Researcher profile

S. Jetter

S. Jetter contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
12works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

12 published item(s)

preprint2016arXiv

New measurement of $θ_{13}$ via neutron capture on hydrogen at Daya Bay

This article reports an improved independent measurement of neutrino mixing angle $θ_{13}$ at the Daya Bay Reactor Neutrino Experiment. Electron antineutrinos were identified by inverse $β$-decays with the emitted neutron captured by hydrogen, yielding a data-set with principally distinct uncertainties from that with neutrons captured by gadolinium. With the final two of eight antineutrino detectors installed, this study used 621 days of data including the previously reported 217-day data set with six detectors. The dominant statistical uncertainty was reduced by 49%. Intensive studies of the cosmogenic muon-induced $^9$Li and fast neutron backgrounds and the neutron-capture energy selection efficiency, resulted in a reduction of the systematic uncertainty by 26%. The deficit in the detected number of antineutrinos at the far detectors relative to the expected number based on the near detectors yielded $\sin^22θ_{13} = 0.071 \pm 0.011$ in the three-neutrino-oscillation framework. The combination of this result with the gadolinium-capture result is also reported.

preprint2016arXiv

Study of the wave packet treatment of neutrino oscillation at Daya Bay

The disappearance of reactor $\barν_e$ observed by the Daya Bay experiment is examined in the framework of a model in which the neutrino is described by a wave packet with a relative intrinsic momentum dispersion $σ_\text{rel}$. Three pairs of nuclear reactors and eight antineutrino detectors, each with good energy resolution, distributed among three experimental halls, supply a high-statistics sample of $\barν_e$ acquired at nine different baselines. This provides a unique platform to test the effects which arise from the wave packet treatment of neutrino oscillation. The modified survival probability formula was used to fit Daya Bay data, providing the first experimental limits: $2.38 \cdot 10^{-17} < σ_{\rm rel} < 0.23$. Treating the dimensions of the reactor cores and detectors as constraints, the limits are improved: $10^{-14} \lesssim σ_{\rm rel} < 0.23$, and an upper limit of $σ_{\rm rel} <0.20$ is obtained. All limits correspond to a 95\% C.L. Furthermore, the effect due to the wave packet nature of neutrino oscillation is found to be insignificant for reactor antineutrinos detected by the Daya Bay experiment thus ensuring an unbiased measurement of the oscillation parameters $\sin^22θ_{13}$ and $Δm^2_{32}$ within the plane wave model.

preprint2016arXiv

The Detector System of The Daya Bay Reactor Neutrino Experiment

The Daya Bay experiment was the first to report simultaneous measurements of reactor antineutrinos at multiple baselines leading to the discovery of $\barν_e$ oscillations over km-baselines. Subsequent data has provided the world&#39;s most precise measurement of $\rm{sin}^22θ_{13}$ and the effective mass splitting $Δm_{ee}^2$. The experiment is located in Daya Bay, China where the cluster of six nuclear reactors is among the world&#39;s most prolific sources of electron antineutrinos. Multiple antineutrino detectors are deployed in three underground water pools at different distances from the reactor cores to search for deviations in the antineutrino rate and energy spectrum due to neutrino mixing. Instrumented with photomultiplier tubes (PMTs), the water pools serve as shielding against natural radioactivity from the surrounding rock and provide efficient muon tagging. Arrays of resistive plate chambers over the top of each pool provide additional muon detection. The antineutrino detectors were specifically designed for measurements of the antineutrino flux with minimal systematic uncertainty. Relative detector efficiencies between the near and far detectors are known to better than 0.2%. With the unblinding of the final two detectors&#39; baselines and target masses, a complete description and comparison of the eight antineutrino detectors can now be presented. This paper describes the Daya Bay detector systems, consisting of eight antineutrino detectors in three instrumented water pools in three underground halls, and their operation through the first year of eight detector data-taking.

preprint2015arXiv

A new measurement of antineutrino oscillation with the full detector configuration at Daya Bay

We report a new measurement of electron antineutrino disappearance using the fully-constructed Daya Bay Reactor Neutrino Experiment. The final two of eight antineutrino detectors were installed in the summer of 2012. Including the 404 days of data collected from October 2012 to November 2013 resulted in a total exposure of 6.9$\times$10$^5$ GW$_{\rm th}$-ton-days, a 3.6 times increase over our previous results. Improvements in energy calibration limited variations between detectors to 0.2%. Removal of six $^{241}$Am-$^{13}$C radioactive calibration sources reduced the background by a factor of two for the detectors in the experimental hall furthest from the reactors. Direct prediction of the antineutrino signal in the far detectors based on the measurements in the near detectors explicitly minimized the dependence of the measurement on models of reactor antineutrino emission. The uncertainties in our estimates of $\sin^{2}2θ_{13}$ and $|Δm^2_{ee}|$ were halved as a result of these improvements. Analysis of the relative antineutrino rates and energy spectra between detectors gave $\sin^{2}2θ_{13} = 0.084\pm0.005$ and $|Δm^{2}_{ee}|= (2.42\pm0.11) \times 10^{-3}$ eV$^2$ in the three-neutrino framework.

preprint2015arXiv

JUNO Conceptual Design Report

The Jiangmen Underground Neutrino Observatory (JUNO) is proposed to determine the neutrino mass hierarchy using an underground liquid scintillator detector. It is located 53 km away from both Yangjiang and Taishan Nuclear Power Plants in Guangdong, China. The experimental hall, spanning more than 50 meters, is under a granite mountain of over 700 m overburden. Within six years of running, the detection of reactor antineutrinos can resolve the neutrino mass hierarchy at a confidence level of 3-4$σ$, and determine neutrino oscillation parameters $\sin^2θ_{12}$, $Δm^2_{21}$, and $|Δm^2_{ee}|$ to an accuracy of better than 1%. The JUNO detector can be also used to study terrestrial and extra-terrestrial neutrinos and new physics beyond the Standard Model. The central detector contains 20,000 tons liquid scintillator with an acrylic sphere of 35 m in diameter. $\sim$17,000 508-mm diameter PMTs with high quantum efficiency provide $\sim$75% optical coverage. The current choice of the liquid scintillator is: linear alkyl benzene (LAB) as the solvent, plus PPO as the scintillation fluor and a wavelength-shifter (Bis-MSB). The number of detected photoelectrons per MeV is larger than 1,100 and the energy resolution is expected to be 3% at 1 MeV. The calibration system is designed to deploy multiple sources to cover the entire energy range of reactor antineutrinos, and to achieve a full-volume position coverage inside the detector. The veto system is used for muon detection, muon induced background study and reduction. It consists of a Water Cherenkov detector and a Top Tracker system. The readout system, the detector control system and the offline system insure efficient and stable data acquisition and processing.

preprint2015arXiv

Measurement of the Reactor Antineutrino Flux and Spectrum at Daya Bay

This Letter reports a measurement of the flux and energy spectrum of electron antineutrinos from six 2.9~GW$_{th}$ nuclear reactors with six detectors deployed in two near (effective baselines 512~m and 561~m) and one far (1,579~m) underground experimental halls in the Daya Bay experiment. Using 217 days of data, 296,721 and 41,589 inverse beta decay (IBD) candidates were detected in the near and far halls, respectively. The measured IBD yield is (1.55 $\pm$ 0.04) $\times$ 10$^{-18}$~cm$^2$/GW/day or (5.92 $\pm$ 0.14) $\times$ 10$^{-43}$~cm$^2$/fission. This flux measurement is consistent with previous short-baseline reactor antineutrino experiments and is $0.946\pm0.022$ ($0.991\pm0.023$) relative to the flux predicted with the Huber+Mueller (ILL+Vogel) fissile antineutrino model. The measured IBD positron energy spectrum deviates from both spectral predictions by more than 2$σ$ over the full energy range with a local significance of up to $\sim$4$σ$ between 4-6 MeV. A reactor antineutrino spectrum of IBD reactions is extracted from the measured positron energy spectrum for model-independent predictions.

preprint2014arXiv

Independent Measurement of Theta13 via Neutron Capture on Hydrogen at Daya Bay

A new measurement of the $θ_{13}$ mixing angle has been obtained at the Daya Bay Reactor Neutrino Experiment via the detection of inverse beta decays tagged by neutron capture on hydrogen. The antineutrino events for hydrogen capture are distinct from those for gadolinium capture with largely different systematic uncertainties, allowing a determination independent of the gadolinium-capture result and an improvement on the precision of $θ_{13}$ measurement. With a 217-day antineutrino data set obtained with six antineutrino detectors and from six 2.9 GW$_{th}$ reactors, the rate deficit observed at the far hall is interpreted as $\sin^22θ_{13}=0.083\pm0.018$ in the three-flavor oscillation model. When combined with the gadolinium-capture result from Daya Bay, we obtain $\sin^22θ_{13}=0.089\pm0.008$ as the final result for the six-antineutrino-detector configuration of the Daya Bay experiment.

preprint2014arXiv

Search for a Light Sterile Neutrino at Daya Bay

A search for light sterile neutrino mixing was performed with the first 217 days of data from the Daya Bay Reactor Antineutrino Experiment. The experiment&#39;s unique configuration of multiple baselines from six 2.9~GW$_{\rm th}$ nuclear reactors to six antineutrino detectors deployed in two near (effective baselines 512~m and 561~m) and one far (1579~m) underground experimental halls makes it possible to test for oscillations to a fourth (sterile) neutrino in the $10^{\rm -3}~{\rm eV}^{2} < |Δm_{41}^{2}| < 0.3~{\rm eV}^{2}$ range. The relative spectral distortion due to electron antineutrino disappearance was found to be consistent with that of the three-flavor oscillation model. The derived limits on $\sin^22θ_{14}$ cover the $10^{-3}~{\rm eV}^{2} \lesssim |Δm^{2}_{41}| \lesssim 0.1~{\rm eV}^{2}$ region, which was largely unexplored.

preprint2014arXiv

Spectral measurement of electron antineutrino oscillation amplitude and frequency at Daya Bay

A measurement of the energy dependence of antineutrino disappearance at the Daya Bay Reactor Neutrino Experiment is reported. Electron antineutrinos ($\overlineν_{e}$) from six $2.9$ GW$_{\rm th}$ reactors were detected with six detectors deployed in two near (effective baselines 512 m and 561 m) and one far (1579 m) underground experimental halls. Using 217 days of data, 41589 (203809 and 92912) antineutrino candidates were detected in the far hall (near halls). An improved measurement of the oscillation amplitude $\sin^{2}2θ_{13} = 0.090^{+0.008}_{-0.009} $ and the first direct measurement of the $\overlineν_{e}$ mass-squared difference $|Δm^{2}_{ee}|= (2.59_{-0.20}^{+0.19}) \times 10^{-3}\ {\rm eV}^2 $ is obtained using the observed $\overlineν_{e}$ rates and energy spectra in a three-neutrino framework. This value of $|Δm^{2}_{ee}|$ is consistent with $|Δm^{2}_{μμ}|$ measured by muon neutrino disappearance, supporting the three-flavor oscillation model.

preprint2012arXiv

A side-by-side comparison of Daya Bay antineutrino detectors

The Daya Bay Reactor Neutrino Experiment is designed to determine precisely the neutrino mixing angle $θ_{13}$ with a sensitivity better than 0.01 in the parameter sin$^22θ_{13}$ at the 90% confidence level. To achieve this goal, the collaboration will build eight functionally identical antineutrino detectors. The first two detectors have been constructed, installed and commissioned in Experimental Hall 1, with steady data-taking beginning September 23, 2011. A comparison of the data collected over the subsequent three months indicates that the detectors are functionally identical, and that detector-related systematic uncertainties exceed requirements.

preprint2012arXiv

Improved Measurement of Electron Antineutrino Disappearance at Daya Bay

We report an improved measurement of the neutrino mixing angle $θ_{13}$ from the Daya Bay Reactor Neutrino Experiment. We exclude a zero value for $\sin^22θ_{13}$ with a significance of 7.7 standard deviations. Electron antineutrinos from six reactors of 2.9 GW$_{\rm th}$ were detected in six antineutrino detectors deployed in two near (flux-weighted baselines of 470 m and 576 m) and one far (1648 m) underground experimental halls. Using 139 days of data, 28909 (205308) electron antineutrino candidates were detected at the far hall (near halls). The ratio of the observed to the expected number of antineutrinos assuming no oscillations at the far hall is $0.944\pm 0.007({\rm stat.}) \pm 0.003({\rm syst.})$. An analysis of the relative rates in six detectors finds $\sin^22θ_{13}=0.089\pm 0.010({\rm stat.})\pm0.005({\rm syst.})$ in a three-neutrino framework.

preprint2012arXiv

Observation of electron-antineutrino disappearance at Daya Bay

The Daya Bay Reactor Neutrino Experiment has measured a non-zero value for the neutrino mixing angle $θ_{13}$ with a significance of 5.2 standard deviations. Antineutrinos from six 2.9 GW$_{\rm th}$ reactors were detected in six antineutrino detectors deployed in two near (flux-weighted baseline 470 m and 576 m) and one far (1648 m) underground experimental halls. With a 43,000 ton-GW_{\rm th}-day livetime exposure in 55 days, 10416 (80376) electron antineutrino candidates were detected at the far hall (near halls). The ratio of the observed to expected number of antineutrinos at the far hall is $R=0.940\pm 0.011({\rm stat}) \pm 0.004({\rm syst})$. A rate-only analysis finds $\sin^22θ_{13}=0.092\pm 0.016({\rm stat})\pm0.005({\rm syst})$ in a three-neutrino framework.