Source author record

S. Schiller

S. Schiller appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

12works
9topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

12 published item(s)

preprint2022arXiv

Solution of the two-center Dirac equation with 20 digits precision using the finite-element technique

We present a precise fully relativistic numerical solution of the two-center Coulomb problem. The special case of unit nuclear charges is relevant for the accurate description of the ${\rm H}_2^+$ molecular ion and its isotopologues, systems that are an active experimental topic. The computation utilizes the 2-spinor minmax approach and the finite-element method. The computed total energies have estimated fractional uncertainties of a few times $10^{-20}$ for unit charges and a bond length of 2 atomic units. The fractional uncertainty of the purely relativistic contribution is $1\times10^{-17}$. The result is relevant for future precision experiments, whereas at present the uncertainties arising from the quantum electrodynamic treatment of the rovibrational transition frequencies. are dominant.

preprint2021arXiv

Search for oscillations of fundamental constants using molecular spectroscopy

A possible implication of an ultralight dark matter (UDM) field interacting wibeginth the Standard Model (SM) degrees of freedom is oscillations of fundamental constants. Here, we establish direct experimental bounds on the coupling of an oscillating UDM field to the up, down, and strange quarks and to the gluons, for oscillation frequencies between 10 Hz and 10^8 Hz. We employ spectroscopic experiments that take advantage of the dependence of molecular transition frequencies on the nuclear masses. Our results apply to previously unexplored frequency bands, and improve on existing bounds at frequencies > 5 MHz. We identify a sector of UDM - SM coupling space where the bounds from Equivalence Principle tests may be challenged by next-generation experiments of the present kind.

preprint2020arXiv

Hyperfine structure and electric quadrupole transitions in the deuterium molecular ion

Molecular hydrogen ions are of metrological relevance due to the possibility of precise theoretical evaluation of their spectrum and of external-field-induced shifts. In homonuclear molecular ions the electric dipole $E1$ transitions are strongly suppressed, and of primary laser spectroscopy interest is the electric quadrupole ($E2$) transition spectrum. In continuation of previous work on the H$_2^+$ ion, we report here the results of the calculations of the hyperfine structure of the laser-induced electric quadrupole transitions between a large set of ro-vibrational states of D$_2^+$; the inaccuracies of previous evaluations have been corrected. The effects of the laser polarization are studied in detail. We show that the electric quadrupole moment of the deuteron can in principle be determined with low fractional uncertainty $(\simeq1\times10^{-4})$ by comparing the results presented here with future data from precision spectroscopy of D$_2^+$.

preprint2020arXiv

Time keeping and searching for new physics using metastable states of Cu, Ag and Au

We study the prospects of using the electric quadrupole transitions from the ground states of Cu, Ag and Au to the metastable state $^2{\rm D}_{5/2}$ as clock transitions in optical lattice clocks. We calculate lifetimes, transition rates, systematic shifts, and demonstrate that the fractional uncertainty of the clocks can be similar to what is achieved in the best current optical clocks. The use of these proposed clocks for the search of new physics, such as time variation of the fine structure constant, search for low-mass scalar dark matter, violation of Local Position Invariance and violation of Lorenz Invariance is discussed.

preprint2016arXiv

Development of a strontium optical lattice clock for the SOC mission on the ISS

The ESA mission "Space Optical Clock" project aims at operating an optical lattice clock on the ISS in approximately 2023. The scientific goals of the mission are to perform tests of fundamental physics, to enable space-assisted relativistic geodesy and to intercompare optical clocks on the ground using microwave and optical links. The performance goal of the space clock is less than $1 \times 10^{-17}$ uncertainty and $1 \times 10^{-15} τ^{-1/2}$ instability. Within an EU-FP7-funded project, a strontium optical lattice clock demonstrator has been developed. Goal performances are instability below $1 \times 10^{-15} τ^{-1/2}$ and fractional inaccuracy $5 \times 10^{-17}$. For the design of the clock, techniques and approaches suitable for later space application are used, such as modular design, diode lasers, low power consumption subunits, and compact dimensions. The Sr clock apparatus is fully operational, and the clock transition in $^{88}$Sr was observed with linewidth as small as 9 Hz.

preprint2015arXiv

Development of a strontium optical lattice clock for the SOC mission on the ISS

Ultra-precise optical clocks in space will allow new studies in fundamental physics and astronomy. Within an European Space Agency (ESA) program, the Space Optical Clocks (SOC) project aims to install and to operate an optical lattice clock on the International Space Station (ISS) towards the end of this decade. It would be a natural follow-on to the ACES mission, improving its performance by at least one order of magnitude. The payload is planned to include an optical lattice clock, as well as a frequency comb, a microwave link, and an optical link for comparisons of the ISS clock with ground clocks located in several countries and continents. Within the EU-FP7-SPACE-2010-1 project no. 263500, during the years 2011-2015 a compact, modular and robust strontium lattice optical clock demonstrator has been developed. Goal performance is a fractional frequency instability below 1x10^{-15}, tau^{-1/2} and a fractional inaccuracy below 5x10^{-17}. Here we describe the current status of the apparatus' development, including the laser subsystems. Robust preparation of cold {88}^Sr atoms in a second stage magneto-optical trap (MOT) is achieved.

preprint2012arXiv

Addressing and manipulation of individual hyperfine states in cold trapped molecular ions and application to HD^{+} frequency metrology

Advanced techniques for manipulation of internal states, standard in atomic physics, are demonstrated for a charged molecular species for the first time. We address individual hyperfine states of ro-vibrational levels of a diatomic ion by optical excitation of individual hyperfine transitions, and achieve controlled transfer of population into a selected hyperfine state. We use molecular hydrogen ions (HD^{+}) as a model system and employ a novel frequency-comb-based, continuous-wave 5 \mum laser spectrometer. The achieved spectral resolution is the highest obtained so far in the optical domain on a molecular ion species. As a consequence, we are also able to perform the most precise test yet of the ab-initio theory of a molecule.

preprint2012arXiv

Observation of a rotational transition in trapped and sympathetically cooled molecular ions

We demonstrate rotational excitation of molecular ions that are sympathetically cooled by laser-cooled atomic ions to a temperature as low as ca. 10 mK. The molecular hydrogen ions HD+ and the fundamental rotational transition $(v=0,\, N=0)\rightarrow(v'=0,\, N'=1)$ at 1.3 THz, the most fundamental dipole-allowed rotational transition of any molecule, are used as a test case. This transition is here observed for the first time directly. Rotational laser cooling was employed in order to increase the signal, and resonance-enhanced multiphoton dissociation was used as detection method. The black-body-radiation-induced rotational excitation is also observed. The extension of the method to other molecular species is briefly discussed.

preprint2012arXiv

The Space Optical Clocks Project: Development of high-performance transportable and breadboard optical clocks and advanced subsystems

The use of ultra-precise optical clocks in space ("master clocks") will allow for a range of new applications in the fields of fundamental physics (tests of Einstein's theory of General Relativity, time and frequency metrology by means of the comparison of distant terrestrial clocks), geophysics (mapping of the gravitational potential of Earth), and astronomy (providing local oscillators for radio ranging and interferometry in space). Within the ELIPS-3 program of ESA, the "Space Optical Clocks" (SOC) project aims to install and to operate an optical lattice clock on the ISS towards the end of this decade, as a natural follow-on to the ACES mission, improving its performance by at least one order of magnitude. The payload is planned to include an optical lattice clock, as well as a frequency comb, a microwave link, and an optical link for comparisons of the ISS clock with ground clocks located in several countries and continents. Undertaking a necessary step towards optical clocks in space, the EU-FP7-SPACE-2010-1 project no. 263500 (SOC2) (2011-2015) aims at two "engineering confidence", accurate transportable lattice optical clock demonstrators having relative frequency instability below 1\times10^-15 at 1 s integration time and relative inaccuracy below 5\times10^-17. This goal performance is about 2 and 1 orders better in instability and inaccuracy, respectively, than today's best transportable clocks. The devices will be based on trapped neutral ytterbium and strontium atoms. One device will be a breadboard. The two systems will be validated in laboratory environments and their performance will be established by comparison with laboratory optical clocks and primary frequency standards. In this paper we present the project and the results achieved during the first year.

preprint2005arXiv

An experiment to detect gravity at sub-mm scale with high-Q mechanical oscillators

Silicon double paddle oscillators are well suited for the detection of weak forces because of their high Q factor (about 10^5 at room temperature). We describe an experiment aimed at the detection of gravitational forces between masses at sub-mm distance using such an oscillator. Gravitational excitation is produced by a rotating aluminium disk with platinum segments. The force sensitivity of this apparatus is about 10 fN at room temperature for 1000 s averaging time at room temperature. The current limitations to detection of the gravitational force are mentioned.

preprint2004arXiv

Sympathetic cooling of $^4$He$^+$ ions in a radiofrequency trap

We have generated Coulomb crystals of ultracold $^4$He$^+$ ions in a linear radiofrequency trap, by sympathetic cooling via laser--cooled $^9$Be$^+$. Stable crystals containing up to 150 localized He$^+$ ions at $\sim$20 mK were obtained. Ensembles or single ultracold He$^+$ ions open up interesting perspectives for performing precision tests of QED and measurements of nuclear radii. The present work also indicates the feasibility of cooling and crystallizing highly charged atomic ions using $^9$Be$^+$ as coolant.