Researcher profile

Sourav Mukhopadhyay

Sourav Mukhopadhyay contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
5topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2022arXiv

A wide swing charge sensitive amplifier for a prototype Si-W EM calorimeter

A wide swing charge sensitive amplifier (CSA) has been developed, as a part of a front-end electronics (FEE) readout ASIC, for a prototype silicon tungsten (Si-W) based electromagnetic (EM) calorimeter. The CSA, designed in 0.35 $μ$m N-well CMOS technology using 5V MOS transistors, has a wide linear operating range of 2.6 pC w.r.t the input charge with a power dissipation of 2.3 mW. A noise figure (ENC) of 820 e$^-$ at 0 pF of detector capacitance with a noise slope of 25 e$^-$/pF has been achieved (when followed by a CR-RC$^2$ filter of 1.2 $μ$s peaking time). This design of CSA provides a dynamic range (ratio of maximum detectable signal to noise floor) of 79 dB for the maximum input charge of 2.6 pC when connected to a silicon detector with a capacitance of 40 pF. Using folded cascode architecture-based input stage and low voltage high swing current mirrors as the load, the CSA provides an enlarged output swing when biasing the output node towards one supply rail and utilizing the voltage range towards the opposite rail. The design philosophy works for both polarities of a large input signal. This paper presents the design of CSA with a wide negative output swing for an anticipated input signal of positive polarity in the target application with a known detector biasing scheme.

preprint2020arXiv

Fabrication and beam test of a silicon-tungsten electromagnetic calorimeter

A silicon-tungsten (Si-W) sampling calorimeter, consisting of 19 alternate layers of silicon pad detectors (individual pad area of 1~cm$^2$) and tungsten absorbers (each of one radiation length), has been constructed for measurement of electromagnetic showers over a large energy range. The signal from each of the silicon pads is readout using an ASIC with a dynamic range from $-300$~fC to $+500$~fC. Another ASIC with a larger dynamic range, $\pm 600$~fC has been used as a test study. The calorimeter was exposed to pion and electron beams at the CERN Super Proton Synchrotron (SPS) to characterise the response to minimum ionising particles (MIP) and showers from electromagnetic (EM) interactions. Pion beams of 120 GeV provided baseline measurements towards the understanding of the MIP behaviour in the silicon pad layers, while electron beams of energy from 5 GeV to 60 GeV rendered detailed shower profiles within the calorimeter. The energy deposition in each layer, the longitudinal shower profile, and the total energy deposition have been measured for each incident electron energy. Linear behaviour of the total measured energy ($E$) with that of the incident particle energy ($E_{0}$) ensured satisfactory calorimetric performance. For a subset of the data sample, selected based on the cluster position of the electromagnetic shower of the incident electron, the dependence of the measured energy resolution on $E_{0}$ has been found to be $σ/E = (15.36/\sqrt{E_0(\mathrm{GeV)}} \oplus 2.0) \%$.

preprint2020arXiv

Grover on SIMON

For any symmetric key cryptosystem with $n$-bit secret key, the key can be recovered in $O(2^{n/2})$ exploiting Grover search algorithm, resulting in the effective key length to be half. In this direction, subsequent work has been done on AES and some other block ciphers. On the other hand, lightweight ciphers like SIMON was left unexplored. In this backdrop, we present Grover's search algorithm on all the variants of SIMON and enumerate the quantum resources to implement such attack in terms of NOT, CNOT and Toffoli gates. We also provide the T-depth of the circuits and the number of qubits required for the attack. We show that the number of qubits required for implementing Grover on SIMON $2n/mn$ is $O(2nr+mn)$, where $r$ is the number of chosen plaintext-cipher text pairs. We run a reduced version of SIMON in IBMQ quantum simulator and the 14-qubits processor as well. We found that where simulation supports theory, the actual implementation is far from the reality due to the infidelity of the gates and short decoherence time of the qubits. The complete codes for all version of SIMON have also been presented.

preprint2013arXiv

Cryptanalysis of Wu and Xu's authentication scheme for Telecare Medicine Information Systems

Remote user authentication is desirable for a Telecare medicine information system (TMIS) to verify the correctness of remote users. In 2013, Jiang et al. proposed privacy preserving authentication scheme for TMIS. Recently, Wu and Xu analyzed Jiang's scheme and identify serious security flaws in their scheme, namely, user impersonation attack, DoS attack and off-line password guessing attack. In this article, we analyze Wu and Xu's scheme and show that their scheme is also vulnerable to off-line password guessing attack and does not protect user anonymity. Moreover, we identify the inefficiency of incorrect input detection of the login phase in Wu and Xu's scheme, where the smart card executes the login session in-spite of wrong input.