Researcher profile

Sebastian Kozerke

Sebastian Kozerke contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 17 - UnverifiedVerification L1Unclaimed author
4works
0followers
6topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2022arXiv

MRXCAT-CDTI: A Numerical Cardiac Diffusion Tensor Imaging Phantom

Magnetic Resonance cardiac diffusion tensor imaging (cDTI) and cardiac intravoxel incoherent motion imaging enables probing of in vivo myofiber architecture and myocardial perfusion surrogates. To study the impact of experimental parameters such as resolution, off-resonances and heart-rate variations, we propose a numerical open-source framework called MRXCAT-CDTI. It allows simulating diffusion and perfusion contrast for spin-echo (SE) and stimulated echo acquisition mode (STEAM) cDTI sequences. The Fourier encoder supports in-plane and/or through-slice off-resonance effects, as well as T2* effects during single-shot image encoding. Optional lesions are included to mimic ischemic and infarcted myocardial regions. MRXCAT-CDTI allows assessing realistic influences on data acquisition, and how these affect the data encoding process and subsequent data processing. As an example, heart-rate variations lead to differences in partial saturation and relaxation of magnetization that end up in errors of 9 to 30% for cDTI angle metrics if not accounted for. For SE echo-planar cDTI, in-plane off-resonance effects more adversely affect cDTI metrics compared to through-slice off-resonances. With this work we propose an open-source MRXCAT-CDTI numerical simulation framework that offers realistic image encoding effects found in cardiac diffusion and perfusion data to systematically study influences of data encoding, reconstruction, and post-processing to promote reproducible research.

preprint2020arXiv

Deep variational network for rapid 4D flow MRI reconstruction

Phase-contrast magnetic resonance imaging (MRI) provides time-resolved quantification of blood flow dynamics that can aid clinical diagnosis. Long in vivo scan times due to repeated three-dimensional (3D) volume sampling over cardiac phases and breathing cycles necessitate accelerated imaging techniques that leverage data correlations. Standard compressed sensing reconstruction methods require tuning of hyperparameters and are computationally expensive, which diminishes the potential reduction of examination times. We propose an efficient model-based deep neural reconstruction network and evaluate its performance on clinical aortic flow data. The network is shown to reconstruct undersampled 4D flow MRI data in under a minute on standard consumer hardware. Remarkably, the relatively low amounts of tunable parameters allowed the network to be trained on images from 11 reference scans while generalizing well to retrospective and prospective undersampled data for various acceleration factors and anatomies.

preprint2020arXiv

Improved Segmentation and Detection Sensitivity of Diffusion-Weighted Brain Infarct Lesions with Synthetically Enhanced Deep Learning

Purpose: To compare the segmentation and detection performance of a deep learning model trained on a database of human-labelled clinical diffusion-weighted (DW) stroke lesions to a model trained on the same database enhanced with synthetic DW stroke lesions. Methods: In this institutional review board approved study, a stroke database of 962 cases (mean age 65+/-17 years, 255 males, 449 scans with DW positive stroke lesions) and a normal database of 2,027 patients (mean age 38+/-24 years,1088 females) were obtained. Brain volumes with synthetic DW stroke lesions were produced by warping the relative signal increase of real strokes to normal brain volumes. A generic 3D U-Net was trained on four different databases to generate four different models: (a) 375 neuroradiologist-labeled clinical DW positive stroke cases(CDB);(b) 2,000 synthetic cases(S2DB);(c) CDB+2,000 synthetic cases(CS2DB); or (d) CDB+40,000 synthetic cases(CS40DB). The models were tested on 20%(n=192) of the cases of the stroke database, which were excluded from the training set. Segmentation accuracy was characterized using Dice score and lesion volume of the stroke segmentation, and statistical significance was tested using a paired, two-tailed, Student&#39;s t-test. Detection sensitivity and specificity was compared to three neuroradiologists. Results: The performance of the 3D U-Net model trained on the CS40DB(mean Dice 0.72) was better than models trained on the CS2DB (0.70,P <0.001) or the CDB(0.65,P<0.001). The deep learning model was also more sensitive (91%[89%-93%]) than each of the three human readers(84%[81%-87%],78%[75%-81%],and 79%[76%-82%]), but less specific(75%[72%-78%] vs for the three human readers (96%[94%-97%],92%[90%-94%] and 89%[86%-91%]). Conclusion: Deep learning training for segmentation and detection of DW stroke lesions was significantly improved by enhancing the training set with synthetic lesions.

preprint2020arXiv

Simulation of Intravoxel Incoherent Perfusion Signal Using a Realistic Capillary Network of a Mouse Brain

Purpose: To simulate the intravoxel incoherent perfusion magnetic resonance magnitude signal from the motion of blood particles in three realistic vascular network graphs from a mouse brain. Methods: In three networks generated from the cortex of a mouse scanned by two-photon laser microscopy, blood flow in each vessel was simulated using Poiseuille law. The trajectories, flow speeds and phases acquired by a fixed number of simulated blood particles during a Stejskal-Tanner monopolar pulse gradient scheme were computed. The resulting magnitude signal as a function of b-value was obtained by integrating all phases and the pseudo-diffusion coefficient D* was estimated by fitting an exponential signal decay. To better understand the anatomical source of the IVIM perfusion signal, the above was repeated by restricting the simulation to various types of vessels. Results: The characteristics of the three microvascular networks were respectively: vessel lengths [mean +/- std. dev.]: 67.2 +/- 53.6 um, 59.8 +/- 46.2 um, and 64.5 +/- 50.9 um; diameters: 6.0 +/- 3.5 um, network 2: 5.7 +/- 3.6 um, and network 3: 6.1 +/- 3.7 um; simulated blood velocity: 0.9 +/- 1.7 um/ms, 1.4 +/- 2.5 um/ms and 0.7 +/- 2.1 um/ms. Exponential fitting of the simulated signal decay as a function of b-value resulted in the following D* [10-3 mm2/s]: 31.7, 40.4 and 33.4. The signal decay for low b-values was the largest in the larger vessels, but the smaller vessels and the capillaries accounted more to the total volume of the networks. Conclusion:This simulation improves the theoretical understanding of the IVIM perfusion estimation method by directly linking the MR IVIM perfusion signal to an ultra-high resolution measurement of the microvascular network and a realistic blood flow simulation.