Source author record

Kyung Joo Min

Kyung Joo Min appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
5topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2020arXiv

Effects of transient non-thermal particles on the big bang nucleosynthesis

The effects of introducing a small amount of non-thermal distribution (NTD) of elements in big bang nucleosynthesis (BBN) are studied by allowing a fraction of the NTD to be time-dependent so that it contributes only during a certain period of the BBN evolution. The fraction is modeled as a Gaussian-shaped function of $\log(T)$, where $T$ is the temperature of the cosmos, and thus the function is specified by three parameters; the central temporal position, the width and the magnitude. The change in the average nuclear reaction rates due to the presence of the NTD is assumed to be proportional to the Maxwellian reaction rates but with temperature $T_{\rm NTD} \equiv ζT$, $ζ$ being another parameter of our model. By scanning a wide four-dimensional parametric space at about half a million points, we have found about 130 points with $χ^2< 1$, at which the predicted primordial abundances of light elements are consistent with the observations. The magnitude parameter $\varepsilon_0$ of these points turns out to be scattered over a very wide range from $\varepsilon_0 \sim 10^{-19}$ to $\sim 10^{-1}$, and the $ζ$-parameter is found to be strongly correlated with the magnitude parameter $\varepsilon_0$. The temperature region with $0.3\times 10^9 \mbox{K} \lesssim T \lesssim 0.4\times 10^9 \mbox{K}$ or the temporal region $t\simeq 10^3$ s seems to play a central role in lowering $χ^2$.

preprint2015arXiv

Yield estimation of neutron-rich rare isotopes induced by 200 MeV/u $^{132}$Sn beams by using GEANT4

A so-called "two-step reaction scheme", in which neutron-rich rare isotopes obtained from ISOL are post-accelerated and bombarded on a second target, is employed to estimate the production yields of exotic rare isotopes. The production yields of neutron-rich rare isotope fragments induced by 200 MeV/u $^{132}$Sn beams bombarded on a $^{9}$Be target are estimated with Monte Carlo code, GEANT4. To substantiate the use of GEANT4 for this study, benchmark calculations are done for 80 MeV/u $^{59}$Co, 95 MeV/u $^{72}$Zn, 500 MeV/u $^{92}$Mo, and 950 MeV/u $^{132}$Sn beams on the $^{9}$Be target. It is found that $^{132}$Sn beams can produce neutron-rich rare isotopes with 45 $\leq$ Z $\leq$ 50 more effectively than $^{238}$U beams at the same energy per nucleon.

preprint2013arXiv

Percentage depth dose distributions in inhomogeneous phantoms with lung and bone equivalent media for small fields of CyberKnife

The percentage depth dose distributions in inhomogeneous phantoms with lung and bone equivalent media are studied. For lung equivalent media a Balsa wood is used, and for a soft bone equivalent media a compound material with epoxy resin, hardener and calcium carbonate is used. Polystyrene slabs put together with these materials are used as an inhomogeneous phantom. Dose measurements are performed with Gafchromic EBT film by using photon beams from 6MV CyberKnife at the Seoul Uridul Hospital. The cone sizes of the photon beams are varied from 5, 10 to 30 mm. As a simulation tool GEANT4 Monte Carlo code v9.4.p02 is used. When the Balsa wood is inserted in the phantom, the dose measured with EBT film is found to be significantly different from the dose without the EBT film in and beyond the Balsa wood region, particularly for small field sizes. On the other hand, when the soft bone equivalent material is inserted in the phantom, discrepancy between the dose measured with EBT film and the dose without EBT film can be seen only in the region of bone equivalent material. GEANT4 simulations are done with and without the EBT film to compare the simulation results with measurements. We find that the simulations including EBT film agree with the measurements for all the cases within an error of $2.2\%$. Also, we find the "doses to phantom" without the EBT film differ from the "doses to film" up to $29\%$, which shows that for accurate dose estimations for inhomogeneous phantoms with EBT film the presence of the EBT film needs to be taken into account properly in particular for small fields.