Source author record

Roger Haynes

Roger Haynes appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

8works
6topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

8 published item(s)

preprint2016arXiv

Astronomical photonics in the context of infrared interferometry and high-resolution spectroscopy

We review the potential of Astrophotonics, a relatively young field at the interface between photonics and astronomical instrumentation, for spectro-interferometry. We review some fundamental aspects of photonic science that drove the emer- gence of astrophotonics, and highlight the achievements in observational astrophysics. We analyze the prospects for further technological development also considering the potential synergies with other fields of physics (e.g. non-linear optics in condensed matter physics). We also stress the central role of fiber optics in routing and transporting light, delivering complex filters, or interfacing instruments and telescopes, more specifically in the context of a growing usage of adaptive optics.

preprint2016arXiv

The Potsdam MRS Spectrograph - heritage of MUSE and the impact of cross-innovation in the process of technology transfer

After having demonstrated that an IFU, attached to a microscope rather than to a telescope, is capable of differentiating complex organic tissue with spatially resolved Raman spectroscopy, we have launched a clinical validation program that utilizes a novel optimized fiber-coupled multi-channel spectrograph whose layout is based on the modular MUSE spectrograph concept. The new design features a telecentric input and has an extended blue performance, but otherwise maintains the properties of high throughput and excellent image quality over an octave of wavelength coverage with modest spectral resolution. We present the opto-mechanical layout and details of its optical performance.

preprint2014arXiv

PRAXIS: low thermal emission high efficiency OH suppressed fibre spectrograph

PRAXIS is a second generation instrument that follows on from GNOSIS, which was the first instrument using fibre Bragg gratings for OH background suppression. The Bragg gratings reflect the NIR OH lines while being transparent to light between the lines. This gives a much higher signal-noise ratio at low resolution but also at higher resolutions by removing the scattered wings of the OH lines. The specifications call for high throughput and very low thermal and detector noise so that PRAXIS will remain sky noise limited. The optical train is made of fore-optics, an IFU, a fibre bundle, the Bragg grating unit, a second fibre bundle and a spectrograph. GNOSIS used the pre-existing IRIS2 spectrograph while PRAXIS will use a new spectrograph specifically designed for the fibre Bragg grating OH suppression and optimised for 1470 nm to 1700 nm (it can also be used in the 1090 nm to 1260 nm band by changing the grating and refocussing). This results in a significantly higher transmission due to high efficiency coatings, a VPH grating at low incident angle and low absorption glasses. The detector noise will also be lower. Throughout the PRAXIS design special care was taken at every step along the optical path to reduce thermal emission or stop it leaking into the system. This made the spectrograph design challenging because practical constraints required that the detector and the spectrograph enclosures be physically separate by air at ambient temperature. At present, the instrument uses the GNOSIS fibre Bragg grating OH suppression unit. We intend to soon use a new OH suppression unit based on multicore fibre Bragg gratings which will allow increased field of view per fibre. Theoretical calculations show that the gain in interline sky background signal-noise ratio over GNOSIS may very well be as high as 9 with the GNOSIS OH suppression unit and 17 with the multicore fibre OH suppression unit.

preprint2013arXiv

GNOSIS: the first instrument to use fibre Bragg gratings for OH suppression

GNOSIS is a prototype astrophotonic instrument that utilizes OH suppression fibres consisting of fibre Bragg gratings and photonic lanterns to suppress the 103 brightest atmospheric emission doublets between 1.47-1.7 microns. GNOSIS was commissioned at the 3.9-meter Anglo-Australian Telescope with the IRIS2 spectrograph to demonstrate the potential of OH suppression fibres, but may be potentially used with any telescope and spectrograph combination. Unlike previous atmospheric suppression techniques GNOSIS suppresses the lines before dispersion and in a manner that depends purely on wavelength. We present the instrument design and report the results of laboratory and on-sky tests from commissioning. While these tests demonstrated high throughput and excellent suppression of the skylines by the OH suppression fibres, surprisingly GNOSIS produced no significant reduction in the interline background and the sensitivity of GNOSIS and IRIS2 is about the same as IRIS2. It is unclear whether the lack of reduction in the interline background is due to physical sources or systematic errors as the observations are detector noise-dominated. OH suppression fibres could potentially impact ground-based astronomy at the level of adaptive optics or greater. However, until a clear reduction in the interline background and the corresponding increasing in sensitivity is demonstrated optimized OH suppression fibres paired with a fibre-fed spectrograph will at least provide a real benefits at low resolving powers.

preprint2012arXiv

4MOST - 4-metre Multi-Object Spectroscopic Telescope

The 4MOST consortium is currently halfway through a Conceptual Design study for ESO with the aim to develop a wide-field (>3 square degree, goal >5 square degree), high-multiplex (>1500 fibres, goal 3000 fibres) spectroscopic survey facility for an ESO 4m-class telescope (VISTA). 4MOST will run permanently on the telescope to perform a 5 year public survey yielding more than 20 million spectra at resolution R~5000 (λ=390-1000 nm) and more than 2 million spectra at R~20,000 (395-456.5 nm & 587-673 nm). The 4MOST design is especially intended to complement three key all-sky, space-based observatories of prime European interest: Gaia, eROSITA and Euclid. Initial design and performance estimates for the wide-field corrector concepts are presented. We consider two fibre positioner concepts, a well-known Phi-Theta system and a new R-Theta concept with a large patrol area. The spectrographs are fixed configuration two-arm spectrographs, with dedicated spectrographs for the high- and low-resolution. A full facility simulator is being developed to guide trade-off decisions regarding the optimal field-of-view, number of fibres needed, and the relative fraction of high-to-low resolution fibres. Mock catalogues with template spectra from seven Design Reference Surveys are simulated to verify the science requirements of 4MOST. The 4MOST consortium aims to deliver the full 4MOST facility by the end of 2018 and start delivering high-level data products for both consortium and ESO community targets a year later with yearly increments.

preprint2010arXiv

A SiC TMA GLAO design for PLT?

A 'PILOT-Like Telescope' is likely to have differences in science goals to the original PILOT. Furthermore, our understanding of the environmental conditions at Dome C has changed significantly since the start of the PILOT design study in June 2007. Therefore, it is timely to re-examine some of the basic design decisions. We present here one alternative concept: a silicon-carbide, GLAO-assisted, three-mirror anastigmat, and possibly equatorial, PILOT-Like-Telescope.

preprint2010arXiv

The Fibre Multi-Object Spectrograph (FMOS) for Subaru Telescope

Fibre Multi-Object Spectrograph (FMOS) is the first near-infrared instrument with a wide field of view capable of acquiring spectra simultaneously from up to 400 objects. It has been developed as a common-use instrument for the F/2 prime-focus of the Subaru Telescope. The field coverage of 30' diameter is achieved using a new 3-element corrector optimized in the near-infrared (0.9-1.8um) wavelength range. Due to limited space at the prime-focus, we have had to develop a novel fibre positioner called "Echidna" together with two OH-airglow suppressed spectrographs. FMOS consists of three subsystems: the prime focus unit for IR, the fibre positioning system/connector units, and the two spectrographs. After full systems integration, FMOS was installed on the telescope in late 2007. Many aspects of performance were checked through various test and engineering observations. In this paper, we present the optical and mechanical components of FMOS and show the results of our on-sky engineering observations to date.

preprint1999arXiv

Multiple object and integral field near-infrared spectroscopy using fibers

We describe a new system for multiple object spectroscopy and integral field spectroscopy at near-infrared wavelengths using optical fibers. Both modes of the SMIRFS instrument have been tested at the UK Infrared Telescope with the CGS4 infrared spectrograph. The modular system includes a common optical system to image the fiber slit onto the cold slit inside the CGS4 cryostat. The multiobject mode consists of 14 interchangeable fused silica or zirconium fluoride fibers each with a field of 4 arcsec. The integral field mode consists of 72 fused silica fibers coupled with a lenslet array to give a contiguous field of 6x4 arcsec with 0.6 arcsec sampling. We describe the performance of both modes. For the multiobject mode, the feasibility and desirability of using fluoride fibers to extend the wavelength range into the K-band is discussed. For the integral field mode, the performance is compared with theoretical expectation with particular attention to the effect of Focal Ratio Degradation in the fibers. These results demonstrate the feasibility of multiobject and integral field spectroscopy in the near-infrared using lenslet-coupled fiber systems. Although SMIRFS in an experimental system working with a spectrograph not designed for this purpose, the throughput and uniformity of response are good. SMIRFS points the way forward to systems with much larger numbers of elements.