Researcher profile

Simon Arridge

Simon Arridge contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
10works
0followers
16topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

10 published item(s)

preprint2022arXiv

Neural Network Kalman filtering for 3D object tracking from linear array ultrasound data

Many interventional surgical procedures rely on medical imaging to visualise and track instruments. Such imaging methods not only need to be real-time capable, but also provide accurate and robust positional information. In ultrasound applications, typically only two-dimensional data from a linear array are available, and as such obtaining accurate positional estimation in three dimensions is non-trivial. In this work, we first train a neural network, using realistic synthetic training data, to estimate the out-of-plane offset of an object with the associated axial aberration in the reconstructed ultrasound image. The obtained estimate is then combined with a Kalman filtering approach that utilises positioning estimates obtained in previous time-frames to improve localisation robustness and reduce the impact of measurement noise. The accuracy of the proposed method is evaluated using simulations, and its practical applicability is demonstrated on experimental data obtained using a novel optical ultrasound imaging setup. Accurate and robust positional information is provided in real-time. Axial and lateral coordinates for out-of-plane objects are estimated with a mean error of 0.1mm for simulated data and a mean error of 0.2mm for experimental data. Three-dimensional localisation is most accurate for elevational distances larger than 1mm, with a maximum distance of 6mm considered for a 25mm aperture.

preprint2022arXiv

Phase-insensitive versus phase-sensitive ultrasound absorption tomography in the frequency domain

The sensitivity of phase-sensitive detectors, such as piezoelectric detectors, becomes increasingly directional as the detector element size increases. In contrast, pyroelectric sensors, which are phase-insensitive, retain their omni-directionality even for large element sizes, although they have significantly poorer temporal resolution. This study uses numerical models to examine whether phase-insensitive detectors can be used advantageously in ultrasound tomography, specifically absorption tomography, when the number of detectors is sparse. We present measurement models for phase-sensitive and phase-insensitive sensors and compare the quality of the absorption reconstructions between these sensor types based on image contrast metrics. We perform the inversion using synthetic data with a Jacobian-based linearised matrix inversion approach.

preprint2020arXiv

Efficient inversion strategies for estimating optical properties with Monte Carlo radiative transport models

Indirect imaging problems in biomedical optics generally require repeated evaluation of forward models of radiative transport, for which Monte Carlo is accurate yet computationally costly. We develop a novel approach to reduce this bottleneck which has significant implications for quantitative tomographic imaging in a variety of medical and industrial applications. Using Monte Carlo we compute a fully stochastic gradient of an objective function for a given imaging problem. Leveraging techniques from the machine learning community we then adaptively control the accuracy of this gradient throughout the iterative inversion scheme, in order to substantially reduce computational resources at each step. For example problems of Quantitative Photoacoustic Tomography and Ultrasound Modulated Optical Tomography, we demonstrate that solutions are attainable using a total computational expense that is comparable to (or less than) that which is required for a single high accuracy forward run of the same Monte Carlo model. This approach demonstrates significant computational savings when approaching the full non-linear inverse problem of optical property estimation using stochastic methods.

preprint2020arXiv

Joint Reconstruction and Low-Rank Decomposition for Dynamic Inverse Problems

A primary interest in dynamic inverse problems is to identify the underlying temporal behaviour of the system from outside measurements. In this work we consider the case, where the target can be represented by a decomposition of spatial and temporal basis functions and hence can be efficiently represented by a low-rank decomposition. We then propose a joint reconstruction and low-rank decomposition method based on the Nonnegative Matrix Factorisation to obtain the unknown from highly undersampled dynamic measurement data. The proposed framework allows for flexible incorporation of separate regularisers for spatial and temporal features. For the special case of a stationary operator, we can effectively use the decomposition to reduce the computational complexity and obtain a substantial speed-up. The proposed methods are evaluated for two simulated phantoms and we compare the obtained results to a separate low-rank reconstruction and subsequent decomposition approach based on the widely used principal component analysis.

preprint2020arXiv

Multi-Scale Learned Iterative Reconstruction

Model-based learned iterative reconstruction methods have recently been shown to outperform classical reconstruction algorithms. Applicability of these methods to large scale inverse problems is however limited by the available memory for training and extensive training times, the latter due to computationally expensive forward models. As a possible solution to these restrictions we propose a multi-scale learned iterative reconstruction scheme that computes iterates on discretisations of increasing resolution. This procedure does not only reduce memory requirements, it also considerably speeds up reconstruction and training times, but most importantly is scalable to large scale inverse problems with non-trivial forward operators, such as those that arise in many 3D tomographic applications. In particular, we propose a hybrid network that combines the multi-scale iterative approach with a particularly expressive network architecture which in combination exhibits excellent scalability in 3D. Applicability of the algorithm is demonstrated for 3D cone beam computed tomography from real measurement data of an organic phantom. Additionally, we examine scalability and reconstruction quality in comparison to established learned reconstruction methods in two dimensions for low dose computed tomography on human phantoms.

preprint2020arXiv

Representation and reconstruction of covariance operators in linear inverse problems

We introduce a framework for the reconstruction and representation of functions in a setting where these objects cannot be directly observed, but only indirect and noisy measurements are available, namely an inverse problem setting. The proposed methodology can be applied either to the analysis of indirectly observed functional images or to the associated covariance operators, representing second-order information, and thus lying on a non-Euclidean space. To deal with the ill-posedness of the inverse problem, we exploit the spatial structure of the sample data by introducing a flexible regularizing term embedded in the model. Thanks to its efficiency, the proposed model is applied to MEG data, leading to a novel approach to the investigation of functional connectivity.

preprint2018arXiv

Approximate k-space models and Deep Learning for fast photoacoustic reconstruction

We present a framework for accelerated iterative reconstructions using a fast and approximate forward model that is based on k-space methods for photoacoustic tomography. The approximate model introduces aliasing artefacts in the gradient information for the iterative reconstruction, but these artefacts are highly structured and we can train a CNN that can use the approximate information to perform an iterative reconstruction. We show feasibility of the method for human in-vivo measurements in a limited-view geometry. The proposed method is able to produce superior results to total variation reconstructions with a speed-up of 32 times.

preprint2018arXiv

Enhancing Compressed Sensing 4D Photoacoustic Tomography by Simultaneous Motion Estimation

A crucial limitation of current high-resolution 3D photoacoustic tomography (PAT) devices that employ sequential scanning is their long acquisition time. In previous work, we demonstrated how to use compressed sensing techniques to improve upon this: images with good spatial resolution and contrast can be obtained from suitably sub-sampled PAT data acquired by novel acoustic scanning systems if sparsity-constrained image reconstruction techniques such as total variation regularization are used. Now, we show how a further increase of image quality can be achieved for imaging dynamic processes in living tissue (4D PAT). The key idea is to exploit the additional temporal redundancy of the data by coupling the previously used spatial image reconstruction models with sparsity-constrained motion estimation models. While simulated data from a two-dimensional numerical phantom will be used to illustrate the main properties of this recently developed joint-image-reconstruction-and-motion-estimation framework, measured data from a dynamic experimental phantom will also be used to demonstrate their potential for challenging, large-scale, real-world, three-dimensional scenarios. The latter only becomes feasible if a carefully designed combination of tailored optimization schemes is employed, which we describe and examine in more detail.

preprint2018arXiv

Model based learning for accelerated, limited-view 3D photoacoustic tomography

Recent advances in deep learning for tomographic reconstructions have shown great potential to create accurate and high quality images with a considerable speed-up. In this work we present a deep neural network that is specifically designed to provide high resolution 3D images from restricted photoacoustic measurements. The network is designed to represent an iterative scheme and incorporates gradient information of the data fit to compensate for limited view artefacts. Due to the high complexity of the photoacoustic forward operator, we separate training and computation of the gradient information. A suitable prior for the desired image structures is learned as part of the training. The resulting network is trained and tested on a set of segmented vessels from lung CT scans and then applied to in-vivo photoacoustic measurement data.

preprint2018arXiv

Real-time Cardiovascular MR with Spatio-temporal Artifact Suppression using Deep Learning - Proof of Concept in Congenital Heart Disease

PURPOSE: Real-time assessment of ventricular volumes requires high acceleration factors. Residual convolutional neural networks (CNN) have shown potential for removing artifacts caused by data undersampling. In this study we investigated the effect of different radial sampling patterns on the accuracy of a CNN. We also acquired actual real-time undersampled radial data in patients with congenital heart disease (CHD), and compare CNN reconstruction to Compressed Sensing (CS). METHODS: A 3D (2D plus time) CNN architecture was developed, and trained using 2276 gold-standard paired 3D data sets, with 14x radial undersampling. Four sampling schemes were tested, using 169 previously unseen 3D 'synthetic' test data sets. Actual real-time tiny Golden Angle (tGA) radial SSFP data was acquired in 10 new patients (122 3D data sets), and reconstructed using the 3D CNN as well as a CS algorithm; GRASP. RESULTS: Sampling pattern was shown to be important for image quality, and accurate visualisation of cardiac structures. For actual real-time data, overall reconstruction time with CNN (including creation of aliased images) was shown to be more than 5x faster than GRASP. Additionally, CNN image quality and accuracy of biventricular volumes was observed to be superior to GRASP for the same raw data. CONCLUSION: This paper has demonstrated the potential for the use of a 3D CNN for deep de-aliasing of real-time radial data, within the clinical setting. Clinical measures of ventricular volumes using real-time data with CNN reconstruction are not statistically significantly different from the gold-standard, cardiac gated, BH techniques.