Source author record

Shao-Chun Zhang

Shao-Chun Zhang appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2021arXiv

A high-sensitivity fiber-coupled diamond magnetometer with surface coating

Nitrogen-vacancy quantum defects in diamond offer a promising platform for magnetometry because of their remarkable optical and spin properties. In this Letter, we present a high-sensitivity and wide-bandwidth fiber-based quantum magnetometer for practical applications. By coating the diamond surface with silver reflective film, both the fluorescence collection and excitation efficiency are enhanced. Additionally, tracking pulsed optically detected magnetic resonance spectrum allowed a magnetic field sensitivity of $35$ pT$/\sqrt{\rm{Hz}}$ and a bandwidth of $4.1$ KHz. Finally, this magnetometer was successfully applied to map the magnetic field induced by the current-carrying copper-wire mesh. Such a stable and compact magnetometry can provide a powerful tool in many areas of physical, chemical, and biological researches.

preprint2021arXiv

High resolution imaging with anomalous saturated excitation

The nonlinear fluorescence emission has been widely applied for the high spatial resolution optical imaging. Here, we studied the fluorescence anomalous saturating effect of the nitrogen vacancy defect in diamond. The fluorescence reduction was observed with high power laser excitation. It increased the nonlinearity of the fluorescence emission, and changed the spatial frequency distribution of the fluorescence image. We used a differential excitation protocol to extract the high spatial frequency information. By modulating the excitation laser's power, the spatial resolution of imaging was improved approximate 1.6 times in comparison with the confocal microscopy. Due to the simplicity of the experimental setup and data processing, we expect this method can be used for improving the spatial resolution of sensing and biological labeling with the defects in solids.