Source author record

Sergey V. Pereverzev

Sergey V. Pereverzev appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

2works
2topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

2 published item(s)

preprint2022arXiv

Thermodynamic Stability of Xenon-Doped Liquid Argon Detectors

Liquid argon detectors are employed in a wide variety of nuclear and particle physics experiments. The addition of small quantities of xenon to argon modifies its scintillation, ionization, and electroluminescence properties and can improve its performance as a detection medium. However, a liquid argon-xenon mixture can develop instabilities, especially in systems that require phase transitions or that utilize high xenon concentrations. In this work, we discuss the causes for such instabilities and describe a small (liter-scale) apparatus with a unique cryogenic circuit specifically designed to handle argon-xenon mixtures. The system is capable of condensing argon gas mixed with O(1%) xenon by volume and maintains a stable liquid mixture near the xenon saturation limit while actively circulating it in the gas phase. We also demonstrate control over instabilities that develop when the detector condition is allowed to deviate from optimized settings. This progress enables future liquid argon detectors to benefit from the effects of high concentrations of xenon doping, such as more efficient detection of low-energy ionization signals. This work also develops tools to study and mitigate instabilities in large argon detectors that use low concentration xenon doping.

preprint2012arXiv

Energy-resolved detection of single infrared photons with λ = 8 μm using a superconducting microbolometer

We report on the detection of single photons with λ = 8 μm using a superconducting hot-electron microbolometer. The sensing element is a titanium transition-edge sensor with a volume ~ 0.1 μm^3 fabricated on a silicon substrate. Poisson photon counting statistics including simultaneous detection of 3 photons was observed. The width of the photon-number peaks was 0.11 eV, 70% of the photon energy, at 50-100 mK. This achieved energy resolution is one of the best figures reported so far for superconducting devices. Such devices can be suitable for single photon calorimetric spectroscopy throughout the mid-infrared and even the far-infrared.