Source author record

S. E. Brunner

S. E. Brunner appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

5works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2015arXiv

Recovery Time Measurements of Silicon Photomultipliers Using a Pulsed Laser

We performed an experimental study to determine the pixel recovery time of various Multi Pixel Photon Counters (MPPCs) in order to characterize their rate capability and double-hit resolution. The recovery time constant and its dependence on the operating voltage has been evaluated by measuring the photosensor response to two consecutive laser pulses with varying relative time differences of a few ns (2-3 ns) up to some 100 ns using a waveform analysis technique. A Monte Carlo simulation tool is being developed to model the MPPC recovery process and interpret experimental data. In this context, the influence of after-pulsing, cross-talk and dark-noise on the recovery process can be studied.

preprint2014arXiv

Time resolution below 100 ps for the SciTil detector of PANDA employing SiPM

The barrel time-of-flight (TOF) detector for the PANDA experiment at FAIR in Darmstadt is planned as a scintillator tile hodoscope (SciTil) using 8000 small scintillator tiles. It will provide fast event timing for a software trigger in the otherwise trigger-less data acquisition scheme of PANDA, relative timing in a multiple track event topology as well as additional particle identification in the low momentum region. The goal is to achieve a time resolution of sigma ~ 100 ps. We have conducted measurements using organic scintillators coupled to Silicon Photomultipliers (SiPM). The results are encouraging such that we are confident to reach the required time resolution.

preprint2013arXiv

Over saturation behavior of SiPMs at high photon exposure

Several types of Silicon Photomultipliers were exposed to short pulsed laser light (~ 30 ps FWHM) with its intensity varying from single photon to well above the number of microcells of the device. We observed a significant deviation of the output of SiPMs from the expected behavior although such response curve is considered to be rather trivial. We also noticed that the output exceeds the maximum expected pulse height, which should be defined as the total number of pixels times the single photon pulse height. At the highest light intensity (~ 500 times the number of pixels) that we tested, the signal output reached up to twice the maximum theoretical pulse height, and still did not fully saturate.

preprint2013arXiv

Studies on the Cherenkov Effect for Improved Time Resolution of TOF-PET

With the newly gained interest in the time of flight method for positron emission tomography (TOF-PET), many options for pushing the time resolution to its borders have been investigated. As one of these options the exploitation of the Cherenkov effect has been proposed, since it allows to bypass the scintillation process and therefore provides almost instantaneous response to incident 511keV annihilation photons. Our simulation studies on the yield of Cherenkov photons, their arrival rate at the photon detector and their angular distribution reveal a significant influence by Cherenkov photons on the rise time of inorganic scintillators - a key-parameter for TOF in PET. A measurement shows the feasibility to detect Cherenkov photons in this low energy range.

preprint2011arXiv

Position sensitive SiPM detector for Cherenkov applications

A prototype of a position sensitive photo-detector with 5.6 x 5.6 cm2 detection area readout with 64 Hamamatsu MPPCs (S10931-100P) with 3 x 3 mm2 active area each has been built and tested. The photo-sensors are arranged in a 8 x 8 array with a quadratic mirror light guide on top. The module is currently readout by in-house developed preamplifier boards but employing existing ASIC chips optimized for SiPM readout is also planned. Such a device is one of the candidates to be used for photon detection in the PANDA DIRC detectors.