Researcher profile

Reetam Sen Biswas

Reetam Sen Biswas contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
7works
0followers
4topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

7 published item(s)

preprint2022arXiv

State and Topology Estimation for Unobservable Distribution Systems using Deep Neural Networks

Time-synchronized state estimation for reconfigurable distribution networks is challenging because of limited real-time observability. This paper addresses this challenge by formulating a deep learning (DL)-based approach for topology identification (TI) and unbalanced three-phase distribution system state estimation (DSSE). Two deep neural networks (DNNs) are trained for time-synchronized DNN-based TI and DSSE, respectively, for systems that are incompletely observed by synchrophasor measurement devices (SMDs) in real-time. A data-driven approach for judicious SMD placement to facilitate reliable TI and DSSE is also provided. Robustness of the proposed methodology is demonstrated by considering non-Gaussian noise in the SMD measurements. A comparison of the DNN-based DSSE with more conventional approaches indicates that the DL-based approach gives better accuracy with smaller number of SMDs.

preprint2021arXiv

Time Synchronized State Estimation for Incompletely Observed Distribution Systems Using Deep Learning Considering Realistic Measurement Noise

Time-synchronized state estimation is a challenge for distribution systems because of limited real-time observability. This paper addresses this challenge by formulating a deep learning (DL)-based approach to perform unbalanced three-phase distribution system state estimation (DSSE). Initially, a data-driven approach for judicious measurement selection to facilitate reliable state estimation is provided. Then, a deep neural network (DNN) is trained to perform DSSE for systems that are incompletely observed by synchrophasor measurement devices (SMDs). Robustness of the proposed methodology is demonstrated by considering realistic measurement error models for SMDs. A comparative study of the DNN-based DSSE with classical linear state estimation indicates that the DL-based approach gives better accuracy with a significantly smaller number of SMDs.

preprint2020arXiv

A Graph Theoretic Approach to Power System Vulnerability Identification

During major power system disturbances, when multiple component outages occur in rapid succession, it becomes crucial to quickly identify the transmission interconnections that have limited power transfer capability. Understanding the impact of an outage on these critical interconnections (called saturated cut-sets) is important for enhancing situational awareness and taking correct actions. This paper proposes a new graph theoretic approach for analyzing whether a contingency will create a saturated cut-set in a meshed power network. A novel feature of the proposed algorithm is that it lowers the solution time significantly making the approach viable for real-time operations. It also indicates the minimum amount by which the power transfer through the critical interconnections should be reduced so that post-contingency saturation does not occur. Robustness of the proposed algorithm for enhanced situational awareness is demonstrated using the IEEE-118 bus system as well as a 17,000+ bus model of the Western Interconnection (WI). Comparisons made with different approaches for power system vulnerability assessment prove the utility of the proposed scheme for aiding power system operations during extreme exigencies.

preprint2020arXiv

A Micro-PMU Placement Scheme for Distribution Systems Considering Practical Constraints

This paper presents an innovative approach to micro-phasor measurement unit (micro-PMU) placement in unbalanced distribution networks. The methodology accounts for the presence of single-and-two-phase laterals and acknowledges the fact that observing one phase in a distribution circuit does not translate to observing the other phases. Other practical constraints such as presence of distributed loads, unknown regulator/ transformer tap ratios, zero-injection phases (ZIPs), modern smart meters, and multiple switch configurations are also incorporated. The proposed micro-PMU placement problem is solved using integer linear programming (ILP), guaranteeing optimality of results. The uniqueness of the developed algorithm is that it not only minimizes the micro-PMU installations, but also identifies the minimum number of phases that must be monitored by them.

preprint2020arXiv

Adaptive LVRT Settings Adjustment for Enhancing Voltage Security of Renewable-Rich Electric Grids

Inverter based renewable generation (RG), especially at the distribution level, is supposed to trip offline during an islanding situation. However, islanding detection is done by comparing the voltage and frequency measurements at the point of common coupling (PCC), with limits defined in the form of ride-through curves. Current practice is to use the same limit throughout the year independent of the operating conditions. This could result in the tripping of RG at times when the system is already weak, thereby posing a threat to voltage security by heavily limiting the load margin (LM). Conversely, heavily relaxing these limits would result in scenarios where the generation does not go offline even during an islanding situation. The proposed methodology focuses on optimizing low-voltage ride-through (LVRT) settings at selective RGs as a preventive control for maintaining a desired steady-state voltage stability margin while not sacrificing dependability during islanding. The proposed process is a multi-stage approach, in which at each stage, a subset of estimated poor-quality solutions is screened out based on various sensitivities. A full continuation power flow (CPFLOW) is only run at the beginning and in the last stage on a handful of remaining candidate solutions, thereby cutting down heavily on the computation time. The effectiveness of the approach is demonstrated on the IEEE 9-bus system.

preprint2020arXiv

Fast Identification of Saturated Cut-sets using Graph Search Techniques

When multiple outages occur in rapid succession, it is important to know quickly if the power transfer capability of different interconnections (or cut-sets) of the power network are limited. The algorithm developed in this paper identifies such limited cut-sets very fast, thereby enhancing the real-time situational awareness of power system operators. The significance of the proposed approach is described using the IEEE 39-bus test system, while its computational benefits are demonstrated using relatively large test-cases containing thousands of buses. The results indicate that the proposed network analysis can estimate the impact of an outage on any cut-set of the system and screen out the cut-set that gets saturated by the largest margin, very quickly.

preprint2020arXiv

Identification of Utility-Scale Renewable Energy Penetration Threshold in a Dynamic Setting

Integration of renewable energy resources with the electric grid is necessary for a sustainable energy future. However, increased penetration of inverter based resources (IBRs) reduce grid inertia, which might then compromise power system reliability. Therefore, power utilities are often interested in identifying the maximum IBR penetration limit for their system. The proposed research presents a methodology to identify the IBR penetration threshold beyond which voltage, frequency, and tie-line limits will be exceeded. The sensitivity of the IBR penetration threshold to momentary cessation due to low voltages, transmission versus distribution connected solar generation, and stalling of induction motors are also analyzed. Dynamic simulation studies conducted on a 24,000-bus model of the Western Interconnection (WI) demonstrate the practicality of the proposed approach.