Researcher profile

Seung-Woo Hong

Seung-Woo Hong contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2024arXiv

Elastic p-12C scattering by using a cluster effective field theory

The elastic p-12C scattering at low energies is studied by using a cluster effective field theory (EFT), where the low-lying resonance states (s1/2, p3/2, d5/2) of 13N are treated as pertinent degrees of freedom. The low-energy constants of the Lagrangian are expressed in terms of the Coulomb-modified effective range parameters, which are determined to reproduce the experimental data for the differential cross-sections. The resulting theoretical predictions agree very well with the experimental data. The resulting theory is shown to give us almost identical phase shifts as obtained from the R-matrix approach. The role of the ground state of 13N below the threshold and the next-to-leading order in the EFT power counting are also discussed.

preprint2022arXiv

Semi-empirical model to determine pre- and post-neutron fission product yields and neutron multiplicity

Post-neutron emission fission product mass distributions are calculated by using pre-neutron emission fission product yields (FPYs) and neutron multiplicity. A semi-empirical model is used to calculate the pre-neutron FPY, first. Then the neutron multiplicity for each fission fragment mass is used to convert the pre-neutron FPY to the post-neutron FPY. In doing so, assumptions are made for the probability for a pre-emission fission fragment with a mass number $A^*$ to decay to a post-emission fragment with a mass number $A$. The resulting post-neutron FPYs are compared with the data available. The systems where the experimental data of not only the pre- and post-neutron FPY but also neutron multiplicity are available are the thermal neutron-induced fission of $^{233}$U, $^{235}$U and $^{239}$Pu. Thus, we applied the model calculations to these systems and compared the calculation results with those from the GEF and the data from the ENDF and the EXFOR libraries. Both the pre- and post-neutron fission product mass distributions calculated by using the semi-empirical model and the neutron multiplicity reproduce the overall features of the experimental data.

preprint2020arXiv

Effects of transient non-thermal particles on the big bang nucleosynthesis

The effects of introducing a small amount of non-thermal distribution (NTD) of elements in big bang nucleosynthesis (BBN) are studied by allowing a fraction of the NTD to be time-dependent so that it contributes only during a certain period of the BBN evolution. The fraction is modeled as a Gaussian-shaped function of $\log(T)$, where $T$ is the temperature of the cosmos, and thus the function is specified by three parameters; the central temporal position, the width and the magnitude. The change in the average nuclear reaction rates due to the presence of the NTD is assumed to be proportional to the Maxwellian reaction rates but with temperature $T_{\rm NTD} \equiv ζT$, $ζ$ being another parameter of our model. By scanning a wide four-dimensional parametric space at about half a million points, we have found about 130 points with $χ^2< 1$, at which the predicted primordial abundances of light elements are consistent with the observations. The magnitude parameter $\varepsilon_0$ of these points turns out to be scattered over a very wide range from $\varepsilon_0 \sim 10^{-19}$ to $\sim 10^{-1}$, and the $ζ$-parameter is found to be strongly correlated with the magnitude parameter $\varepsilon_0$. The temperature region with $0.3\times 10^9 \mbox{K} \lesssim T \lesssim 0.4\times 10^9 \mbox{K}$ or the temporal region $t\simeq 10^3$ s seems to play a central role in lowering $χ^2$.

preprint2013arXiv

Percentage depth dose distributions in inhomogeneous phantoms with lung and bone equivalent media for small fields of CyberKnife

The percentage depth dose distributions in inhomogeneous phantoms with lung and bone equivalent media are studied. For lung equivalent media a Balsa wood is used, and for a soft bone equivalent media a compound material with epoxy resin, hardener and calcium carbonate is used. Polystyrene slabs put together with these materials are used as an inhomogeneous phantom. Dose measurements are performed with Gafchromic EBT film by using photon beams from 6MV CyberKnife at the Seoul Uridul Hospital. The cone sizes of the photon beams are varied from 5, 10 to 30 mm. As a simulation tool GEANT4 Monte Carlo code v9.4.p02 is used. When the Balsa wood is inserted in the phantom, the dose measured with EBT film is found to be significantly different from the dose without the EBT film in and beyond the Balsa wood region, particularly for small field sizes. On the other hand, when the soft bone equivalent material is inserted in the phantom, discrepancy between the dose measured with EBT film and the dose without EBT film can be seen only in the region of bone equivalent material. GEANT4 simulations are done with and without the EBT film to compare the simulation results with measurements. We find that the simulations including EBT film agree with the measurements for all the cases within an error of $2.2\%$. Also, we find the &#34;doses to phantom&#34; without the EBT film differ from the &#34;doses to film&#34; up to $29\%$, which shows that for accurate dose estimations for inhomogeneous phantoms with EBT film the presence of the EBT film needs to be taken into account properly in particular for small fields.