Source author record

Si-Yuan Ma

Si-Yuan Ma appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2015arXiv

A Novel Method of Encoded Multiplexing Readout for Micro-pattern Gas Detectors

The requirement of a large number of electronic channels poses a big challenge for Micro-pattern Gas Detector (MPGD) to achieve good spatial resolution. By using the redundancy that at least two neighboring strips record the signal of a particle, a novel method of encoded multiplexing readout for MPGDs is presented in this paper. The method offers a feasible and easily-extensible way of encoding and decoding, and can significantly reduce the number of readout channels. A verification test was carried out on a 5*5 cm2 Thick Gas Electron Multiplier (THGEM) detector using a 8 keV Cu X-ray source with 100um slit, where 166 strips are read out by 21 encoded readout channels. The test results show a good linearity in its position response, and the spatial resolution root-mean-square (RMS) of the test system is about 260 μm. This method has an attractive potential to build large area detectors and can be easily adapted to other detectors like MPGDs.

preprint2015arXiv

Onboard Calibration Circuit for the Front-end Electronics of DAMPE BGO Calorimeter

An onboard calibration circuit has been designed for the front-end electronics (FEE) of DAMPE BGO Calorimeter. It is mainly composed of a 12 bit DAC, an operation amplifier and an analog switch. Test results showed that a dynamic range of 0 ~ 30 pC with a precision of 5 fC was achieved, which meets the requirements of the front-end electronics. Furthermore, it is used to test the trigger function of the FEEs. The calibration circuit has been implemented and verified by all the environmental tests for both Qualification Model and Flight Model of DAMPE. The DAMPE satellite will be launched at the end of 2015 and the calibration circuit will perform onboard calibration in space.