Researcher profile

Shunli Niu

Shunli Niu contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 13 - Baseline
2works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2015arXiv

p/${π^+}$ response of single layer THGEM detector in Ar/3%iC$_4$H$_{10}$

In this work, we study the response of single layer Thick GEM (THGEM) detector to p/${π^+}$ at E3 line of Beijing Test Beam Facility. In our experiment, the drift gap of THGEM Detector is 4mm, and the working gas is Ar/3% iso. Result shows at the momentum 500MeV/c to 1000MeV/c, detection efficiency for p is from 93% to 99% in a relatively lower gain($\sim$2000), while the detection efficiency for ${π^+}$ is slightly lower than that for p, which is from 82% to 88%. Meanwhile, simple Geant4 simulations have been done, and results of beam test are almost consistent with it. We preliminarily study the feasibility of THGEM detectors as sampling elements for Digital Hadronic Calorimeter(DHCAL), which may provide related reference for THGEM possibly applied in Circular Electron Positron Collider(CEPC) HCAL.

preprint2014arXiv

Simulation of background reduction and Compton depression in low-background HPGe spectrometer at a surface laboratory

High-purity germanium detectors are well suited to analysis the radioactivity of samples. In order to reduce the environmental background, low-activity lead and oxygen free copper are installed outside of the probe to shield gammas, outmost is a plastic scintillator to veto the cosmic rays, and an anti-Compton detector can improve the Peak-to-Compton ratio. Using the GEANT4 tools and taking into account a detailed description of the detector, we optimize the sizes of the detectors to reach the design indexes. A group of experimental data from a HPGe spectrometer in using were used to compare with the simulation. As to new HPGe Detector simulation, considering the different thickness of BGO crystals and anti-coincidence efficiency, the simulation results show that the optimal thickness is 5.5cm, and the Peak-to-Compton ratio of 40K is raised to 1000 when the anti-coincidence efficiency is 0.85. As the background simulation, 15 cm oxygen-free copper plus 10 cm lead can reduce the environmental gamma rays to 0.0024 cps/100 cm3 Ge (50keV~2.8MeV), which is about 10-5 of environmental background.