Source author record

U. Sterr

U. Sterr appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

19works
8topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

19 published item(s)

preprint2020arXiv

Long term measurement of the $^{87}$Sr clock frequency at the limit of primary Cs clocks

We report on a series of 42 measurements of the transition frequency of the 429~THz (5s$^2$)~$^1$S$_0$--(5s5p)~$^3$P$_0$ line in $^{87}$Sr taken over three years from 2017 to 2019. They have been performed at the Physikalisch-Technische Bundesanstalt (PTB) between the laboratory strontium lattice clock and the primary caesium fountain clocks CSF1 and CSF2. The length of each individual measurement run has been extended by use of a hydrogen maser as flywheel to improve the statistical uncertainty given by the Cs clocks. We determine an averaged transition frequency of $429\:228\:004\:229\:873.00(0.07)$~Hz with $1.5\times10^{-16}$ fractional uncertainty, at the limit of the current realization of the unit hertz. Analysis of the data provides an improved limit on the coupling of the gravitational potential of the Sun to the proton--electron mass ratio $μ$, and confirms the limits on its temporal drift.

preprint2019arXiv

Search for transient variations of the fine structure constant and dark matter using fiber-linked optical atomic clocks

We search for transient variations of the fine structure constant using data from a European network of fiber-linked optical atomic clocks. By searching for coherent variations in the recorded clock frequency comparisons across the network, we significantly improve the constraints on transient variations of the fine structure constant. For example, we constrain the variation in alpha to <5*10^-17 for transients of duration 10^3 s. This analysis also presents a possibility to search for dark matter, the mysterious substance hypothesised to explain galaxy dynamics and other astrophysical phenomena that is thought to dominate the matter density of the universe. At the current sensitivity level, we find no evidence for dark matter in the form of topological defects (or, more generally, any macroscopic objects), and we thus place constraints on certain potential couplings between the dark matter and standard model particles, substantially improving upon the existing constraints, particularly for large (>~10^4 km) objects.

preprint2016arXiv

Development of a strontium optical lattice clock for the SOC mission on the ISS

The ESA mission "Space Optical Clock" project aims at operating an optical lattice clock on the ISS in approximately 2023. The scientific goals of the mission are to perform tests of fundamental physics, to enable space-assisted relativistic geodesy and to intercompare optical clocks on the ground using microwave and optical links. The performance goal of the space clock is less than $1 \times 10^{-17}$ uncertainty and $1 \times 10^{-15} τ^{-1/2}$ instability. Within an EU-FP7-funded project, a strontium optical lattice clock demonstrator has been developed. Goal performances are instability below $1 \times 10^{-15} τ^{-1/2}$ and fractional inaccuracy $5 \times 10^{-17}$. For the design of the clock, techniques and approaches suitable for later space application are used, such as modular design, diode lasers, low power consumption subunits, and compact dimensions. The Sr clock apparatus is fully operational, and the clock transition in $^{88}$Sr was observed with linewidth as small as 9 Hz.

preprint2016arXiv

Realization of a time-scale with an accurate optical lattice clock

Optical clocks are not only powerful tools for prime fundamental research, but are also deemed for the re-definition of the SI base unit second as they now surpass the performance of caesium atomic clocks in both accuracy and stability by more than an order of magnitude. However, an important obstacle in this transition has so far been the limited reliability of the optical clocks that made a continuous realization of a timescale impractical. In this paper, we demonstrate how this situation can be resolved and that a timescale based on an optical clock can be established that is superior to one based on even the best caesium fountain clocks. The paper also gives further proof of the international consistency of strontium lattice clocks on the $10^{-16}$ accuracy level, which is another prerequisite for a change in the definition of the second.

preprint2015arXiv

A clock network for geodesy and fundamental science

Leveraging the unrivaled performance of optical clocks in applications in fundamental physics beyond the standard model, in geo-sciences, and in astronomy requires comparing the frequency of distant optical clocks truthfully. Meeting this requirement, we report on the first comparison and agreement of fully independent optical clocks separated by 700 km being only limited by the uncertainties of the clocks themselves. This is achieved by a phase-coherent optical frequency transfer via a 1415 km long telecom fiber link that enables substantially better precision than classical means of frequency transfer. The fractional precision in comparing the optical clocks of three parts in $10^{17}$ was reached after only 1000 s averaging time, which is already 10 times better and more than four orders of magnitude faster than with any other existing frequency transfer method. The capability of performing high resolution international clock comparisons paves the way for a redefinition of the unit of time and an all-optical dissemination of the SI-second.

preprint2015arXiv

Development of a strontium optical lattice clock for the SOC mission on the ISS

Ultra-precise optical clocks in space will allow new studies in fundamental physics and astronomy. Within an European Space Agency (ESA) program, the Space Optical Clocks (SOC) project aims to install and to operate an optical lattice clock on the International Space Station (ISS) towards the end of this decade. It would be a natural follow-on to the ACES mission, improving its performance by at least one order of magnitude. The payload is planned to include an optical lattice clock, as well as a frequency comb, a microwave link, and an optical link for comparisons of the ISS clock with ground clocks located in several countries and continents. Within the EU-FP7-SPACE-2010-1 project no. 263500, during the years 2011-2015 a compact, modular and robust strontium lattice optical clock demonstrator has been developed. Goal performance is a fractional frequency instability below 1x10^{-15}, tau^{-1/2} and a fractional inaccuracy below 5x10^{-17}. Here we describe the current status of the apparatus' development, including the laser subsystems. Robust preparation of cold {88}^Sr atoms in a second stage magneto-optical trap (MOT) is achieved.

preprint2014arXiv

A transportable strontium optical lattice clock

We report on a transportable optical clock, based on laser-cooled strontium atoms trapped in an optical lattice. The experimental apparatus is composed of a compact source of ultra-cold strontium atoms including a compact cooling laser set-up and a transportable ultra-stable laser for interrogating the optical clock transition. The whole setup (excluding electronics) fits within a volume of less than 2 m$^3$. The high degree of operation reliability of both systems allowed the spectroscopy of the clock transition to be performed with 10 Hz resolution. We estimate an uncertainty of the clock of $7\times10^{-15}$.

preprint2012arXiv

A sub-40 mHz linewidth laser based on a silicon single-crystal optical cavity

State-of-the-art optical oscillators based on lasers frequency stabilized to high finesse optical cavities are limited by thermal noise that causes fluctuations of the cavity length. Thermal noise represents a fundamental limit to the stability of an optical interferometer and plays a key role in modern optical metrology. We demonstrate a novel design to reduce the thermal noise limit for optical cavities by an order of magnitude and present an experimental realization of this new cavity system, demonstrating the most stable oscillator of any kind to date. The cavity spacer and the mirror substrates are both constructed from single crystal silicon and operated at 124 K where the silicon thermal expansion coefficient is zero and the silicon mechanical loss is small. The cavity is supported in a vibration-insensitive configuration, which, together with the superior stiffness of silicon crystal, reduces the vibration related noise. With rigorous analysis of heterodyne beat signals among three independent stable lasers, the silicon system demonstrates a fractional frequency stability of 1E-16 at short time scales and supports a laser linewidth of <40 mHz at 1.5 μm, representing an optical quality factor of 4E15.

preprint2012arXiv

Providing 1E-16 short-term stability of a 1.5 μm laser to optical clocks

We report on transferring 1E-16-level fractional frequency stability of a "master laser" operated at 1.5 μm to a "slave laser" operated at 698 nm, using a femtosecond fiber comb as transfer oscillator. With the 698 nm laser, the 1S_0 - 3P_0 clock transition of 87Sr was resolved to a Fourier-limited line width of 1.5 Hz (before: 10 Hz). Potential noise sources contributed by the frequency comb are discussed in detail.

preprint2012arXiv

The Space Optical Clocks Project: Development of high-performance transportable and breadboard optical clocks and advanced subsystems

The use of ultra-precise optical clocks in space ("master clocks") will allow for a range of new applications in the fields of fundamental physics (tests of Einstein's theory of General Relativity, time and frequency metrology by means of the comparison of distant terrestrial clocks), geophysics (mapping of the gravitational potential of Earth), and astronomy (providing local oscillators for radio ranging and interferometry in space). Within the ELIPS-3 program of ESA, the "Space Optical Clocks" (SOC) project aims to install and to operate an optical lattice clock on the ISS towards the end of this decade, as a natural follow-on to the ACES mission, improving its performance by at least one order of magnitude. The payload is planned to include an optical lattice clock, as well as a frequency comb, a microwave link, and an optical link for comparisons of the ISS clock with ground clocks located in several countries and continents. Undertaking a necessary step towards optical clocks in space, the EU-FP7-SPACE-2010-1 project no. 263500 (SOC2) (2011-2015) aims at two "engineering confidence", accurate transportable lattice optical clock demonstrators having relative frequency instability below 1\times10^-15 at 1 s integration time and relative inaccuracy below 5\times10^-17. This goal performance is about 2 and 1 orders better in instability and inaccuracy, respectively, than today's best transportable clocks. The devices will be based on trapped neutral ytterbium and strontium atoms. One device will be a breadboard. The two systems will be validated in laboratory environments and their performance will be established by comparison with laboratory optical clocks and primary frequency standards. In this paper we present the project and the results achieved during the first year.

preprint2011arXiv

Remote frequency measurement of the 1S0-3P1 transition in laser cooled Mg-24

We perform Ramsey-Bordé spectroscopy on laser-cooled magnesium atoms in free fall to measure the 1S0 \rightarrow 3P1 intercombination transition frequency. The measured value of 655 659 923 839 730 (48) Hz is consistent with our former atomic beam measurement (Friebe et al 2008 Phys. Rev. A 78 033830). We improve upon the fractional accuracy of the previous measurement by more than an order of magnitude to 7e-14. The magnesium frequency standard was referenced to a fountain clock of the Physikalisch-Technische Bundesanstalt (PTB) via a phase-stabilized telecom fiber link and its stability was characterized for interrogation times up to 8000 s. The high temperature of the atomic ensemble leads to a systematic shift due to the motion of atoms across the spectroscopy beams. In our regime, this leads to a counterintuitive reduction of residual Doppler shift with increasing resolution. Our theoretical model of the atom-light interaction is in agreement with the observed effect and allows us to quantify its contribution in the uncertainty budget.

preprint2011arXiv

The 87-Sr optical frequency standard at PTB

With 87-Sr atoms confined in a one dimensional optical lattice, the frequency of the optical clock transition 5s^2 ^1S_0 - 5s5p ^3P_0 has been determined to be 429 228 004 229 872.9(5) Hz. The transition frequency was measured with the help of a fs-frequency comb against one of PTB's H-masers whose frequency was measured simultaneously by the PTB Cs fountain clock CSF1. The Sr optical frequency standard contributes with a fractional uncertainty of 1.5 10^-16 to the total uncertainty. The agreement of the measured transition frequency with previous measurements at other institutes supports the status of this transition as secondary representation of the second with the currently smallest uncertainty.

preprint2010arXiv

Hyper-Ramsey Spectroscopy of Optical Clock Transitions

We present non-standard optical Ramsey schemes that use pulses individually tailored in duration, phase, and frequency to cancel spurious frequency shifts related to the excitation itself. In particular, the field shifts and their uncertainties of Ramsey fringes can be radically suppressed (by 2-4 orders of magnitude) in comparison with the usual Ramsey method (using two equal pulses) as well as with single-pulse Rabi spectroscopy. Atom interferometers and optical clocks based on two-photon transitions, heavily forbidden transitions, or magnetically induced spectroscopy could significantly benefit from this method. In the latter case these frequency shifts can be suppressed considerably below a fractional level of 10^{-17}. Moreover, our approach opens the door for the high-precision optical clocks based on direct frequency comb spectroscopy.

preprint2009arXiv

Collisional losses, decoherence, and frequency shifts in optical lattice clocks with bosons

We have quantified collisional losses, decoherence and the collision shift in a one-dimensional optical lattice clock with bosonic 88Sr. The lattice clock is referenced to the highly forbidden transition 1S0 - 3P0 at 698 nm, which becomes weakly allowed due to state mixing in a homogeneous magnetic field. We were able to quantify three decoherence coefficients, which are due to dephasing collisions, inelastic collisions between atoms in the upper and lower clock state, and atoms in the upper clock state only. Based on the measured coefficients, we determine the operation parameters at which a 1D-lattice clock with 88Sr shows no degradation due to collisions on the relative accuracy level of 10-16.

preprint2009arXiv

Compensation of Field-Induced Frequency Shifts in Ramsey Spectroscopy of Optical Clock Transitions

We have extended Ramsey spectroscopy by stepping the probe frequency during the two Ramsey excitation pulses to compensate frequency shifts induced by the excitation itself. This makes precision Ramsey spectroscopy applicable even for transitions that have Stark and Zeeman shifts comparable to the spectroscopic resolution. The method enables a new way to evaluate and compensate key frequency shifts, which benefits in particular, optical clocks based on magnetic field-induced, spectroscopy, two-photon transitions, or heavily forbidden transitions.

preprint2009arXiv

Optical frequency transfer via 146 km fiber link with 10^{-19} relative accuracy

We demonstrate the long-distance transmission of an ultra-stable optical frequency derived directly from a state-of-the-art optical frequency standard. Using an active stabilization system we deliver the frequency via a 146 km long underground fiber link with a fractional instability of 3*10^{-15} at 1 s, which is close to the theoretical limit for our transfer experiment. The relative uncertainty for the transfer is below 1*10^{-19} after 30 000 seconds. Tests with a very short fiber show that noise in our stabilization system contributes fluctuations which are two orders of magnitude lower, namely 3*10^{-17} at 1 s, reaching 10^{-20} after 4000 s.

preprint2008arXiv

Interrogation laser for a strontium lattice clock

We report on the setup and characterization of a 698 nm master-slave diode laser system to probe the 1S0-3P0 clock transition of strontium atoms confined in a one-dimensional optical lattice. A linewidth in the order of around 100 Hz of the laser system has been measured with respect to an ultrastable 657 nm diode laser with 1 Hz linewidth using a femtosecond fiber comb as transfer oscillator. The laser has been used to measure the magnetically induced 1S0-3P0 clock transition in 88Sr where a linewidth of 165 Hz has been observed. The transfer oscillator method provides a virtual beat signal between the two diode lasers that has been used to phase lock the 698 nm laser to the 1 Hz linewidth laser at 657 nm, transferring its stability to the 698 nm laser system.

preprint2001arXiv

Doppler cooling and trapping on forbidden transitions

Ultracold atoms at temperatures close to the recoil limit have been achieved by extending Doppler cooling to forbidden transitions. A cloud of ^40Ca atoms has been cooled and trapped to a temperature as low as 6 μK by operating a magneto-optical trap on the spin-forbidden intercombination transition. Quenching the long-lived excited state with an additional laser enhanced the scattering rate by a factor of 15, while a high selectivity in velocity was preserved. With this method more than 10% of pre-cooled atoms from a standard magneto-optical trap have been transferred to the ultracold trap. Monte-Carlo simulations of the cooling process are in good agreement with the experiments.