Source author record

Shiyong Wu

Shiyong Wu appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

8works
7topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

8 published item(s)

preprint2022arXiv

Study of background from accidental coincidence signals in the PandaX-II experiment

The PandaX-II experiment employed a 580kg liquid xenon detector to search for the interactions between dark matter particles and the target xenon atoms. The accidental coincidences of isolated signals result in a dangerous background which mimic the signature of the dark matter. We performed a detailed study on the accidental coincidence background in PandaX-II, including the possible origin of the isolated signals, the background level and corresponding background suppression method. With a boosted-decision-tree algorithm, the accidental coincidence background is reduced by 70% in the dark matter signal region, thus the sensitivity of dark matter search at PandaX-II is improved.

preprint2021arXiv

Internal Calibration of the PandaX-II Detector with Radon Gaseous Sources

We have developed a low-energy electron recoil (ER) calibration method with $^{220}$Rn for the PandaX-II detector. $^{220}$Rn, emanated from natural thorium compounds, was fed into the detector through the xenon purification system. From 2017 to 2019, we performed three dedicated calibration campaigns with different radon sources. We studied the detector response to $α$, $β$, and $γ$ particles with focus on low energy ER events. During the runs in 2017 and 2018, the amount of radioactivity of $^{222}$Rn were on the order of 1\% of that of $^{220}$Rn and thorium particulate contamination was negligible, especially in 2018. We also measured the background contribution from $^{214}$Pb for the first time in PandaX-II with the help from a $^{222}$Rn injection. Calibration strategy with $^{220}$Rn and $^{222}$Rn will be implemented in the upcoming PandaX-4T experiment and can be useful for other xenon-based detectors as well.

preprint2021arXiv

Results of Dark Matter Search using the Full PandaX-II Exposure

We report the dark matter search results obtained using the full 132 ton$\cdot$day exposure of the PandaX-II experiment, including all data from March 2016 to August 2018. No significant excess of events is identified above the expected background. Upper limits are set on the spin-independent dark matter-nucleon interactions. The lowest 90% confidence level exclusion on the spin-independent cross section is $2.2\times 10^{-46}$ cm$^2$ at a WIMP mass of 30 GeV/$c^2$.

preprint2019arXiv

Searching for Neutrino-less Double Beta Decay of $^{136}$Xe with PandaX-II Liquid Xenon Detector

We report the Neutrino-less Double Beta Decay (NLDBD) search results from PandaX-II dual-phase liquid xenon time projection chamber. The total live time used in this analysis is 403.1 days from June 2016 to August 2018. With NLDBD-optimized event selection criteria, we obtain a fiducial mass of 219 kg of natural xenon. The accumulated xenon exposure is 242 kg$\cdot$yr, or equivalently 22.2 kg$\cdot$yr of $^{136}$Xe exposure. At the region around $^{136}$Xe decay Q-value of 2458 keV, the energy resolution of PandaX-II is 4.2%. We find no evidence of NLDBD in PandaX-II and establish a lower limit for decay half-life of 2.4 $ \times 10^{23} $ yr at the 90% confidence level, which corresponds to an effective Majorana neutrino mass $m_{ββ} < (1.3 - 3.5)$ eV. This is the first NLDBD result reported from a dual-phase xenon experiment.

preprint2016arXiv

Dark Matter Results from First 98.7-day Data of PandaX-II Experiment

We report the WIMP dark matter search results using the first physics-run data of the PandaX-II 500 kg liquid xenon dual-phase time-projection chamber, operating at the China JinPing Underground Laboratory. No dark matter candidate is identified above background. In combination with the data set during the commissioning run, with a total exposure of 3.3$\times10^4$ kg-day,the most stringent limit to the spin-independent interaction between the ordinary and WIMP dark matter is set for a range of dark matter mass between 3.5 and 1000 GeV/c$^2$. The best upper limit on the scattering cross section is found $2.5\times 10^{-46}$ cm$^2$ for the WIMP mass 40 GeV/c$^2$ at 90% confidence level.

preprint2016arXiv

Dark Matter Search Results from the Commissioning Run of PandaX-II

We present the results of a search for WIMPs from the commissioning run of the PandaX-II experiment located at the China Jinping underground Laboratory. A WIMP search data set with an exposure of 306$\times$19.1 kg-day was taken, while its dominant $^{85}$Kr background was used as the electron recoil calibration. No WIMP candidates are identified, and a 90\% upper limit is set on the spin-independent elastic WIMP-nucleon cross section with a lowest excluded cross section of 2.97$\times$10$^{-45}$~cm$^2$ at a WIMP mass of 44.7~GeV/c$^2$.

preprint2015arXiv

Low-mass dark matter search results from full exposure of PandaX-I experiment

We report the results of a weakly-interacting massive particle (WIMP) dark matter search using the full 80.1\;live-day exposure of the first stage of the PandaX experiment (PandaX-I) located in the China Jin-Ping Underground Laboratory. The PandaX-I detector has been optimized for detecting low-mass WIMPs, achieving a photon detection efficiency of 9.6\%. With a fiducial liquid xenon target mass of 54.0\,kg, no significant excess event were found above the expected background. A profile likelihood analysis confirms our earlier finding that the PandaX-I data disfavor all positive low-mass WIMP signals reported in the literature under standard assumptions. A stringent bound on the low mass WIMP is set at WIMP mass below 10\,GeV/c$^2$, demonstrating that liquid xenon detectors can be competitive for low-mass WIMP searches.

preprint2014arXiv

First dark matter search results from the PandaX-I experiment

We report on the first dark-matter (DM) search results from PandaX-I, a low threshold dual-phase xenon experiment operating at the China Jinping Underground Laboratory. In the 37-kg liquid xenon target with 17.4 live-days of exposure, no DM particle candidate event was found. This result sets a stringent limit for low-mass DM particles and disfavors the interpretation of previously-reported positive experimental results. The minimum upper limit, $3.7\times10^{-44}$\,cm$^2$, for the spin-independent isoscalar DM-particle-nucleon scattering cross section is obtained at a DM-particle mass of 49\,GeV/c$^2$ at 90\% confidence level.