Researcher profile

Qi An

Qi An contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
10works
0followers
11topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

10 published item(s)

preprint2024arXiv

Multi-Stage Contrastive Regression for Action Quality Assessment

In recent years, there has been growing interest in the video-based action quality assessment (AQA). Most existing methods typically solve AQA problem by considering the entire video yet overlooking the inherent stage-level characteristics of actions. To address this issue, we design a novel Multi-stage Contrastive Regression (MCoRe) framework for the AQA task. This approach allows us to efficiently extract spatial-temporal information, while simultaneously reducing computational costs by segmenting the input video into multiple stages or procedures. Inspired by the graph contrastive learning, we propose a new stage-wise contrastive learning loss function to enhance performance. As a result, MCoRe demonstrates the state-of-the-art result so far on the widely-adopted fine-grained AQA dataset.

preprint2022arXiv

Convert widespread paraelectric perovskite to ferroelectrics

While nature provides a plethora of perovskite materials, only a few exhibits large ferroelectricity and possibly multiferroicity. The majority of perovskite materials have the non-polar CaTiO$_3$(CTO)structure, limiting the scope of their applications. Based on effective Hamiltonian model as well as first-principles calculations, we propose a general thin-film design method to stabilize the functional BiFeO$_3$(BFO)-type structure, which is a common metastable structure in widespread CaTiO$_3$-type perovskite oxides. It is found that the improper antiferroelectricity in CTO-type perovskite and ferroelectricity in BFO-type perovskite have distinct dependences on mechanical and electric boundary conditions, both of which involve oxygen octahedral rotation and tilt. The above difference can be used to stabilize the highly polar BFO-type structure in many CTO-type perovskite materials.

preprint2022arXiv

Enhancement of Healthcare Data Performance Metrics using Neural Network Machine Learning Algorithms

Patients are often encouraged to make use of wearable devices for remote collection and monitoring of health data. This adoption of wearables results in a significant increase in the volume of data collected and transmitted. The battery life of the devices is then quickly diminished due to the high processing requirements of the devices. Given the importance attached to medical data, it is imperative that all transmitted data adhere to strict integrity and availability requirements. Reducing the volume of healthcare data for network transmission may improve sensor battery life without compromising accuracy. There is a trade-off between efficiency and accuracy which can be controlled by adjusting the sampling and transmission rates. This paper demonstrates that machine learning can be used to analyse complex health data metrics such as the accuracy and efficiency of data transmission to overcome the trade-off problem. The study uses time series nonlinear autoregressive neural network algorithms to enhance both data metrics by taking fewer samples to transmit. The algorithms were tested with a standard heart rate dataset to compare their accuracy and efficiency. The result showed that the Levenbery-Marquardt algorithm was the best performer with an efficiency of 3.33 and accuracy of 79.17%, which is similar to other algorithms accuracy but demonstrates improved efficiency. This proves that machine learning can improve without sacrificing a metric over the other compared to the existing methods with high efficiency.

preprint2022arXiv

Mass Testing and Characterization of 20-inch PMTs for JUNO

Main goal of the JUNO experiment is to determine the neutrino mass ordering using a 20kt liquid-scintillator detector. Its key feature is an excellent energy resolution of at least 3 % at 1 MeV, for which its instruments need to meet a certain quality and thus have to be fully characterized. More than 20,000 20-inch PMTs have been received and assessed by JUNO after a detailed testing program which began in 2017 and elapsed for about four years. Based on this mass characterization and a set of specific requirements, a good quality of all accepted PMTs could be ascertained. This paper presents the performed testing procedure with the designed testing systems as well as the statistical characteristics of all 20-inch PMTs intended to be used in the JUNO experiment, covering more than fifteen performance parameters including the photocathode uniformity. This constitutes the largest sample of 20-inch PMTs ever produced and studied in detail to date, i.e. 15,000 of the newly developed 20-inch MCP-PMTs from Northern Night Vision Technology Co. (NNVT) and 5,000 of dynode PMTs from Hamamatsu Photonics K. K.(HPK).

preprint2021arXiv

Back-n White Neutron Source at CSNS and its Applications

Back-streaming neutrons from the spallation target of the China Spallation Neutron Source (CSNS) that emit through the incoming proton channel were exploited to build a white neutron beam facility (the so-called Back-n white neutron source), which was completed in March 2018. The Back-n neutron beam is very intense, at approximately 2*10^7 n/cm^2/s at 55 m from the target, and has a nominal proton beam with a power of 100 kW in the CSNS-I phase and a kinetic energy of 1.6 GeV and a thick tungsten target in multiple slices with modest moderation from the cooling water through the slices. In addition, the excellent energy spectrum spanning from 0.5 eV to 200 MeV, and a good time resolution related to the time-of-flight measurements make it a typical white neutron source for nuclear data measurements; its overall performance is among that of the best white neutron sources in the world. Equipped with advanced spectrometers, detectors, and application utilities, the Back-n facility can serve wide applications, with a focus on neutron-induced cross-section measurements. This article presents an overview of the neutron beam characteristics, the experimental setups, and the ongoing applications at Back-n.

preprint2021arXiv

JUNO Physics and Detector

The Jiangmen Underground Neutrino Observatory (JUNO) is a 20 kton LS detector at 700-m underground. An excellent energy resolution and a large fiducial volume offer exciting opportunities for addressing many important topics in neutrino and astro-particle physics. With 6 years of data, the neutrino mass ordering can be determined at 3-4 sigma and three oscillation parameters can be measured to a precision of 0.6% or better by detecting reactor antineutrinos. With 10 years of data, DSNB could be observed at 3-sigma; a lower limit of the proton lifetime of 8.34e33 years (90% C.L.) can be set by searching for p->nu_bar K^+; detection of solar neutrinos would shed new light on the solar metallicity problem and examine the vacuum-matter transition region. A core-collapse supernova at 10 kpc would lead to ~5000 IBD and ~2000 (300) all-flavor neutrino-proton (electron) scattering events. Geo-neutrinos can be detected with a rate of ~400 events/year. We also summarize the final design of the JUNO detector and the key R&D achievements. All 20-inch PMTs have been tested. The average photon detection efficiency is 28.9% for the 15,000 MCP PMTs and 28.1% for the 5,000 dynode PMTs, higher than the JUNO requirement of 27%. Together with the >20 m attenuation length of LS, we expect a yield of 1345 p.e. per MeV and an effective energy resolution of 3.02%/\sqrt{E (MeV)}$ in simulations. The underwater electronics is designed to have a loss rate <0.5% in 6 years. With degassing membranes and a micro-bubble system, the radon concentration in the 35-kton water pool could be lowered to <10 mBq/m^3. Acrylic panels of radiopurity <0.5 ppt U/Th are produced. The 20-kton LS will be purified onsite. Singles in the fiducial volume can be controlled to ~10 Hz. The JUNO experiment also features a double calorimeter system with 25,600 3-inch PMTs, a LS testing facility OSIRIS, and a near detector TAO.

preprint2020arXiv

Feasibility and physics potential of detecting $^8$B solar neutrinos at JUNO

The Jiangmen Underground Neutrino Observatory~(JUNO) features a 20~kt multi-purpose underground liquid scintillator sphere as its main detector. Some of JUNO&#39;s features make it an excellent experiment for $^8$B solar neutrino measurements, such as its low-energy threshold, its high energy resolution compared to water Cherenkov detectors, and its much large target mass compared to previous liquid scintillator detectors. In this paper we present a comprehensive assessment of JUNO&#39;s potential for detecting $^8$B solar neutrinos via the neutrino-electron elastic scattering process. A reduced 2~MeV threshold on the recoil electron energy is found to be achievable assuming the intrinsic radioactive background $^{238}$U and $^{232}$Th in the liquid scintillator can be controlled to 10$^{-17}$~g/g. With ten years of data taking, about 60,000 signal and 30,000 background events are expected. This large sample will enable an examination of the distortion of the recoil electron spectrum that is dominated by the neutrino flavor transformation in the dense solar matter, which will shed new light on the tension between the measured electron spectra and the predictions of the standard three-flavor neutrino oscillation framework. If $Δm^{2}_{21}=4.8\times10^{-5}~(7.5\times10^{-5})$~eV$^{2}$, JUNO can provide evidence of neutrino oscillation in the Earth at the about 3$σ$~(2$σ$) level by measuring the non-zero signal rate variation with respect to the solar zenith angle. Moveover, JUNO can simultaneously measure $Δm^2_{21}$ using $^8$B solar neutrinos to a precision of 20\% or better depending on the central value and to sub-percent precision using reactor antineutrinos. A comparison of these two measurements from the same detector will help elucidate the current tension between the value of $Δm^2_{21}$ reported by solar neutrino experiments and the KamLAND experiment.

preprint2020arXiv

Measurement of the neutron beam profile of the Back-n white neutron facility at CSNS with a Micromegas detector

The Back-n white neutron beam line, which uses back-streaming white neutrons from the spallation target of the China Spallation Neutron Source, is used for nuclear data measurements. A Micromegas-based neutron detector with two variants was specially developed to measure the beam spot distribution for this beam line. In this article, the design, fabrication, and characterization of the detector are described. The results of the detector performance tests are presented, which include the relative electron transparency, the gain and the gain uniformity, and the neutron beam profile reconstruction capability. The result of the first measurement of the Back-n neutron beam spot distribution is also presented.

preprint2020arXiv

TAO Conceptual Design Report: A Precision Measurement of the Reactor Antineutrino Spectrum with Sub-percent Energy Resolution

The Taishan Antineutrino Observatory (TAO, also known as JUNO-TAO) is a satellite experiment of the Jiangmen Underground Neutrino Observatory (JUNO). A ton-level liquid scintillator detector will be placed at about 30 m from a core of the Taishan Nuclear Power Plant. The reactor antineutrino spectrum will be measured with sub-percent energy resolution, to provide a reference spectrum for future reactor neutrino experiments, and to provide a benchmark measurement to test nuclear databases. A spherical acrylic vessel containing 2.8 ton gadolinium-doped liquid scintillator will be viewed by 10 m^2 Silicon Photomultipliers (SiPMs) of >50% photon detection efficiency with almost full coverage. The photoelectron yield is about 4500 per MeV, an order higher than any existing large-scale liquid scintillator detectors. The detector operates at -50 degree C to lower the dark noise of SiPMs to an acceptable level. The detector will measure about 2000 reactor antineutrinos per day, and is designed to be well shielded from cosmogenic backgrounds and ambient radioactivities to have about 10% background-to-signal ratio. The experiment is expected to start operation in 2022.

preprint2019arXiv

Measurements of differential and angle-integrated cross sections for the $^{10}$B($n, α$)$^{7}$Li reaction in the neutron energy range from 1.0 eV to 2.5 MeV

Differential and angle-integrated cross sections for the $^{10}$B($n, α$)$^{7}$Li, $^{10}$B($n, α$$_{0}$)$^{7}$Li and $^{10}$B($n, α$$_{1}$)$^{7}$Li$^{*}$ reactions have been measured at CSNS Back-n white neutron source. Two enriched (90%) $^{10}$B samples 5.0 cm in diameter and ~85.0 $μ$g/cm$^{2}$ in thickness each with an aluminum backing were prepared, and back-to-back mounted at the sample holder. The charged particles were detected using the silicon-detector array of the Light-charged Particle Detector Array (LPDA) system. The neutron energy E$_{n}$ was determined by TOF (time-of-flight) method, and the valid $α$ events were extracted from the E$_{n}$-Amplitude two-dimensional spectrum. With 15 silicon detectors, the differential cross sections of $α$-particles were measured from 19.2° to 160.8°. Fitted with the Legendre polynomial series, the ($n, α$) cross sections were obtained through integration. The absolute cross sections were normalized using the standard cross sections of the $^{10}$B($n, α$)$^{7}$Li reaction in the 0.3 - 0.5 MeV neutron energy region. The measurement neutron energy range for the $^{10}$B($n, α$)$^{7}$Li reaction is 1.0 eV $\le$ En < 2.5 MeV (67 energy points), and for the $^{10}$B($n, α$$_{0}$)$^{7}$Li and $^{10}$B($n, α$$_{1}$)$^{7}$Li$^{*}$ reactions is 1.0 eV $\le$ En < 1.0 MeV (59 energy points). The present results have been analyzed by the resonance reaction mechanism and the level structure of the $^{11}$B compound system, and compared with existing measurements and evaluations.