Researcher profile

S. Osterman

S. Osterman contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 15 - Baseline
3works
0followers
3topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

3 published item(s)

preprint2010arXiv

A 12.5 GHz-Spaced Optical Frequency Comb Spanning >400 nm for near-Infrared Astronomical Spectrograph Calibration

A 12.5 GHz-spaced optical frequency comb locked to a Global Positioning disciplined oscillator for near-IR spectrograph calibration is presented. The comb is generated via filtering a 250 MHz-spaced comb. Subsequency nonlinear broadening of the 12.5 GHz comb extends the wavelength range to cover 1380 nm to 1820 nm, providing complete coverage over the H-band transmission widow of Earth's atmosphere. Finite suppression of spurious sidemodes, optical linewidth and instability of the comb have been examined to estmiate potential wavelength biases in spectrograph calibration. Sidemode suppression varies between 20 db and 45 dB, and the optical linewidth is ~350 kHz at 1550 nm. The comb frequency uncertainty is bounded by +/- 30 kHz (corresponding to a radial velocity of +/- 5 cm/s), limited by the Global Positioning System disciplined oscillator reference. These results indicate this comb can readily support radial velocity measurements below 1 m/s in the near-IR.

preprint2010arXiv

A Near Infrared Laser Frequency Comb for High Precision Doppler Planet Surveys

We discuss the laser frequency comb as a near infrared astronomical wavelength reference, and describe progress towards a near infrared laser frequency comb at the National Institute of Standards and Technology and at the University of Colorado where we are operating a laser frequency comb suitable for use with a high resolution H band astronomical spectrograph.

preprint2010arXiv

The Cosmic Origins Spectrograph: On-Orbit Instrument Performance

The Cosmic Origins Spectrograph (COS) was installed in the Hubble Space Telescope in May, 2009 as part of Servicing Mission 4 to provide high sensitivity, medium and low resolution spectroscopy at far- and near-ultraviolet wavelengths (FUV, NUV). COS is the most sensitive FUV/NUV spectrograph flown to date, spanning the wavelength range from 900Å to 3200Å with peak effective area approaching 3000 cm^2. This paper describes instrument design, the results of the Servicing Mission Orbital Verification (SMOV), and the ongoing performance monitoring program.