Source author record

Ran Hong

Explore this author’s publications, collaborators and research topics. This catalog record has not been claimed by its author.

ResearcherUnclaimed source record

Catalog footprint

Research overview

4works
5topics
4close collaborators

Published work

4 publications

preprint2020arXiv

Magnetic Field Measurement and Analysis for the Muon g-2 Experiment

The Muon g-2 Experiment (E989) at Fermilab measures the muon magnetic anomaly, aiming to resolve the greater than 3σσ discrepancy between the previous measurement and the Standard Model calculation with an improved precision of 140 part-per-billion (ppb). In E989, the muon beam is stored in a ring magnet. The spin precession frequency ωaω_{a} is measured by counting the decay positrons in 24 calorimeters, and the magnetic field is measured by nuclear magnet resonance (NMR) probes. An in-vacuum field scanning system consisting of NMR probes and read-out electronics has been implemented to measure the magnetic field applied to the muon beam. An additional 378 NMR probes, placed at fixed locations outside the vacuum chamber, monitor the field drift in between field scans. A high-accuracy probe was designed for calibrating the probes in the scanner. In this presentation, the magnetic field measurement hardware system and analysis methods will be described in detail. The progress of the Run-1 data analysis and improvements in Run-2 will be presented as well.

preprint2016arXiv

Helicity and nuclear ββ decay correlations

We present simple derivations of nuclear ββ-decay correlations with an emphasis on the special role of helicity. This provides a good opportunity to teach students about helicity and chirality in particle physics through exercises using simple aspects of quantum mechanics. In addition, this paper serves as an introduction to nuclear ββ-decay correlations from both a theoretical and experimental vantage. This article can be used to introduce students to ongoing experiments searching for hints of new physics in the low-energy precision frontier.

preprint2016arXiv

High accuracy position response calibration method for a micro-channel plate ion detector

We have developed a position response calibration method for a micro-channel plate (MCP) detector with a delay-line anode position readout scheme. Using an {\em in situ} calibration mask, an accuracy of 8~μμm and a resolution of 85~μμm (FWHM) have been achieved for MeV-scale αα particles and ions with energies of ∼\sim10~keV. At this level of accuracy, the difference between the MCP position responses to high-energy αα particles and low-energy ions is significant. The improved performance of the MCP detector can find applications in many fields of AMO and nuclear physics. In our case, it helps reducing systematic uncertainties in a high-precision nuclear ββ-decay experiment.

preprint2013arXiv

Limits on tensor type weak currents from nuclear and neutron ββ~decays

The limits on time-reversal invariant tensor-type weak currents from nuclear and neutron ββ decays are evaluated including most recent experimental data. We find that −0.14×10−2<(CT+CT′)/CA<1.4×10−2 -0.14 \times 10^{-2} < (C_T + C^\prime_T)/C_A < 1.4 \times 10^{-2} and −0.16<(CT−CT′)/CA<0.16 -0.16 < (C_T - C^\prime_T)/C_A < 0.16 (90% C.L.), while for the case CT=CT′C_T = C^\prime_T the limits are ∣CT/CA∣<3.7×10−3 | C_T/C_A | < 3.7 \times 10^{-3} . These limits are shown to be more stringent than those from recent measurements of the radiative pion decay. In addition, the sensitivity of future 10−310^{-3}-level correlation measurements is investigated.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.