Researcher profile

Sergey P. Vyatchanin

Sergey P. Vyatchanin contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
13works
0followers
5topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

13 published item(s)

preprint2022arXiv

Combination of dissipative and dispersive coupling in the cavity optomechanical systems

An analysis is given for the Fabry-Perot cavity having a combination of dissipative and dispersive optomechanical coupling. It is established that the combined coupling leads to optical rigidity. At the same time, this rigidity appears in systems with the combined coupling on the resonant pump, which is not typical for pure dispersive and dissipative couplings. A proposal is made to use this system to detect small signal forces with better sensitivity than SQL. It is also demonstrated that this optomechanical system can create ponderomotive squeezing with controllable parameters over a wider range than ponderomotive squeezing using dispersive coupling.

preprint2020arXiv

Dissipative coupling, dispersive coupling and its combination in simplest opto-mechanical systems

We apply strategy of variational measurement to simplest variant of dissipative coupling (test mass displacement change transitivity of a single mirror) and compare it with simplest dispersive coupling (a single mirror as a test mass, which position changes the phase of reflected wave). We compare a ponderomotive squeezing in this two kinds of coupling. Also we analyze simplest variant of combined coupling, in which both dissipative and dispersive couplings are used, and show that it creates stable optical rigidity even in case of single pump. We demonstrate that variational measurement can be applied for combined coupling.

preprint2020arXiv

Polarization loss in reflecting coating

In laser gravitational waves detectors optical loss restricts sensitivity. We discuss polarization scattering as one more possible mechanism of optical losses. Circulated inside interferometer light is polarized and after reflection its plane of polarization can turn a little due to reflecting coating of mirror can have slightly different refraction index along axes $x,\, y$ in plane of mirror surface (optical anisotropy). This anisotropy can be produced during manufacture of coating (elasto-optic effect). This orthogonal polarized light, enhanced in cavity, produces polarization optical loss. Polarization map of mirrors is very important and we propose to measure it. Polarization loss can be important in different precision optical experiments based on usage of polarized light, for example, in quantum speed meter.

preprint2015arXiv

Optical Gravitational Wave Antenna with Increased Power Handling Capability

Fundamental sensitivity of an optical interferometric gravitational wave detector increases with increase of the optical power which, in turn, limited because of the opto-mechanical parametric instabilities of the interferometer. We propose to optimize geometrical shape of the mirrors of the detector to reduce the diffraction-limited finesse of unessential optical modes of the interferometer resulting in increase of the threshold of the opto-mechanical instabilities and subsequent increase of the measurement sensitivity. Utilizing parameters of the LIGO interferometer we found that the proposed technique allows constructing a Fabry-Perot interferometer with round trip diffraction loss of the fundamental mode not exceeding $5$~ppm, whereas the loss of the first dipole as well as the other high order modes exceed $1,000$~ppm and $8,000$~ppm, respectively. The optimization comes at the price of tighter tolerances on the mirror tilt stability, but does not result in a significant modification of the optical beam profile and does not require changes in the the gravity detector read-out system. The cavity with proposed mirrors is also stable with respect to the slight modification of the mirror shape.

preprint2014arXiv

On limitation of quality factor of single mode resonators with finite size

Using realistic numerical models we analyze radiative loss of bound and unbound modes of specially designed high-Q whispering gallery and Fabry-Perot cavities of similar size and shape, and find a set of parameters when they can be treated as single mode structures. We show that these cavities have similar properties in spite of their different loss mechanisms. The cavity morphology engineering does not lead to reduction of the resonator quality factor.

preprint2014arXiv

Time evolution of parametric instability in large-scale gravitational-wave interferometers

We present a study of three-mode parametric instability in large-scale gravitational-wave detectors. Previous work used a linearised model to study the onset of instability. This paper presents a non-linear study of this phenomenon, which shows that the initial stage of exponential rise of the amplitudes of a higher order optical mode and the mechanical internal mode of the mirror is followed by a saturation phase, in which all three participating modes reach a new equilibrium state with constant oscillation amplitudes. Results suggest that stable operation of interferometers may be possible in the presence of such instabilities, thereby simplifying the task of suppression.

preprint2013arXiv

Back action cancellation in resolved sideband regime

We consider the simple model of measurement of mechanical oscillator position via Fabry-Pero cavity pumped by detuned laser (end mirror of cavity is mass of oscillator) in resolved sideband regime when laser is detuned from cavity's frequency by frequency of mechanical oscillator $\pmω_m$ and relaxation rate $γ$ of cavity is small: $γ\ll ω_m$. We demonstrate fluctuation back action cancellation in reflected wave. However, it does not allow to circumvent Standard Quantum Limit, the reason of it is the dynamic back action.

preprint2013arXiv

Calculation of thermal noise in grating reflectors

Grating reflectors have been repeatedly discussed to improve the noise performance of metrological applications due to the reduction or absence of any coating material. So far, however, no quantitative estimate on the thermal noise of these reflective structures exists. In this work we present a theoretical calculation of a grating reflector's noise. We further apply it to a proposed 3rd generation gravitational wave detector. Depending on the grating geometry, the grating material and the temperature we obtain a thermal noise decrease by up to a factor of ten compared to conventional dielectric mirrors. Thus the use of grating reflectors can substantially improve the noise performance in metrological applications.

preprint2013arXiv

Observation of Three-Mode Parametric Instability

Three-mode parametric interactions can occur in triply-resonant opto-mechanical systems in which two orthogonal optical modes are coupled with an appropriate mechanical mode. Using an optical cavity with a membrane inside, we report the first observation of three-mode parametric instability in a Fabry-Perot cavity, a phenomenon predicted to occur in long baseline advanced gravitational wave detectors. We present a large signal model for the phenomenon, which predicts exponential growth of mechanical oscillation followed by saturation. Our experimental results are consistent with this model. Contrary to expectations, parametric instability does not lead to loss of cavity lock, a fact which may make it easier to implement control techniques in Advanced gravitational wave detectors.

preprint2013arXiv

Squeezing of optomechanical modes in detuned Fabry-Perot interferometer

We carry out analysis of optomechanical system formed by moveable mirror of Fabry-Perot cavity pumped by detuned laser. Optical spring arising from detuned pump creates in the system several eigen modes which could be treated as high-Q oscillators. Modulation of laser power results in parametric modulation of oscillators spring constants thus allowing to squeeze noise in quadratures of the modes. Evidence of the squeezing could be found in the light reflected from the cavity.

preprint2012arXiv

Sensitivity of laser gravitational-wave detectors with stable double-pumped optical spring

We analyze the sensitivity of gravitational-wave antenna with stable double optical spring created by two independent pumps. We investigate regime of three close eigen frequencies (roots of characteristic equation) which appears to provide more wide frequency band in which sensitivity of antenna can beat Standard Quantum Limit (SQL) than previously considered regime with two close eigen frequencies. We take into account optical losses and show that they do not degrade sensitivity significantly. We also demonstrate possible application of considered regime to Einstein Telescope.

preprint2011arXiv

Reducing Thermal Noise in Future Gravitational Wave Detectors by employing Khalili Etalons

Reduction of thermal noise in dielectric mirror coatings is a key issue for the sensitivity improvement in second and third generation interferometric gravitational wave detectors. Replacing an end mirror of the interferometer by an anti-resonant cavity (a so-called Khalili cavity) has been proposed to realize the reduction of the overall thermal noise level. In this article we show that the use of a Khalili etalon, which requires less hardware than a Khalili cavity, yields still a significant reduction of thermal noise. We identify the optimum distribution of coating layers on the front and rear surfaces of the etalon and compare the total noise budget with a conventional mirror. In addition we briefly discuss advantages and disadvantages of the Khalili etalon compared with the Khalili cavity in terms of technical aspects, such as interferometric length control and thermal lensing.

preprint2011arXiv

Reduction of coating thermal noise by using an etalon

Reduction of coating thermal noise is a key issue in precise measurements with an optical interferometer. A good example of such a measurement device is a gravitational-wave detector, where each mirror is coated by a few tens of quarter-wavelength dielectric layers to achieve high reflectivity while the thermal-noise level increases with the number of layers. One way to realize the reduction of coating thermal noise, recently proposed by Khalili, is the mechanical separation of the first few layers from the rest so that a major part of the fluctuations contributes only little to the phase shift of the reflected light. Using an etalon, a Fabry-Perot optical resonator of a monolithic cavity, with a few coating layers on the front and significantly more on the back surface is a way to realize such a system without too much complexity, and in this paper we perform a thermal-noise analysis of an etalon using the Fluctuation-dissipation theorem with probes on both sides of a finite-size cylindrical mirror.