Source author record

Ralf Hertenberger

Ralf Hertenberger appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

7works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

7 published item(s)

preprint2016arXiv

Performance of Drift-Tube Detectors at High Counting Rates for High-Luminosity LHC Upgrades

The performance of pressurized drift-tube detectors at very high background rates has been studied at the Gamma Irradiation Facility (GIF) at CERN and in an intense 20 MeV proton beam at the Munich Van-der-Graaf tandem accelerator for applications in large-area precision muon tracking at high-luminosity upgrades of the Large Hadron Collider (LHC). The ATLAS muon drifttube (MDT) chambers with 30 mm tube diameter have been designed to cope with and neutron background hit rates of up to 500 Hz/square cm. Background rates of up to 14 kHz/square cm are expected at LHC upgrades. The test results with standard MDT readout electronics show that the reduction of the drift-tube diameter to 15 mm, while leaving the operating parameters unchanged, vastly increases the rate capability well beyond the requirements. The development of new small-diameter muon drift-tube (sMDT) chambers for LHC upgrades is completed. Further improvements of tracking efficiency and spatial resolution at high counting rates will be achieved with upgraded readout electronics employing improved signal shaping for high counting rates.

preprint2015arXiv

Broad levels in $^{17}$O and their relevance for the astrophysical s-process

Levels in $^{17}$O affect the astrophysical s-process in two opposite ways. The neutron production is enhanced by resonances in the $^{13}$C($α$,$n$)$^{16}$O reaction at excitation energies around 7 MeV in $^{17}$O, and the number of available neutrons is reduced by low-lying resonances in the $^{16}$O($n$,$γ$)$^{17}$O reaction corresponding to levels in $^{17}$O with excitation energies of $4-5$ MeV. The present work uses the $^{19}$F($d$,$α$)$^{17}$O reaction to determine absolute widths of the relevant levels in $^{17}$O. The results improve the uncertainties of the previously adopted values and resolve a discrepancy between recent studies for the $1/2^+$ level close to the threshold of the $^{13}$C($α$,$n$)$^{16}$O reaction. In addition, improved excitation energies and widths are provided for several states in $^{17}$O up to excitation energies close to 8 MeV.

preprint2015arXiv

High-Rate Capable Floating Strip Micromegas

We report on the optimization of discharge insensitive floating strip Micromegas (MICRO-MEsh GASeous) detectors, fit for use in high-energy muon spectrometers. The suitability of these detectors for particle tracking is shown in high-background environments and at very high particle fluxes up to 60MHz/cm$^2$. Measurement and simulation of the microscopic discharge behavior have demonstrated the excellent discharge tolerance. A floating strip Micromegas with an active area of 48cm$\times$50cm with 1920 copper anode strips exhibits in 120GeV pion beams a spatial resolution of 50$μ$m at detection efficiencies above 95%. Pulse height, spatial resolution and detection efficiency are homogeneous over the detector. Reconstruction of particle track inclination in a single detector plane is discussed, optimum angular resolutions below $5^\circ$ are observed. Systematic deviations of this $μ$TPC-method are fully understood. The reconstruction capabilities for minimum ionizing muons are investigated in a 6.4cm$\times$6.4cm floating strip Micromegas under intense background irradiation of the whole active area with 20MeV protons at a rate of 550kHz. The spatial resolution for muons is not distorted by space charge effects. A 6.4cm$\times$6.4cm floating strip Micromegas doublet with low material budget is investigated in highly ionizing proton and carbon ion beams at particle rates between 2MHz and 2GHz. Stable operation up to the highest rates is observed, spatial resolution, detection efficiencies, the multi-hit and high-rate capability are discussed.

preprint2015arXiv

TPC-like readout for thermal neutron detection using a GEM-detector

Spatial resolution of less than 200 um is challenging for thermal neutron detection. A novel readout scheme based on the time-projection-chamber (TPC) concept is used in a gaseous electron multiplier (GEM) detector. Thermal neutrons are captured in a single 2 um thick Boron-10 converter cathode and secondary Helium and Lithium ions are produced with a combined energy of 2.8 MeV. These ions have sufficient energy to form straight tracks of several mm length. With a time resolving 2-dimensional readout of 400 um pitch in both directions, based on APV25 chips, the ions are tracked and their respective origin in the cathode converter foil is reconstructed. Using an Ar-CO2 93:7% gas mixture, a resolution of 100 um (FWHM 235 um) has been observed with a triple GEM-detector setup at the Garching neutron source (FRMII) for neutrons of 4.7 Angstrom.

preprint2012arXiv

Development of High-Resolution Muon Tracking Systems Based on Micropattern Detectors

A muon tracking system consisting of four 9cm x 10cm sized bulk Micromegas detectors with 128um amplification-gap and two 10cm x 10cm triple GEM detectors is foreseen for high-precision tracking of 140GeV muons at the H8 beamline at CERN with a rate of up to 10kHz and an overall resolution below 40um. Larger detectors with an active area of 0.5m^2 and more are under development for detector studies in high neutron or gamma ray background environments at the Gamma Irradiation Facility at CERN and the Munich tandem accelerator. Signal studies of both detector types have been performed by recording cosmic muon and 5.9keV X-ray signals with a single charge-sensitive preamplifier using several gas-mixtures of Ar:CO_2. The signals were digitized using 1GHz VME based flashADCs with 2520 sampling points. The analysis of the complete signal-cycles allows for the determination of rise times, pulse heights, timing fluctuations and discrimination of background, resulting in a FWHM energy resolution of about 20% and detection efficiencies of 99% and more. Models for signal formation in both detector types will be presented. The single detector spatial resolution of 80um was measured using a fast Gassiplex based strip readout with readout strips of 150um width and a pitch of 250um. The Gassiplex readout, formerly used at the HERMES experiment, had to be substantially adapted. No more crosstalk or non-linearities were observed after reconfiguration of the multiplexing amplifier on the frontend boards. The observed spatial resolution is limited by multiple scattering of the cosmic muons used in the laboratory. We also report on the sensitivity to gamma- and neutron background and on the behaviour of spatial resolution as a function of background rates.

preprint2009arXiv

ATLAS monitored drift tube chambers for super-LHC

After the high-luminosity upgrade of the Large Hadron Collider (LHC) at CERN, the ATLAS muon spectrometer is expected to work at 10 times increased background rates of gammas and neutrons. This is challenging as the momentum resolution of the spectrometer is expected to be 10 %. This requires a single tube resolution of the muon drift tubes of 80 mum. At background rates around 1000 Hz/cm2 space charge effects will lead in the slow and non-linear AR:CO2 = 93:7 gas mixture to a degradation of the drift-tube spatial resolution. This was studied before experimentally for gammas and low energetic neutrons. Almost no information exists for fast neutrons. Therefore, we organized our studies under the following aspects: - We investigated the influence of 11 MeV neutrons on the position resolution of ATLAS MDT chambers. At flux densities between 4 and 16 kHz/cm2, almost no influence on the position resolution was found, it degrades by only 10 mum at a detection efficiency of only 4*10-4. - We investigated inert gas mixtures on fastness and linearity of their position-drifttime (r-t) relation. At a reduction of the maximum drift time by a factor of 2, the use of the present hardware and electronics might be possible. For our experimental studies we used our Munich cosmic ray facility. Two gas mixtures show almost identical position resolution as the standard gas. - For spectrometer regions of highest background rates we contributed to the investigation of newly developed 15 mm drift tubes. Position resolutions have been measured as a function of gamma background rates between 0 and 1400 Hz/cm2. - Garfield simulations have been performed to simulate space charge effects due to gamma irradiation. Results will be presented for the standard geometry as well as for the new 15 mm drift tubes.

preprint2008arXiv

Could the GSI Oscillations be Observed in a Standard Electron Capture Decay Experiment?

The electron-capture decay of 180Re has been investigated to search for oscillations in the decay probability as reported from a recent measurement at GSI, Darmstadt. The production period was kept short compared to the reported oscillation period. No such oscillation was observed, indicating that the reported oscillations would not have been observable in a conventional experiment with radioactive atoms in a solid environment but must have to do with the unique conditions in the GSI experiment where hydrogen-like ions are moving independently in a storage ring and decaying directly by a true two-body decay to a long-lived (ground-) state. Our finding could restrict possible theoretical interpretations of the oscillations.