Researcher profile

Boris S. Karasik

Boris S. Karasik contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
8works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

8 published item(s)

preprint2014arXiv

Monolayer graphene bolometer as a sensitive far-IR detector

In this paper we give a detailed analysis of the expected sensitivity and operating conditions in the power detection mode of a hot-electron bolometer (HEB) made from a few μm$^2$ of monolayer graphene (MLG) flake which can be embedded into either a planar antenna or waveguide circuit via NbN (or NbTiN) superconducting contacts with critical temperature ~ 14 K. Recent data on the strength of the electron-phonon coupling are used in the present analysis and the contribution of the readout noise to the Noise Equivalent Power (NEP) is explicitly computed. The readout scheme utilizes Johnson Noise Thermometry (JNT) allowing for Frequency-Domain Multiplexing (FDM) using narrowband filter coupling of the HEBs. In general, the filter bandwidth and the summing amplifier noise have a significant effect on the overall system sensitivity. The analysis shows that the readout contribution can be reduced to that of the bolometer phonon noise if the detector device is operated at 0.05 K and the JNT signal is read at about 10 GHz where the Johnson noise emitted in equilibrium is substantially reduced. Beside the high sensitivity (NEP < 10$^{-20}$ W/Hz$^{1/2}$, this bolometer does not have any hard saturation limit and thus can be used for far-IR sky imaging with arbitrary contrast. By changing the operating temperature of the bolometer the sensitivity can be fine tuned to accommodate the background photon flux in a particular application. By using a broadband low-noise kinetic inductance parametric amplifier, ~100s of graphene HEBs can be read simultaneously without saturation of the system output.

preprint2014arXiv

Normal Metal Hot-Electron Nanobolometer with Johnson Noise Thermometry Readout

The sensitivity of a THz hot-electron nanobolometer (nano-HEB) made from a normal metal is analyzed. Johnson Noise Thermometry (JNT) is employed as a readout technique. In contrast to its superconducting TES counterpart, the normal-metal nano-HEB can operate at any cryogenic temperature depending on the required radiation background limited Noise Equivalent Power (NEP). It does not require bias lines; 100s of nano-HEBs can be read by a single low-noise X-band amplifier via a filter bank channelizer. The modeling predicts that even with the sensitivity penalty due to the amplifier noise, an NEP ~ 10$^{-20}$ - 10$^{-19}$ W/Hz$^{1/2}$ can be expected at 50-100 mK in 10-20 nm thin titanium (Ti) normal metal HEBs with niobium (Nb) contacts. This NEP is fairly constant over a range of readout frequencies ~ 10 GHz. Although materials with weaker electron-phonon coupling (bismuth, graphene) do not improve the minimum achievable NEP, they can be considered if a larger than 10 GHz readout bandwidth is required.

preprint2014arXiv

Prospective performance of graphene HEB for ultrasensitive detection of sub-mm radiation

Noise Equivalent Power and time constant of a submillimeter wave Hot-Electron Bolometer (HEB) made from monolayer graphene are analyzed using the lowest electron-phonon thermal conductance data reported to date. Frequency-domain multiplexed Johnson Noise Thermometry (JNT) is used for the detector readout. Planar microantennas or waveguides can provide efficient coupling of the graphene microdevice to radiation. The results show that the graphene HEB detector can be radiation background limited at very low level corresponding to the photon noise on a space telescope with cryogenically cooled mirror. Beside the high sensitivity, absence of a hard power saturation limit, higher operating temperature, and the ability to read 1000s of elements with a single broadband amplifier will be the advantages of such a detector.

preprint2013arXiv

Graphene microbolometers with superconducting contacts for terahertz photon detection

We report on noise and thermal conductance measurements taken in order to determine an upper bound on the performance of graphene as a terahertz photon detector. The main mechanism for sensitive terahertz detection in graphene is bolometric heating of the electron system. To study the properties of a device using this mechanism to detect terahertz photons, we perform Johnson noise thermometry measurements on graphene samples. These measurements probe the electron-phonon behavior of graphene on silicon dioxide at low temperatures. Because the electron-phonon coupling is weak in graphene, superconducting contacts with large gap are used to confine the hot electrons and prevent their out-diffusion. We use niobium nitride leads with a $T_\mathrm{c}\approx 10$ K to contact the graphene. We find these leads make good ohmic contact with very low contact resistance. Our measurements find an electron-phonon thermal conductance that depends quadratically on temperature above 4 K and is compatible with single terahertz photon detection.

preprint2012arXiv

Energy-resolved detection of single infrared photons with λ = 8 μm using a superconducting microbolometer

We report on the detection of single photons with λ = 8 μm using a superconducting hot-electron microbolometer. The sensing element is a titanium transition-edge sensor with a volume ~ 0.1 μm^3 fabricated on a silicon substrate. Poisson photon counting statistics including simultaneous detection of 3 photons was observed. The width of the photon-number peaks was 0.11 eV, 70% of the photon energy, at 50-100 mK. This achieved energy resolution is one of the best figures reported so far for superconducting devices. Such devices can be suitable for single photon calorimetric spectroscopy throughout the mid-infrared and even the far-infrared.

preprint2012arXiv

Nanobolometers for THz Photon Detection

This article reviews the state of rapidly emerging terahertz hot-electron nanobolometers (nano-HEB), which are currently among of the most sensitive radiation power detectors at submillimeter wavelengths. With the achieved noise equivalent power close to 10^{-19} W/Hz^{1/2} and potentially capable of approaching NEP ~ 10^{-20} W/Hz^{1/2}, nano-HEBs are very important for future space astrophysics platforms with ultralow submillimeter radiation background. The ability of these sensors to detect single low-energy photons opens interesting possibilities for quantum calorimetry in the mid-infrared and even in the farinfrared parts of the electromagnetic spectrum. We discuss the competition in the field of ultrasensitive detectors, the physics and technology of nano-HEBs, recent experimental results, and perspectives for future development.

preprint2012arXiv

Performance of Graphene Thermal Photon Detectors

We analyze the performance of graphene microstructures as thermal photon detectors and deduce the range of parameters that define a linear response. The saturation effects of a graphene thermal detector that operates beyond the linear range are described in detail for a single-photon detector (calorimeter). We compute the effect of operating beyond this linear range and find that sensitive detection occurs for such non-linear operation. We identify the optimum conditions and find that single-photon detection at terahertz (THz) frequencies should be feasible.

preprint2010arXiv

Optical NEP in Hot-Electron Nanobolometers

For the first time, we have measured the optical noise equivalent power (NEP) in titanium (Ti) superconducting hot-electron nanobolometers (nano-HEBs). The bolometers were 2μmx1μmx20nm and 1μmx1μmx20nm planar antenna-coupled devices. The measurements were done at λ = 460 μm using a cryogenic black body radiation source delivering optical power from a fraction of a femtowatt to a few 100s of femtowatts. A record low NEP = 3x10^{-19} W/Hz^{1/2} at 50 mK has been achieved. This sensitivity meets the requirements for SAFARI instrument on the SPICA telescope. The ways for further improvement of the nano-HEB detector sensitivity are discussed.