Source author record

Sergio Fantini

Sergio Fantini appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

3works
5topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2023arXiv

Dual-slope imaging of cerebral hemodynamics with frequency-domain near-infrared spectroscopy

Significance: This work targets the contamination of optical signals by superficial hemodynamics, which is one of the chief hurdles in non-invasive optical measurements of the human brain. Aim: To identify optimal source-detector distances for Dual-Slope (DS) measurements in Frequency-Domain (FD) Near-InfraRed Spectroscopy (NIRS) and demonstrate preferential sensitivity of Dual-Slope (DS) imaging to deeper tissue (brain) versus superficial tissue (scalp). Approach: Theoretical studies (in-silico) based on diffusion theory in two-layered and in homogeneous scattering media. In-vivo demonstrations of DS imaging of the human brain during visual stimulation and during systemic blood pressure oscillations. Results: The mean distance (between the two source-detector distances needed for DS) is the key factor for depth sensitivity. In-vivo imaging of the human occipital lobe with FD NIRS and a mean distance of 31 mm indicated: (1) greater hemodynamic response to visual stimulation from FD phase versus intensity, and from DS versus Single-Distance (SD); (2) hemodynamics from FD phase and DS mainly driven by blood flow, and hemodynamics from SD intensity mainly driven by blood volume. Conclusions: DS imaging with FD NIRS may suppress confounding contributions from superficial hemodynamics without relying on data at short source-detector distances. This capability can have significant implications for non-invasive optical measurements of the human brain.

preprint2022arXiv

Method for Measuring Absolute Optical Properties of Turbid Samples in a Standard Cuvette

Many applications seek to measure a sample's absorption coefficient spectrum to retrieve the chemical makeup. Many real world samples are optically turbid, causing scattering confounds which many commercial spectrometers cannot address. Using diffusion theory and considering absorption and reduced scattering coefficients on the order of 0.01 per mm and 1 per mm, respectively, we develop a method which utilizes frequency-domain to measure absolute optical properties of turbid samples in a standard cuvette (45 mm by 10 mm by 10 mm). Inspired by the self calibrating method, which removes instrumental confounds, the method uses measurements of the diffuse complex transmittance at two sets of two different source-detector distances. We find: this works best for highly scattering samples (reduced scattering coefficient above 1 per mm); higher relative error in the absorption coefficient compared to the reduced scattering coefficient; accuracy is tied to knowledge of the samples index of refraction. Noise simulations with 0.1 percent amplitude and 0.1 deg (1.7 mrad) phase uncertainty find errors in absorption and reduced scattering coefficients of 4 percent and 1 percent, respectively. We expect that higher error in the absorption coefficient can be alleviated with highly scattering samples and that boundary condition confounds may be suppressed by designing a cuvette with high index of refraction. Further work will investigate implementation and reproducibility.

preprint2014arXiv

Fast algorithms for hyperspectral Diffuse Optical Tomography

The image reconstruction of chromophore concentrations using Diffuse Optical Tomography (DOT) data can be described mathematically as an ill-posed inverse problem. Recent work has shown that the use of hyperspectral DOT data, as opposed to data sets comprising of a single or, at most, a dozen wavelengths, has the potential for improving the quality of the reconstructions. The use of hyperspectral diffuse optical data in the formulation and solution of the inverse problem poses a significant computational burden. The forward operator is, in actuality, nonlinear. However, under certain assumptions, a linear approximation, called the Born approximation, provides a suitable surrogate for the forward operator, and we assume this to be true in the present work. Computation of the Born matrix requires the solution of thousands of large scale discrete PDEs and the reconstruction problem, requires matrix-vector products with the (dense) Born matrix. In this paper, we address both of these difficulties, thus making the Born approach a computational viable approach for hyDOT reconstruction. In this paper, we assume that the images we wish to reconstruct are anomalies of unknown shape and constant value, described using a parametric level set approach, (PaLS) on a constant background. Specifically, to address the issue of the PDE solves, we develop a novel recycling-based Krylov subspace approach that leverages certain system similarities across wavelengths. To address expense of using the Born operator in the inversion, we present a fast algorithm for compressing the Born operator that locally compresses across wavelengths for a given source-detector set and then recursively combines the low-rank factors to provide a global low-rank approximation. This low-rank approximation can be used implicitly to speed up the recovery of the shape parameters and the chromophore concentrations.