Source author record

Robert Content

Robert Content appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

4works
5topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

4 published item(s)

preprint2020arXiv

White Paper on MAAT@GTC

MAAT is proposed as a visitor mirror-slicer optical system that will allow the OSIRIS spectrograph on the 10.4-m Gran telescopio CANARIAS (GTC) the capability to perform Integral Field Spectroscopy (IFS) over a seeing-limited FoV 14.20''x10'' with a slice width of 0.303''. MAAT@GTC will enhance the resolution power of OSIRIS by 1.6 times as compared to its 0.6'' wide long-slit. All the eleven OSIRIS grisms and volume-phase holographic gratings will be available to provide broad spectral coverage with moderate resolution (R=600 up to 4100) in the 3600 - 10000 Å wavelength range. MAAT unique observing capabilities will broaden its use to the needs of the GTC community to unveil the nature of most striking phenomena in the universe well beyond time-domain astronomy. The GTC equipped with OSIRIS+MAAT will also play a fundamental role in synergy with other facilities, some of them operating on the northern ORM at La Palma. This White Paper presents the different aspects of MAAT@GTC - including scientific and technical specifications, outstanding science cases, and an outline of the instrument concept.

preprint2014arXiv

Photonic lantern behaviour and implications for instrument design

Photonic lanterns are an important enabling technology for astrophotonics with a wide range of potential applications including fibre Bragg grating OH suppression, integrated photonic spectrographs and fibre scramblers for high resolution spectroscopy. The behaviour of photonic lanterns differs in several important respects from the conventional fibre systems more frequently used in astronomical instruments and a detailed understanding of this behaviour is required in order to make the most effective use of this promising technology. To this end we have undertaken a laboratory study of photonic lanterns with the aim of developing an empirical model for the mapping from input to output illumination distributions. We have measured overall transmission and near field output light distributions as a function of input angle of incidence for photonic lanterns with between 19 and 61 cores. We present the results of this work, highlight the key differences between photonic lanterns and conventional fibres, and illustrate the implications for instrument design via a case study, the design of the PRAXIS spectrograph. The empirical photonic lantern model was incorporated into an end-to-end PRAXIS performance model which was used to optimise the design parameters of the instrument. We describe the methods used and the resulting conclusions. The details of photonic lantern behaviour proved particularly important in selecting the optimum on sky field of view per fibre and in modelling of the instrument thermal background.

preprint2014arXiv

PRAXIS: low thermal emission high efficiency OH suppressed fibre spectrograph

PRAXIS is a second generation instrument that follows on from GNOSIS, which was the first instrument using fibre Bragg gratings for OH background suppression. The Bragg gratings reflect the NIR OH lines while being transparent to light between the lines. This gives a much higher signal-noise ratio at low resolution but also at higher resolutions by removing the scattered wings of the OH lines. The specifications call for high throughput and very low thermal and detector noise so that PRAXIS will remain sky noise limited. The optical train is made of fore-optics, an IFU, a fibre bundle, the Bragg grating unit, a second fibre bundle and a spectrograph. GNOSIS used the pre-existing IRIS2 spectrograph while PRAXIS will use a new spectrograph specifically designed for the fibre Bragg grating OH suppression and optimised for 1470 nm to 1700 nm (it can also be used in the 1090 nm to 1260 nm band by changing the grating and refocussing). This results in a significantly higher transmission due to high efficiency coatings, a VPH grating at low incident angle and low absorption glasses. The detector noise will also be lower. Throughout the PRAXIS design special care was taken at every step along the optical path to reduce thermal emission or stop it leaking into the system. This made the spectrograph design challenging because practical constraints required that the detector and the spectrograph enclosures be physically separate by air at ambient temperature. At present, the instrument uses the GNOSIS fibre Bragg grating OH suppression unit. We intend to soon use a new OH suppression unit based on multicore fibre Bragg gratings which will allow increased field of view per fibre. Theoretical calculations show that the gain in interline sky background signal-noise ratio over GNOSIS may very well be as high as 9 with the GNOSIS OH suppression unit and 17 with the multicore fibre OH suppression unit.

preprint1999arXiv

Multiple object and integral field near-infrared spectroscopy using fibers

We describe a new system for multiple object spectroscopy and integral field spectroscopy at near-infrared wavelengths using optical fibers. Both modes of the SMIRFS instrument have been tested at the UK Infrared Telescope with the CGS4 infrared spectrograph. The modular system includes a common optical system to image the fiber slit onto the cold slit inside the CGS4 cryostat. The multiobject mode consists of 14 interchangeable fused silica or zirconium fluoride fibers each with a field of 4 arcsec. The integral field mode consists of 72 fused silica fibers coupled with a lenslet array to give a contiguous field of 6x4 arcsec with 0.6 arcsec sampling. We describe the performance of both modes. For the multiobject mode, the feasibility and desirability of using fluoride fibers to extend the wavelength range into the K-band is discussed. For the integral field mode, the performance is compared with theoretical expectation with particular attention to the effect of Focal Ratio Degradation in the fibers. These results demonstrate the feasibility of multiobject and integral field spectroscopy in the near-infrared using lenslet-coupled fiber systems. Although SMIRFS in an experimental system working with a spectrograph not designed for this purpose, the throughput and uniformity of response are good. SMIRFS points the way forward to systems with much larger numbers of elements.