Source author record

S. Kroker

S. Kroker appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

4works
6topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2020arXiv

Thermal charge carrier driven noise in transmissive semiconductor optics

Several sources of noise limit the sensitivity of current gravitational wave detectors. Currently, dominant noise sources include quantum noise and thermal Brownian noise, but future detectors will also be limited by other thermal noise channels. In this paper we study a thermal noise source which is caused by spatial charge carrier density variations in semiconductor materials. We provide an analytical model for the understanding of charge carrier fluctuations under the presence of screening effects and show that charge carrier noise will not be a limiting noise source for third generation gravitational wave detectors.

preprint2015arXiv

Upper Limit to the Transverse to Longitudinal Motion Coupling of a Waveguide Mirror

Waveguide mirrors possess nano-structured surfaces which can potentially provide a significant reduction in thermal noise over conventional dielectric mirrors. To avoid introducing additional phase noise from motion of the mirror transverse to the reflected light, however, they must possess a mechanism to suppress the phase effects associated with the incident light translating across the nano-structured surface. It has been shown that with carefully chosen parameters this additional phase noise can be suppressed. We present an experimental measurement of the coupling of transverse to longitudinal displacements in such a waveguide mirror designed for 1064 nm light. We place an upper limit on the level of measured transverse to longitudinal coupling of one part in seventeen thousand with 95% confidence, representing a significant improvement over a previously measured grating mirror.

preprint2012arXiv

Scientific Objectives of Einstein Telescope

The advanced interferometer network will herald a new era in observational astronomy. There is a very strong science case to go beyond the advanced detector network and build detectors that operate in a frequency range from 1 Hz-10 kHz, with sensitivity a factor ten better in amplitude. Such detectors will be able to probe a range of topics in nuclear physics, astronomy, cosmology and fundamental physics, providing insights into many unsolved problems in these areas.

preprint2010arXiv

Investigation of mechanical losses of thin silicon flexures at low temperatures

The investigation of the mechanical loss of different silicon flexures in a temperature region from 5 to 300 K is presented. The flexures have been prepared by different fabrication techniques. A lowest mechanical loss of $3\times10^{-8}$ was observed for a 130 $μ$m thick flexure at around 10 K. While the mechanical loss follows the thermoelastic predictions down to 50 K a difference can be observed at lower temperatures for different surface treatments. This surface loss will be limiting for all applications using silicon based oscillators at low temperatures. The extraction of a surface loss parameter using different results from our measurements and other references is presented. We focused on structures that are relevant for gravitational wave detectors. The surface loss parameter $α_s$ = 0.5 pm was obtained. This reveals that the surface loss of silicon is significantly lower than the surface loss of fused silica.