Source author record

St. Falke

St. Falke appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

7works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

7 published item(s)

preprint2014arXiv

A transportable strontium optical lattice clock

We report on a transportable optical clock, based on laser-cooled strontium atoms trapped in an optical lattice. The experimental apparatus is composed of a compact source of ultra-cold strontium atoms including a compact cooling laser set-up and a transportable ultra-stable laser for interrogating the optical clock transition. The whole setup (excluding electronics) fits within a volume of less than 2 m$^3$. The high degree of operation reliability of both systems allowed the spectroscopy of the clock transition to be performed with 10 Hz resolution. We estimate an uncertainty of the clock of $7\times10^{-15}$.

preprint2014arXiv

Direct comparison of optical lattice clocks with an intercontinental baseline of 9 000 km

We have demonstrated a direct frequency comparison between two $^{87}{\rm Sr}$ lattice clocks operated in intercontinentally separated laboratories in real time. Two-way satellite time and frequency transfer technique based on the carrier phase was employed for a direct comparison with a baseline of 9 000 km between Japan and Germany. A clock comparison was achieved for 83 640 s resulting in a fractional difference of $(1.1\pm1.6) \times 10^{-15}$, where the statistical part is the biggest contribution to the uncertainty. This measurement directly confirms the agreement of the two optical clocks on an intercontinental scale.

preprint2012arXiv

Providing 1E-16 short-term stability of a 1.5 μm laser to optical clocks

We report on transferring 1E-16-level fractional frequency stability of a "master laser" operated at 1.5 μm to a "slave laser" operated at 698 nm, using a femtosecond fiber comb as transfer oscillator. With the 698 nm laser, the 1S_0 - 3P_0 clock transition of 87Sr was resolved to a Fourier-limited line width of 1.5 Hz (before: 10 Hz). Potential noise sources contributed by the frequency comb are discussed in detail.

preprint2011arXiv

The 87-Sr optical frequency standard at PTB

With 87-Sr atoms confined in a one dimensional optical lattice, the frequency of the optical clock transition 5s^2 ^1S_0 - 5s5p ^3P_0 has been determined to be 429 228 004 229 872.9(5) Hz. The transition frequency was measured with the help of a fs-frequency comb against one of PTB's H-masers whose frequency was measured simultaneously by the PTB Cs fountain clock CSF1. The Sr optical frequency standard contributes with a fractional uncertainty of 1.5 10^-16 to the total uncertainty. The agreement of the measured transition frequency with previous measurements at other institutes supports the status of this transition as secondary representation of the second with the currently smallest uncertainty.

preprint2008arXiv

Transport of a quantum degenerate heteronuclear Bose-Fermi mixture in a harmonic trap

We report on the transport of mixed quantum degenerate gases of bosonic 87Rb and fermionic 40K in a harmonic potential provided by a modified QUIC trap. The samples are transported over a distance of 6 mm to the geometric center of the anti-Helmholtz coils of the QUIC trap. This transport mechanism was implemented by a small modification of the QUIC trap and is free of losses and heating. It allows all experiments using QUIC traps to use the highly homogeneous magnetic fields that can be created in the center of a QUIC trap and improves the optical access to the atoms, e.g., for experiments with optical lattices. This mechanism may be cascaded to cover even larger distances for applications with quantum degenerate samples.

preprint2005arXiv

Study of coupled states for the (4s^{2})^{1}S + (4s4p)^{3}P asymptote of Ca_{2}

The coupled states A^{1}Σ_{u}^{+} (^{1}D +}1}S), c^{3}Π_{u} (^{3}P + ^{1}S) and a^{3}Σ_{u}^{+} (^{3}P +}1}S) of the calcium dimer are investigated in a laser induced fluorescence experiment combined with high-resolution Fourier-transform spectroscopy. A global deperturbation analysis of the observed levels, considering a model, which is complete within the subspace of relevant neighboring states, is performed using the Fourier Grid Hamiltonian method. We determine the potential energy curve of the A^{1}Σ_{u}^{+} and c^{3}Π_{u} states and the strengths of the couplings between them. The c^{3}Π_{u} and \as states are of particular importance for the description of collisional processes between calcium atoms in the ground state ^{1}S_{0} and excited state ^{3}P_{1} applied in studies for establishing an optical frequency standard with Ca.

preprint2003arXiv

Optical Manipulation of Long-range Interactions at the 3s+3p Asymptote of Na$_2$

We investigate the influence of a laser field, which is near-resonant to the atomic sodium 3$^2$P$_{1/2}$ $\to$ 3$^2$D$_{3/2}$ transition, on the last bound levels of the A$^1Σ^+_u$ state in Na$_2$. In a molecular beam experiment level shifts up to $\approx$ 100 MHz and light induced line broadenings were observed using an optical double resonance excitation scheme. Moreover, the coupling laser can reduce the number of bound levels of the A state by one or more units, which effectively means that in the picture of a collision of a 3$^2$S$_{1/2}$ and a 3$^2$P$_{1/2}$-atom the scattering phase is altered by more than $π$. The observed effects are interpreted as light induced couplings of the A$^1Σ^+_u$ state, which correlates to the 3s$_{1/2}$+3p$_{1/2}$ asymptote, to the $4^1Σ^+_g$ and $2^1Π_g$ states at the 3s$_{1/2}$+3d$_{3/2}$ asymptote. We performed multi-channel calculations, applying the mapped Fourier grid method, which reproduce our experimentally observed level shifts well.