Researcher profile

Georg Spinner

Georg Spinner contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 11 - UnverifiedVerification L1Unclaimed author
1works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

1 published item(s)

preprint2020arXiv

Simulation of Intravoxel Incoherent Perfusion Signal Using a Realistic Capillary Network of a Mouse Brain

Purpose: To simulate the intravoxel incoherent perfusion magnetic resonance magnitude signal from the motion of blood particles in three realistic vascular network graphs from a mouse brain. Methods: In three networks generated from the cortex of a mouse scanned by two-photon laser microscopy, blood flow in each vessel was simulated using Poiseuille law. The trajectories, flow speeds and phases acquired by a fixed number of simulated blood particles during a Stejskal-Tanner monopolar pulse gradient scheme were computed. The resulting magnitude signal as a function of b-value was obtained by integrating all phases and the pseudo-diffusion coefficient D* was estimated by fitting an exponential signal decay. To better understand the anatomical source of the IVIM perfusion signal, the above was repeated by restricting the simulation to various types of vessels. Results: The characteristics of the three microvascular networks were respectively: vessel lengths [mean +/- std. dev.]: 67.2 +/- 53.6 um, 59.8 +/- 46.2 um, and 64.5 +/- 50.9 um; diameters: 6.0 +/- 3.5 um, network 2: 5.7 +/- 3.6 um, and network 3: 6.1 +/- 3.7 um; simulated blood velocity: 0.9 +/- 1.7 um/ms, 1.4 +/- 2.5 um/ms and 0.7 +/- 2.1 um/ms. Exponential fitting of the simulated signal decay as a function of b-value resulted in the following D* [10-3 mm2/s]: 31.7, 40.4 and 33.4. The signal decay for low b-values was the largest in the larger vessels, but the smaller vessels and the capillaries accounted more to the total volume of the networks. Conclusion:This simulation improves the theoretical understanding of the IVIM perfusion estimation method by directly linking the MR IVIM perfusion signal to an ultra-high resolution measurement of the microvascular network and a realistic blood flow simulation.