Source author record

S. Schonert

S. Schonert appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

8works
7topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

8 published item(s)

preprint2022arXiv

Search for Low-Energy Signals from Fast Radio Bursts with the Borexino Detector

The search for neutrino events in correlation with several of the most intense fast radio bursts (FRBs) has been performed using the Borexino data. We have searched for signals with visible energies above $250$~keV within a time window of $\pm$1000~s corresponding to the detection time of a particular FRB. We also applied an alternative approach based on searching for specific shapes of neutrino-electron scattering spectra in the full exposure spectrum of the Borexino detector. In particular, two incoming neutrino spectra were considered: the monoenergetic line and the spectrum expected from supernovae. The same spectra were considered for electron antineutrinos detected through the inverse beta-decay reaction. No statistically significant excess over the background was observed. As a result, the strongest upper limits on FRB-associated neutrino fluences of all flavors have been obtained in the $0.5 - 50$~MeV neutrino energy range.

preprint2018arXiv

Speeding up complex multivariate data analysis in Borexino with parallel computing based on Graphics Processing Unit

A spectral fitter based on the graphics processor unit (GPU) has been developed for Borexino solar neutrino analysis. It is able to shorten the fitting time to a superior level compared to the CPU fitting procedure. In Borexino solar neutrino spectral analysis, fitting usually requires around one hour to converge since it includes time-consuming convolutions in order to account for the detector response and pile-up effects. Moreover, the convergence time increases to more than two days when including extra computations for the discrimination of $^{11}$C and external $γ$s. In sharp contrast, with the GPU-based fitter it takes less than 10 seconds and less than four minutes, respectively. This fitter is developed utilizing the GooFit project with customized likelihoods, pdfs and infrastructures supporting certain analysis methods. In this proceeding the design of the package, developed features and the comparison with the original CPU fitter are presented.

preprint2016arXiv

Cryogenic silicon detectors with implanted contacts for the detection of visible photons using the Neganov-Luke Effect

There is a common need in astroparticle experiments such as direct dark matter detection, 0ν\b{eta}\b{eta} (double beta decay without emission of neutrinos) and Coherent Neutrino Nucleus Scattering experiments for light detectors with a very low energy threshold. By employing the Neganov-Luke Effect, the thermal signal of particle interactions in a semiconductor absorber operated at cryogenic temperatures, can be amplified by drifting the photogenerated electrons and holes in an electric field. This technology is not used in current experiments, in particular because of a reduction of the signal amplitude with time which is due to trapping of the charges within the absorber. We present here the first results of a novel type of Neganov-Luke Effect detector with an electric field configuration designed to improve the charge collection within the semiconductor.

preprint2014arXiv

Ortho-positronium observation in the Double Chooz Experiment

The Double Chooz experiment measures the neutrino mixing angle $θ_{13}$ by detecting reactor $\barν_e$ via inverse beta decay. The positron-neutron space and time coincidence allows for a sizable background rejection, nonetheless liquid scintillator detectors would profit from a positron/electron discrimination, if feasible in large detector, to suppress the remaining background. Standard particle identification, based on particle dependent time profile of photon emission in liquid scintillator, can not be used given the identical mass of the two particles. However, the positron annihilation is sometimes delayed by the ortho-positronium (o-Ps) metastable state formation, which induces a pulse shape distortion that could be used for positron identification. In this paper we report on the first observation of positronium formation in a large liquid scintillator detector based on pulse shape analysis of single events. The o-Ps formation fraction and its lifetime were measured, finding the values of 44$\%$ $\pm$ 12$\%$ (sys.) $\pm$ 5$\%$ (stat.) and $3.68$ns $\pm$ 0.17ns (sys.) $\pm$ 0.15ns (stat.) respectively, in agreement with the results obtained with a dedicated positron annihilation lifetime spectroscopy setup.

preprint2013arXiv

New limits on heavy sterile neutrino mixing in ${^{8}\rm{B}}$-decay obtained with the Borexino detector

If heavy neutrinos with mass $m_{ν_{H}}\geq$2$ m_e $ are produced in the Sun via the decay ${^8\rm{B}} \rightarrow {^8\rm{Be}} + e^+ + ν_H$ in a side branch of pp-chain, they would undergo the observable decay into an electron, a positron and a light neutrino $ν_{H}\rightarrowν_{L}+e^++e^-$. In the present work Borexino data are used to set a bound on the existence of such decays. We constrain the mixing of a heavy neutrino with mass 1.5 MeV $\leq m_{ν_{H}} \le$ 14 MeV to be $|U_{eH}|^2\leq (10^{-3}-4\times10^{-6})$ respectively. These are tighter limits on the mixing parameters than obtained in previous experiments at nuclear reactors and accelerators.

preprint2012arXiv

Borexino calibrations: Hardware, Methods, and Results

Borexino was the first experiment to detect solar neutrinos in real-time in the sub-MeV region. In order to achieve high precision in the determination of neutrino rates, the detector design includes an internal and an external calibration system. This paper describes both calibration systems and the calibration campaigns that were carried out in the period between 2008 and 2011. We discuss some of the results and show that the calibration procedures preserved the radiopurity of the scintillator. The calibrations provided a detailed understanding of the detector response and led to a significant reduction of the systematic uncertainties in the Borexino measurements.

preprint2012arXiv

Reactor electron antineutrino disappearance in the Double Chooz experiment

The Double Chooz experiment has observed 8,249 candidate electron antineutrino events in 227.93 live days with 33.71 GW-ton-years (reactor power x detector mass x livetime) exposure using a 10.3 cubic meter fiducial volume detector located at 1050 m from the reactor cores of the Chooz nuclear power plant in France. The expectation in case of theta13 = 0 is 8,937 events. The deficit is interpreted as evidence of electron antineutrino disappearance. From a rate plus spectral shape analysis we find sin^2 2θ13 = 0.109 \pm 0.030(stat) \pm 0.025(syst). The data exclude the no-oscillation hypothesis at 99.8% CL (2.9σ).