Source author record

R. Tanuma

Explore this author’s publications, collaborators and research topics. This catalog record has not been claimed by its author.

ResearcherUnclaimed source record

Catalog footprint

Research overview

2works
2topics
4close collaborators

Published work

2 publications

preprint2022arXiv

Measurement of structure dependent radiative K+→e+νγK^{+} \rightarrow e^{+} νγ decays using stopped positive kaons

The structure dependent radiative K+→e+νγK^+ \rightarrow e^+ νγ (Ke2γSD+K_{e2γ}^{\rm SD^+}) decay was investigated with stopped positive kaons. The e+e^+ momentum spectra containing 574±\pm30 Ke2γSD+K_{e2γ}^{\rm SD^+} events with a K+→μ+νK^+ \rightarrow μ^+ ν (Kμ2K_{\mu2}) background of 28±\pm19 events were measured with and without a photon in coincidence and analyzed with Monte Carlo simulations for acceptance and detector response to extract the ratio of the branching ratio of the Ke2γSD+K_{e2γ}^{\rm SD^+} decay and the K+→e+νK^+ \rightarrow e^+ ν decay including the internal bremsstrahlung process (Ke2(γ)K_{e2(γ)}). A value of Br(Ke2γSD+)/Br(Ke2(γ))=1.12±0.07stat±0.04systBr(K_{e2γ}^{\rm SD^+}) / Br(K_{e2(γ)}) = 1.12\pm0.07_{\rm stat} \pm 0.04_{\rm syst} was obtained. This indicates a partial branching ratio, Br(Ke2γSD+, pe>200 MeV/c, Eγ>10 MeV)/Br(Kμ2)=(1.85±0.11stat±0.07syst)×10−5Br(K_{e2γ}^{\rm SD^+}, ~{p_e>200~{\rm MeV}/c}, ~{E_γ>10~{\rm MeV}})/Br(K_{\mu2}) =(1.85 \pm 0.11_{\rm{stat}} \pm 0.07_{\rm{syst}}) \times10^{-5}, which is 25%(∼25\%(\sim2.5σ)σ) higher than the previous experimental result.

preprint2014arXiv

Development of a novel scintillation-trigger detector for the MTV experiment using aluminum-metallized film tapes

A new type of a trigger-scintillation counter array designed for the MTV experiment at TRIUMF-ISAC has been developed, which uses aluminum-metallized film tape for wrapping to achieve the required assembling precision of ±\pm0.5 mm. The MTV experiment uses a cylindrical drift chamber (CDC) as the main electron-tracking detector. The barrel-type trigger counter is placed inside the CDC to generate a trigger signal using 1 mm thick, 300 mm long thin plastic scintillation counters. Detection efficiency and light attenuation compared with conventional wrapping materials are studied.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.