Researcher profile

Ronald Holzwarth

Ronald Holzwarth contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
6works
0followers
5topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2020arXiv

A crucial test for astronomical spectrograph calibration with frequency combs

Laser frequency combs (LFCs) are well on their way to becoming the next-generation calibration sources for precision astronomical spectroscopy. This development is considered key in the hunt for low-mass rocky exoplanets around solar-type stars whose discovery with the radial-velocity method requires cm/s Doppler precision. In order to prove such precise calibration with an LFC, it must be compared to another calibrator of at least the same precision. Being the best available spectrograph calibrator, this means comparing it to a second - fully independent - LFC. This test had long been pending, but our installation of two LFCs at the ultra-stable spectrograph HARPS presented the so far unique opportunity for simultaneous calibrations with two separate LFCs. Although limited in time, the test results confirm the 1 cm/s stability that has long been anticipated by the astronomical community.

preprint2020arXiv

Performance Verification of the EXtreme PREcision Spectrograph

The EXtreme PREcision Spectrograph (EXPRES) is a new Doppler spectrograph designed to reach a radial velocity measurement precision sufficient to detect Earth-like exoplanets orbiting nearby, bright stars. We report on extensive laboratory testing and on-sky observations to quantitatively assess the instrumental radial velocity measurement precision of EXPRES, with a focused discussion of individual terms in the instrument error budget. We find that EXPRES can reach a single-measurement instrument calibration precision better than 10 cm/s, not including photon noise from stellar observations. We also report on the performance of the various environmental, mechanical, and optical subsystems of EXPRES, assessing any contributions to radial velocity error. For atmospheric and telescope related effects, this includes the fast tip-tilt guiding system, atmospheric dispersion compensation, and the chromatic exposure meter. For instrument calibration, this includes the laser frequency comb (LFC), flat-field light source, CCD detector, and effects in the optical fibers. Modal noise is mitigated to a negligible level via a chaotic fiber agitator, which is especially important for wavelength calibration with the LFC. Regarding detector effects, we empirically assess the impact on radial velocity precision due to pixel-position non-uniformities (PPNU) and charge transfer inefficiency (CTI). EXPRES has begun its science survey to discover exoplanets orbiting G-dwarf and K-dwarf stars, in addition to transit spectroscopy and measurements of the Rossiter-McLaughlin effect.

preprint2019arXiv

Quantum cascade laser-pumped terahertz molecular lasers: frequency noise and phase-locking using a 1560nm frequency comb

The recent demonstration of a terahertz (THz) molecular gas laser pumped by a mid-infrared quantum cascade laser (QCL) has opened up new perspectives for this family of sources, traditionally relying on CO2-laser pumping. A so far open question concerning QCL-pumped THz molecular lasers (MLs) is related to their spectral purity. Indeed, assessing their frequency/phase noise is crucial for a number of applications potentially exploiting these sources as local oscillators. Here this question is addressed by reporting the measurement of the frequency noise power spectral density (PSD) of a THz ML pumped by a 10.3μm-wavelength QCL, and emitting 1mW at 1.1THz in continuous wave. This is achieved by beating the ML frequency with the 1080th harmonic of the repetition rate of a 1560nm frequency comb. We find a frequency noise PSD < 10Hz2/Hz (-95dBc/Hz) at 100kHz from the carrier. To demonstrate the effect of the stability of the pump laser on the spectral purity of the THz emission we also measure the frequency noise PSD of a CO2-laser-pumped 2.5THz ML, reaching 0.1Hz2/Hz (-105dBc/Hz) at 40kHz from the carrier, limited by the frequency noise of the frequency comb harmonic. Finally, we show that it is possible to actively phase-lock the QCL-pumped molecular laser to the frequency comb repetition rate harmonic by controlling the QCL current, demonstrating a sub-Hz linewidth.

preprint2011arXiv

Improved Measurement of the Hydrogen 1S - 2S Transition Frequency

We have measured the 1S - 2S transition frequency in atomic hydrogen via two photon spectroscopy on a 5.8 K atomic beam. We obtain $f_{1S-2S} = 2 466 061 413 187 035 (10)$ Hz for the hyperfine centroid. This is a fractional frequency uncertainty of $4.2\times 10^{-15}$ improving the previous measure- ment by our own group [M. Fischer et al., Phys. Rev. Lett. 92, 230802 (2004)] by a factor of 3.3. The probe laser frequency was phase coherently linked to the mobile cesium fountain clock FOM via a frequency comb.

preprint2009arXiv

Cavity-enhanced dual-comb spectroscopy

The sensitivity of molecular fingerprinting is dramatically improved when placing the absorbing sample in a high-finesse optical cavity, thanks to the large increase of the effective path-length. As demonstrated recently, when the equidistant lines from a laser frequency comb are simultaneously injected into the cavity over a large spectral range, multiple trace-gases may be identified within a few milliseconds. Analyzing efficiently the light transmitted through the cavity however still remains challenging. Here, a novel approach, cavity-enhanced frequency comb Fourier transform spectroscopy, fully overcomes this difficulty and measures ultrasensitive, broad-bandwidth, high-resolution spectra within a few tens of $μ$s. It could be implemented from the Terahertz to the ultraviolet regions without any need for detector arrays. We recorded, within 18 $μ$s, spectra of the 1.0 $μ$m overtone bands of ammonia spanning 20 nm with 4.5 GHz resolution and a noise-equivalent-absorption at one-second-averaging per spectral element of 3 10^-12 cm^-1Hz^-1/2, thus opening a route to time-resolved spectroscopy of rapidly-evolving single-events.

preprint2009arXiv

Phase- coherent comparison of two optical frequency standards over 146 km using a telecommunication fiber link

We have explored the performance of two &#34;dark fibers&#34; of a commercial telecommunication fiber link for a remote comparison of optical clocks. The two fibers, linking the Leibniz University of Hanover (LUH) with the Physi-kalisch-Technische Bundesanstalt (PTB) in Braunschweig, are connected in Hanover to form a total fiber length of 146 km. At PTB the performance of an optical frequency standard operating at 456 THz was imprinted to a cw trans-fer laser at 194 THz, and its frequency was transmitted over the fiber. In order to detect and compensate phase noise related to the optical fiber link we have built a low-noise optical fiber interferometer and investigated noise sources that affect the overall performance of the optical link. The frequency stability at the remote end has been measured using the clock laser of PTB&#39;s Yb+ frequency standard operating at 344 THz. We show that the frequency of a frequency-stabilized fiber laser can be transmitted over a total fiber length of 146 km with a relative frequency uncertainty below 1E-19, and short term frequency instability given by the fractional Allan deviation of sy(t)=3.3E-15/(t/s).