Source author record

Seung-hyun Kim

Seung-hyun Kim appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2015arXiv

Thermoelectric Signal Enhancement by Reconciling the Spin Seebeck and Anomalous Nernst Effects in Ferromagnet/Non-magnet Multilayers

The utilization of ferromagnetic (FM) materials in thermoelectric devices allows one to have a simpler structure and/or independent control of electric and thermal conductivities, which may further remove obstacles for this technology to be realized. The thermoelectricity in FM/non-magnet (NM) heterostructures using an optical heating source is studied as a function of NM materials and a number of multilayers. It is observed that the overall thermoelectric signal in those structures which is contributed by spin Seebeck effect and anomalous Nernst effect (ANE) is enhanced by a proper selection of NM materials with a spin Hall angle that matches to the sign of the ANE. Moreover, by an increase of the number of multilayer, the thermoelectric voltage is enlarged further and the device resistance is reduced, simultaneously. The experimental observation of the improvement of thermoelectric properties may pave the way for the realization of magnetic-(or spin-) based thermoelectric devices.

preprint2013arXiv

Exploring anti-reflection modes in disordered media

Sensing and manipulating targets hidden under scattering media are universal problems that take place in applications ranging from deep-tissue optical imaging to laser surgery. A major issue in these applications is the shallow light penetration caused by multiple scattering that reflects most of incident light. Although advances have been made to eliminate image distortion by a scattering medium, dealing with the light reflection has remained unchallenged. Here we present a method to minimize reflected intensity by finding and coupling light into the anti-reflection modes of a scattering medium. In doing so, we achieved more than a factor of 3 increase in light penetration. Our method of controlling reflected waves makes it readily applicable to in vivo applications in which detector sensors can only be positioned at the same side of illumination and will therefore lay the foundation of advancing the working depth of many existing optical imaging and treatment technologies.