Researcher profile

Rowan M. Thomson

Rowan M. Thomson contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 19 - UnverifiedVerification L1Unclaimed author
5works
0followers
1topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

5 published item(s)

preprint2022arXiv

Fast full patient and radioisotope Monte Carlo simulations of targeted radionuclide therapy: introducing egs_mird

BACKGROUND: Targeted Radionuclide Therapy (TRT) is a fast-growing field garnering much interest, however, dosimetry calculation techniques remain relatively simple. PURPOSE: To introduce egs_mird, a new Monte Carlo application built in EGSnrc which allows users to model full patient tissue and density (using clinical CT images) and radionuclide distribution (using clinical PET images) for fast and detailed TRT dose calculation. METHODS: The novel application egs_mird is introduced, including its structure and variation reduction approaches. A new egs++ source class egs_internal_source and a modified version of egs_radionuclide_source are described. The new code is compared to other MC calculations of S-value kernels, along with self-validation using the electron Fano test. Full patient prostate 177Lu TRT cancer treatment simulations are performed using a single set of patient DICOM CT and [18F]-DCFPyL PET data. RESULTS: Good agreement is found between S-value kernels calculated using egs_mird and those found in the literature. The Fano test is satisfied to 0.1%. Patient prostate, rectum, bone marrow, and bladder dose volume histogram results did not vary significantly when using the track-length estimator and not modelling electron transport, modelling bone marrow explicitly (rather than using generic tissue compositions), and reducing activity to voxels containing partial or full calcifications to half or none, respectively. Simulations using the track-length estimator can be completed in under 15 minutes. CONCLUSION: This work shows egs mird to be a reliable MC code for computing TRT doses as realistically as the patient CT and PET data allow, supporting the use of egs mird for dose calculations in TRT.

preprint2021arXiv

Technical Note: MC-GPU breast dosimetry validations with other Monte Carlo codes and Phase Space File implementation

Purpose: To validate the MC-GPU Monte Carlo code for dosimetric studies in x-ray breast imaging modalities: mammography, digital breast tomosynthesis, contrast enhanced digital mammography and breast-CT. Moreover, to implement and validate a phase space file generation routine. Methods: The MC-GPU code (v. 1.5 DBT) was modified in order to generate phase space files and to be compatible with PENELOPE v. 2018 derived cross section database. Simulations were performed with homogeneous and anthropomorphic breast phantoms for different breast imaging techniques. The glandular dose was computed for each case and compared with results from the PENELOPE (v. 2014) + penEasy (v. 2015) and egs brachy (EGSnrc) Monte Carlo codes. Afterwards, several phase space files were generated with MC-GPU and the scored photon spectra were compared between the codes. Results: MC-GPU showed good agreement with the other codes when calculating the glandular dose distribution for mammography, mean glandular dose for digital breast tomosynthesis, and normalized glandular dose for breast-CT. The latter case showed average/maximum relative differences of 2.3%/27%, respectively, compared to other literature works, with the larger differences observed at low energies (around 10 keV). The recorded photon spectra entering a voxel were similar (within statistical uncertainties) between the three Monte Carlo codes. Conclusions: The results indicate that MC-GPU code is suitable for breast dosimetric studies for different x-ray breast imaging modalities, with the advantage of a high performance. The phase space file implementation was validated and is compatible with the IAEA standard, allowing multiscale Monte Carlo simulations with a combination of CPU and GPU codes.

preprint2020arXiv

Heterogeneous multiscale Monte Carlo simulations for gold nanoparticle radiosensitization

To introduce the heterogeneous multiscale (HetMS) model for Monte Carlo simulations of gold nanoparticle dose-enhanced radiation therapy (GNPT), a model characterized by its varying levels of detail on different length scales within a single phantom; to apply the HetMS model in two different scenarios relevant for GNPT and to compare computed results with others published. The HetMS model is implemented in EGSnrc; the code is tested via comparisons with published data from independent gold nanoparticle (GNP) simulations. Two distinct scenarios for the HetMS model are considered: (1) monoenergetic photon beams incident on a large cylinder; (2) isotropic point source at the center of a large sphere with GNPs diffusing from the center. Dose enhancement factors (DEFs) are compared for different source energies, depths, gold concentrations, GNP sizes, and modeling assumptions. Simulation efficiencies are investigated. The HetMS MC simulations account for the competing effects of photon fluence perturbation coupled with enhanced local energy deposition. DEFs are most sensitive to these effects for lower source energies, varying with distance from the source; DEFs below unity can occur at energies relevant for brachytherapy. Compared to discrete modeling of GNPs throughout the gold-containing volume, efficiencies are enhanced by up to a factor of 122 with the HetMS approach. For the spherical phantom, DEFs vary with time for diffusion, radionuclide, and radius. By combining geometric models of varying complexity on different length scales within a single simulation, the HetMS model can effectively account for both macroscopic and microscopic effects. Efficiency gains with the HetMS approach enable diverse calculations which would otherwise be prohibitively long. The HetMS model may be extended to diverse scenarios relevant for GNPT, providing further avenues for research and development.

preprint2020arXiv

Taking EGSnrc to new lows: Development of egs++ lattice geometry and testing with microscopic

Purpose: This work introduces a new lattice geometry library, egs_lattice, into the EGSnrc Monte Carlo code, which can be used for both modeling very large (previously unfeasible) quantities of geometries and establishing recursive boundary conditions. The reliability of egs_lattice, as well as EGSnrc in general, is cross-validated and tested. Methods: New Bravais, cubic, and hexagonal lattice geometries are defined in egs_lattice and their transport algorithms are described. Simulations of cells and Gold NanoParticle (GNP) containing cavities are implemented to compare to published Geant4-DNA and PENELOPE results. Recursive boundary conditions, implemented through a cubic lattice, are used to perform electron Fano cavity tests. Results: Lattices are successfully implemented in EGSnrc. EGSnrc calculated doses to cell cytoplasm and nucleus when irradiated by an internal electron source with a median difference of 0.6% compared to Geant4-DNA. EGSnrc calculated the ratio of dose to a microscopic cavity containing GNPs over dose to a cavity containing a homogeneous mixture of gold, and results generally agree (within 1%) with PENELOPE. The Fano test is passed (sub-0.1%) for all energies/ cells considered. Additionally, the recursive boundary conditions used for the Fano test provided a factor of over a million increase in efficiency in some cases. Conclusions: The egs_lattice geometry library, currently available as a pull request on the EGSnrc GitHub develop branch, is now freely accessible as open-source code. Lattice geometry implementations cross-validated with independent simulations in other MC codes and verified with the electron Fano cavity test demonstrate not only the reliability of egs_lattice, but, by extension, EGSnrc's ability to simulate transport in nanometer geometries and score in microscopic cavities.

preprint2020arXiv

Update of the CLRP TG-43 parameter database for low-energy brachytherapy sources

PURPOSE: To update the Carleton Laboratory for Radiotherapy Physics (CLRP) TG-43 dosimetry database for low-energy (< 50 keV) photon-emitting low-dose rate (LDR) brachytherapy sources utilizing the open-source EGSnrc application egs_brachy rather than the BrachyDose application used previously for 27 LDR sources in the 2008 CLRP version (CLRPv1). CLRPv2 covers 40 sources (Pd-103, I-125, Cs-131). A comprehensive set of TG-43 parameters is calculated, including dose-rate constants, radial dose functions with functional fitting parameters, 1D and 2D anisotropy functions, along-away dose-rate tables, Primary-Scatter separation dose tables (for some sources), and mean photon energies. The database also documents the source models which will become part of the egs_brachy distribution. METHODS: Datasets are calculated after a systematic recoding of the source geometries using the egs++ geometry package and its egs_brachy extensions. Full scatter water phantoms with varying voxel resolutions in cylindrical coordinates are used for dose calculations. New statistical uncertainties of source volume corrections for phantom voxels which overlap with brachytherapy sources are implemented in egs_brachy, and all CLRPv2 data include these uncertainties. For validation, data are compared to CLRPv1 and other data in the literature. DATA ACCESS/FORMAT: Data are available at https://physics.carleton.ca/ clrp/egs_brachy/seed_database_v2. As well as being presented graphically in comparisons to previous calculations, data are available in Excel (.xlsx) spreadsheets for each source. APPLICATIONS: The database has applications in research, dosimetry, and brachytherapy planning. This comprehensive update provides the medical physics community with more accurate TG-43 dose evaluation parameters, as well as fully-benchmarked source models distributed with egs_brachy.