Researcher profile

Shany Biton

Shany Biton contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2022arXiv

ArNet-ECG: Deep Learning for the Detection of Atrial Fibrillation from the Raw Electrocardiogram

Atrial fibrillation (AF) is the most prevalent heart arrhythmia. AF manifests on the electrocardiogram (ECG) though irregular beat-to-beat time interval variation, the absence of P-wave and the presence of fibrillatory waves (f-wave). We hypothesize that a deep learning (DL) approach trained on the raw ECG will enable robust detection of AF events and the estimation of the AF burden (AFB). We further hypothesize that the performance reached leveraging the raw ECG will be superior to previously developed methods using the beat-to-beat interval variation time series. Consequently, we develop a new DL algorithm, denoted ArNet-ECG, to robustly detect AF events and estimate the AFB from the raw ECG and benchmark this algorithms against previous work. Methods: A dataset including 2,247 adult patients and totaling over 53,753 hours of continuous ECG from the University of Virginia (UVAF) was used. Results: ArNet-ECG obtained an F1 of 0.96 and ArNet2 obtained an F1 0.94. Discussion and conclusion: ArNet-ECG outperformed ArNet2 thus demonstrating that using the raw ECG provides added performance over the beat-to-beat interval time series. The main reason found for explaining the higher performance of ArNet-ECG was its high performance on atrial flutter examples versus poor performance on these recordings for ArNet2.

preprint2022arXiv

Estimation of f-wave Dominant Frequency Using a Voting Scheme

Introduction: Atrial fibrillation (AF) is the most common heart arrhythmia, characterized by the presence of fibrillatory waves (f-waves) in the ECG. We introduce a voting scheme to estimate the dominant atrial frequency (DAF) of f-waves. Methods: We analysed a subset of Holter recordings obtained from the University of Virginia AF Database. 100 Holter recordings with manually annotated AF events, resulting in a total 363 AF events lasting more than 1 min. The f-waves were extracted using four different template subtraction (TS) algorithms and the DAF was estimated from the first 1-min window of each AF event. A random forest classifier was used. We hypothesized that better extraction of the f-wave meant better AF/non-AF classification using the DAF as the single input feature of the RF model. Results: Performance on the test set, expressed in terms of AF/non-AF classification, was the best when the DAF was computed computed the three best-performing extraction methods. Using these three algorithms in a voting scheme, the classifier obtained AUC=0.60 and the DAFs were mostly spread around 6 Hz, 5.66 (4.83-7.47). Conclusions: This study has two novel contributions: (1) a method for assessing the performance of f-wave extraction algorithms, and (2) a voting scheme for improved DAF estimation.

preprint2022arXiv

Generalizable and Robust Deep Learning Algorithm for Atrial Fibrillation Diagnosis Across Ethnicities, Ages and Sexes

To drive health innovation that meets the needs of all and democratize healthcare, there is a need to assess the generalization performance of deep learning (DL) algorithms across various distribution shifts to ensure that these algorithms are robust. This retrospective study is, to the best of our knowledge, the first to develop and assess the generalization performance of a deep learning (DL) model for AF events detection from long term beat-to-beat intervals across ethnicities, ages and sexes. The new recurrent DL model, denoted ArNet2, was developed on a large retrospective dataset of 2,147 patients totaling 51,386 hours of continuous electrocardiogram (ECG). The models generalization was evaluated on manually annotated test sets from four centers (USA, Israel, Japan and China) totaling 402 patients. The model was further validated on a retrospective dataset of 1,730 consecutives Holter recordings from the Rambam Hospital Holter clinic, Haifa, Israel. The model outperformed benchmark state-of-the-art models and generalized well across ethnicities, ages and sexes. Performance was higher for female than male and young adults (less than 60 years old) and showed some differences across ethnicities. The main finding explaining these variations was an impairment in performance in groups with a higher prevalence of atrial flutter (AFL). Our findings on the relative performance of ArNet2 across groups may have clinical implications on the choice of the preferred AF examination method to use relative to the group of interest.

preprint2020arXiv

Remote atrial fibrillation burden estimation using deep recurrent neural network

The atrial fibrillation burden (AFB) is defined as the percentage of time spend in atrial fibrillation (AF) over a long enough monitoring period. Recent research has demonstrated the added prognosis value that becomes available by using the AFB as compared with the binary diagnosis. We evaluate, for the first time, the ability to estimate the AFB over long-term continuous recordings, using a deep recurrent neutral network (DRNN) approach. Methods: The models were developed and evaluated on a large database of p=2,891 patients, totaling t=68,800 hours of continuous electrocardiography (ECG) recordings acquired at the University of Virginia heart station. Specifically, 24h beat-to-beat time series were obtained from a single portable ECG channel. The network, denoted ArNet, was benchmarked against a gradient boosting (XGB) model, trained on 21 features including the coefficient of sample entropy (CosEn) and AFEvidence. Data were divided into training and test sets, while patients were stratified by the presence and severity of AF. The generalizations of ArNet and XGB were also evaluated on the independent test PhysioNet LTAF database. Results: the absolute AF burden estimation error |E_AF|, median and interquartile, on the test set, was 1.2 (0.1-6.7) for ArNet and 3.1 (0.0-11.7) for XGB for AF individuals. Generalization results on LTAF were consistent with E_AF of 2.6 (1.1-14.7) for ArNet and 3.6 (1.0-16.7) for XGB. Conclusion: This research demonstrates the feasibility of AFB estimation from 24h beat-to-beat interval time series utilizing recent advances in DRNN. Significance: The novel data-driven approach enables robust remote diagnosis and phenotyping of AF.