that the system performance belies the premise that an atom-interferometer clock is referenced to a divided-down Compton oscillation, and we suggest that this implies there is no physical oscillation at the Compton frequency.

preprint2014arXiv

Evaluation of Long Term Performance of Continuously Running Atomic Fountains

An ensemble of rubidium atomic fountain clocks has been put into operation at the U.S. Naval Observatory (USNO). These fountains are used as continuous clocks in the manner of commercial cesium beams and hydrogen masers for the purpose of improved timing applications. Four fountains have been in operation for more than two years and are included in the ensemble used to generate the USNO master clock. Individual fountain performance is characterized by a white-frequency noise level below $2\times 10^{-13}$ and fractional-frequency stability routinely reaching the low $10^{-16}$s. The highest performing pair of fountains exhibits stability consistent with each fountain integrating as white frequency noise, with Allan deviation surpassing $6\times 10^{-17}$ at $10^7$~s, and with no relative drift between the fountains at the level of $7.5 \times 10^{-19}$/day. As an ensemble, the fountains generate a timescale with white-frequency noise level of $1\times 10^{-13}$ and long-term frequency stability consistent with zero drift relative to the world's primary standards at $1 \times 10^{-18}$/day. The rubidium fountains are reported to the BIPM as continuously running clocks, as opposed to secondary standards, the only cold-atom clocks so reported. Here we further characterize the performance of the individual fountains and the ensemble during the first two years in an operational environment, presenting the first look at long-term continuous behavior of fountain clocks.

preprint2013arXiv

Tests of local position invariance using continuously running atomic clocks

Tests of local position invariance (LPI) made by comparing the relative redshift of atomic clocks based on different atoms have been carried out for a variety of pairs of atomic species. In most cases, several absolute frequency measurements per year are used to look for an annual signal, resulting in tests that can span on order of a decade. By using the output of continuously running clocks, we carry out LPI tests with comparable or higher precision after less than 1.5 years. These include new measurements of the difference in redshift anomalies β for hyperfine transitions in Rb87 and Cs133 and in H and Cs133 and a measurement comparing Rb87 and H, resulting in a stringent limit on LPI, β(Rb) - β(H)=(-2.7 +/- 4.9) x 10^(-7). The method of making these measurements for continuous clocks is discussed.