Steffen Greilich

Steffen Greilich appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

7works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

7 published item(s)

preprint2019arXiv

Impact of new ICRU90 key data on stopping-power ratios and beam quality correction factors for carbon ion beams

The recent update of dosimetric key data by the `International Commission on Radiation Units and Measurements' impacts the computation of beam quality correction factors $k_Q$ via several changes, e.g. for the mean excitation energies, $I$, which enters the stopping power computation for water and air, the computation procedure itself, the average energy expended in the production of an ion pair in air, $W/e$, as well as chamber perturbation factors for Cobalt-60. An accurate assessment of water-to-air stopping-power ratio, $s_{\rm w,air}$, in reference conditions with new recommendation is necessary to update the dosimetry protocols for carbon ion beams. The new ICRU90 key data were considered for computation of $s_{\rm w,air}$ for carbon ion beams using Monte Carlo transport simulations for a number of reference conditions, namely monoenergetic carbon ion beams with range in water from 3 to 30\,cm and Spread-Out Bragg peaks (SOBPs) of different widths and depths in water. New recommendations for $s_{\rm w,air}$ are presented, namely 1.1247 for the reference condition of 1\,g\,cm$^{-2}$ depth for monoenergetic carbon ion beams and 1.1274 at the center of physically-optimized SOBPs. The recommendation of a constant value (1.126) represents the stopping-power ratio within a 0.3\,\% variation of $s_{\rm w,air}$ for the different reference conditions. The impact of these new $s_{\rm w,air}$ values and the updated key data on the $k_Q$ for carbon ion beams was evaluated in a second step. The changes agree very well with experimental data for the case of cylindrical ionization chambers, but larger discrepancies are observed for plate-parallel ionization chambers.

preprint2016arXiv

Range prediction for tissue mixtures based on dual-energy CT

The use of dual-energy CT (DECT) potentially decreases range uncertainties in proton and ion therapy treatment planning via determination of the involved physical target quantities. For eventual clinical application, the correct treatment of tissue mixtures and heterogeneities is an essential feature, as they naturally occur within a patient's CT. Here, we present how existing methods for DECT-based ion-range prediction can be modified in order to incorporate proper mixing behavior on several structural levels. Our approach is based on the factorization of the stopping-power ratio into the relative electron density and the relative stopping number. The latter is confined for tissue between about 0.95 and 1.02 at a therapeutic beam energy of 200 MeV/u and depends on the I-value. We show that convenient mixing and averaging properties arise by relating the relative stopping number to the relative cross section obtained by DECT. From this, a maximum uncertainty of the stopping-power ratio prediction below 1% is suggested for arbitrary mixtures of human body tissues.

preprint2015arXiv

An anthropomorphic multimodality (CT/MRI) phantom prototype for end-to-end tests in radiation therapy

With the increasing complexity of external beam therapy, so-called "end-to-end" tests are intended to cover all steps from therapy planning to follow-up to fulfill the high demands on quality assurance. As magnetic resonance imaging (MRI) gains growing importance in the treatment process and established phantoms (such as the Alderson head) cannot be used for those tests, novel multimodality phantoms have to be developed. Here, we present a feasibility study for such a customizable multimodality head phantom. We used a set of patient CT images as the basis for the anthropomorphic head shape. The recipient - consisting of an epoxy resin - was produced using rapid prototyping (3D printing). The phantom recipient includes a nasal air cavity, two soft tissues volumes and cranial bone. Additionally a spherical tumor volume was positioned in the center. The volumes were filled with dipotassium phosphate-based cranial bone surrogate, agarose gel, and distilled water. The tumor volume was filled with normoxic dosimetric gel. The entire workflow of radiation therapy including a clinical proton irradiation could be successfully applied to the phantom. CT measurements revealed Hounsfield units agreeing with reference values for all surrogates. The MRI contrasts corresponded to the expectations on the phantom materials except for the bone surrogate providing an undesirably high signal intensity. The dose verification by T2-weighted read out of the polymerization gel dosimeter could successfully show a correct plan delivery in terms of particle range.

preprint2015arXiv

Single-grain dose-distribution measurements by optically stimulated luminescence using an integrated EMCCD-based system

We report on the feasibility of assessing single-grain dose-distributions by using an EMCCD-based imaging system with complementary analysis software. Automated image-processing was successfully applied to compensate sample motion and for automated grain identification. Following a dose recovery test, 74 % of the grains were recognized successfully, and 44 % exhibited a suitable OSL dose response behavior to interpolate an equivalent dose value and a central dose recovery ratio of 1.038 was obtained.

preprint2014arXiv

Absorbed Dose in Ion Beams: Comparison of Ionisation and Fluence-based Measurements

A direct comparison measurement of fluorescent nuclear track detectors (FNTDs) and a thimble ionisation chamber is presented. Irradiations were performed using monoenergetic protons (142.66 MeV, 3*10^6 1/cm2) and carbon ions (270.55 MeV/u, 3*10^6 1/cm2). It was found that absorbed dose to water values as determined by fluence measurements using FNTDs are, in case of protons, in good agreement (2.4 %) with ionization chamber measurements, if slower protons and Helium secondaries were accounted for by an effective stopping power. For carbon, however, a significant discrepancy of 4.5 % was seen, which could not be explained by fragmentation, uncertainties or experimental design. The results rather suggest a W-value of 32.10 eV +/- 2.6 %. Additionally, the abundance of secondary protons expected from Monte-Carlo transport simulation was not observed.

preprint2014arXiv

Quantitative read-out of Al2O3:C,Mg-based fluorescent nuclear track detectors using a commercial confocal microscope

Fluorescent nuclear track detectors (FNTD) show great potential for applications in ion-beam therapy research, such as dosimetry, advanced beam characterization, in-vivo use or as radiobiological assay. A essential feature of FNTDs is their ability to assess the energy loss of single ions yielding for example LET estimations. This article describes the basic characterisations of FNTDs and our read-out system (a Zeiss LSM710 confocal laser scanning microscope) to enable quantative measurements of energy loss.

preprint2013arXiv

Ion track reconstruction in 3D using alumina-based fluorescent nuclear track detectors

Fluorescent nuclear track detectors (FNTDs) based on Al2O3:C,Mg single crystal combined with confocal microscopy provide 3D information on ion tracks with a resolution only limited by light diffraction. FNTDs are also ideal substrates to be coated with cells to engineer cell-fluorescent ion track hybrid detectors. This radiobiological tool enables a novel platform linking cell responses to physical dose deposition on a sub-cellular level in proton and heavy ion therapies. To achieve spatial correlation between single ion hits in the cell coating and its biological response the ion traversals have to be reconstructed in 3D using the depth information gained by the FNTD read-out. FNTDs were coated with a confluent human lung adenocarcinoma epithelial cell layer. Carbon ion irradiation of the hybrid detector was performed perpendicular and angular to the detector surface. In-situ imaging of the fluorescently labeled cell layer and the FNTD was performed in a sequential read-out. Making use of the trajectory information provided by the FNTD the accuracy of 3D track reconstruction of single particles traversing the hybrid detector was studied. The accuracy is strongly influenced by the irradiation angle and therefore by complexity of the FNTD signal. Perpendicular irradiation results in highest accuracy with error of smaller than 0.10°. The ability of FNTD technology to provide accurate 3D ion track reconstruction makes it a powerful tool for radiobiological investigations in clinical ion beams, either being used as a substrate to be coated with living tissue or being implanted in vivo.