Source author record

Jogender Saini

Jogender Saini appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

5works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2022arXiv

A wide swing charge sensitive amplifier for a prototype Si-W EM calorimeter

A wide swing charge sensitive amplifier (CSA) has been developed, as a part of a front-end electronics (FEE) readout ASIC, for a prototype silicon tungsten (Si-W) based electromagnetic (EM) calorimeter. The CSA, designed in 0.35 $μ$m N-well CMOS technology using 5V MOS transistors, has a wide linear operating range of 2.6 pC w.r.t the input charge with a power dissipation of 2.3 mW. A noise figure (ENC) of 820 e$^-$ at 0 pF of detector capacitance with a noise slope of 25 e$^-$/pF has been achieved (when followed by a CR-RC$^2$ filter of 1.2 $μ$s peaking time). This design of CSA provides a dynamic range (ratio of maximum detectable signal to noise floor) of 79 dB for the maximum input charge of 2.6 pC when connected to a silicon detector with a capacitance of 40 pF. Using folded cascode architecture-based input stage and low voltage high swing current mirrors as the load, the CSA provides an enlarged output swing when biasing the output node towards one supply rail and utilizing the voltage range towards the opposite rail. The design philosophy works for both polarities of a large input signal. This paper presents the design of CSA with a wide negative output swing for an anticipated input signal of positive polarity in the target application with a known detector biasing scheme.

preprint2022arXiv

Performance of a prototype bakelite RPC at GIF++ using self-triggered electronics for the CBM Experiment at FAIR

The Muon Chamber (MuCh) is a sub-system of the Compressed Baryonic Matter (CBM) experiment for the detection of low-mass-vector mesons produced in high energy heavy-ion collisions at beam energies ranging from 2 AGeV to 11 AGeV and decaying in the di-muon channel. MuCh consists of a segmented absorber and four detector triplet stations sandwiched between the absorber segments. At the 3rd and 4th stations of MuCh, Resistive Plate Chambers (RPCs) have been conceived for muon tracking. We have tested the performance of a low resistivity bakelite RPC prototype equipped with self-triggered front end electronics (MuCh-XYTER) for the CBM Muon Chamber. A systematic study on the muon detection efficiency and time resolution has been carried out in a high-rate photon background at the Gamma Irradiation Facility (GIF++) at CERN. The details of the measurement setup and the results are presented here.

preprint2020arXiv

Fabrication and beam test of a silicon-tungsten electromagnetic calorimeter

A silicon-tungsten (Si-W) sampling calorimeter, consisting of 19 alternate layers of silicon pad detectors (individual pad area of 1~cm$^2$) and tungsten absorbers (each of one radiation length), has been constructed for measurement of electromagnetic showers over a large energy range. The signal from each of the silicon pads is readout using an ASIC with a dynamic range from $-300$~fC to $+500$~fC. Another ASIC with a larger dynamic range, $\pm 600$~fC has been used as a test study. The calorimeter was exposed to pion and electron beams at the CERN Super Proton Synchrotron (SPS) to characterise the response to minimum ionising particles (MIP) and showers from electromagnetic (EM) interactions. Pion beams of 120 GeV provided baseline measurements towards the understanding of the MIP behaviour in the silicon pad layers, while electron beams of energy from 5 GeV to 60 GeV rendered detailed shower profiles within the calorimeter. The energy deposition in each layer, the longitudinal shower profile, and the total energy deposition have been measured for each incident electron energy. Linear behaviour of the total measured energy ($E$) with that of the incident particle energy ($E_{0}$) ensured satisfactory calorimetric performance. For a subset of the data sample, selected based on the cluster position of the electromagnetic shower of the incident electron, the dependence of the measured energy resolution on $E_{0}$ has been found to be $σ/E = (15.36/\sqrt{E_0(\mathrm{GeV)}} \oplus 2.0) \%$.

preprint2015arXiv

High speed fault tolerant secure communication for muon chamber using fpga based gbt emulator

The Compressed Baryonic Matter (CBM) experiment is a part of the Facility for Antiproton and Ion Research (FAIR) in Darmstadt at the GSI. The CBM experiment will investigate the highly compressed nuclear matter using nucleus-nucleus collisions. This experiment will examine heavy-ion collisions in fixed target geometry and will be able to measure hadrons, electrons and muons. CBM requires precise time synchronization, compact hardware, radiation tolerance, self-triggered front-end electronics, efficient data aggregation schemes and capability to handle high data rate (up to several TB/s). As a part of the implementation of read out chain of MUCH in India, we have tried to implement FPGA based emulator of GBTx in India. GBTx is a radiation tolerant ASIC that can be used to implement multipurpose high speed bidirectional optical links for high-energy physics (HEP) experiments and is developed by CERN. GBTx will be used in highly irradiated area and more prone to be affected by multi bit error. To mitigate this effect instead of single bit error correcting RS code we have used two bit error correcting (15, 7) BCH code. It will increase the redundancy which in turn increases the reliability of the coded data. So the coded data will be less prone to be affected by noise due to radiation. Data will go from detector to PC through multiple nodes through the communication channel. In order to make the data communication secure, advanced encryption standard (AES - a symmetric key cryptography) and RSA (asymmetric key cryptography) are used after the channel coding.

preprint2014arXiv

Test and characterization of a prototype silicon-tungsten electromagnetic calorimeter

New generation high-energy physics experiments demand high precision tracking and accurate measurements of a large number of particles produced in the collisions of lementary particles and heavy-ions. Silicon-tungsten (Si-W) calorimeters provide the most viable technological option to meet the requirements of particle detection in high multiplicity environments. We report a novel Si-W calorimeter design, which is optimized for $γ/π^0$ discrimination up to high momenta. In order to test the feasibility of the calorimeter, a prototype mini-tower was constructed using silicon pad detector arrays and tungsten layers. The performance of the mini-tower was tested using pion and electron beams at the CERN Proton Synchrotron (PS). The experimental results are compared with the results from a detailed GEANT-4 simulation. A linear relationship between the observed energy deposition and simulated response of the mini-tower has been obtained, in line with our expectations.