Source author record

R. Silvestri

R. Silvestri appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

8works
4topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

8 published item(s)

preprint2014arXiv

Plurality Consensus in the Gossip Model

We study Plurality Consensus in the Gossip Model over a network of $n$ anonymous agents. Each agent supports an initial opinion or color. We assume that at the onset, the number of agents supporting the plurality color exceeds that of the agents supporting any other color by a sufficiently-large bias. The goal is to provide a protocol that, with high probability, brings the system into the configuration in which all agents support the (initial) plurality color. We consider the Undecided-State Dynamics, a well-known protocol which uses just one more state (the undecided one) than those necessary to store colors. We show that the speed of convergence of this protocol depends on the initial color configuration as a whole, not just on the gap between the plurality and the second largest color community. This dependence is best captured by a novel notion we introduce, namely, the monochromatic distance ${md}(\bar{\mathbf{c}})$ which measures the distance of the initial color configuration $\bar{ \mathbf {c}}$ from the closest monochromatic one. In the complete graph, we prove that, for a wide range of the input parameters, this dynamics converges within $O({md}(\bar {\mathbf {c}}) \log {n})$ rounds. We prove that this upper bound is almost tight in the strong sense: Starting from any color configuration $\bar {\mathbf {c}}$, the convergence time is $Ω({md}(\bar {\mathbf {c}}))$. Finally, we adapt the Undecided-State Dynamics to obtain a fast, random walk-based protocol for plurality consensus on regular expanders. This protocol converges in $O({md}(\bar {\mathbf {c}}) \mathrm{polylog}(n))$ rounds using only $\mathrm{polylog}(n)$ local memory. A key-ingredient to achieve the above bounds is a new analysis of the maximum node congestion that results from performing $n$ parallel random walks on regular expanders. All our bounds hold with high probability.

preprint2011arXiv

Planck early results. III. First assessment of the Low Frequency Instrument in-flight performance

The scientific performance of the Planck Low Frequency Instrument (LFI) after one year of in-orbit operation is presented. We describe the main optical parameters and discuss photometric calibration, white noise sensitivity, and noise properties. A preliminary evaluation of the impact of the main systematic effects is presented. For each of the performance parameters, we outline the methods used to obtain them from the flight data and provide a comparison with pre-launch ground assessments, which are essentially confirmed in flight.

preprint2010arXiv

Cryogenic environment and performance for testing the Planck radiometers

This paper is part of the Prelaunch status LFI papers published on JINST: http://www.iop.org/EJ/journal/-page=extra.proc5/jinst The Planck LFI Radiometer Chain Assemblies (RCAs) have been calibrated in two dedicated cryogenic facilities. In this paper the facilities and the related instrumentation are described. The main satellite thermal interfaces for the single chains have to be reproduced and stability requirements have to be satisfied. Setup design, problems occurred and improving solutions implemented are discussed. Performance of the cryogenic setup are reported.

preprint2010arXiv

Planck pre-launch status: calibration of the Low Frequency Instrument flight model radiometers

The Low Frequency Instrument (LFI) on-board the ESA Planck satellite carries eleven radiometer subsystems, called Radiometer Chain Assemblies (RCAs), each composed of a pair of pseudo-correlation receivers. We describe the on-ground calibration campaign performed to qualify the flight model RCAs and to measure their pre-launch performances. Each RCA was calibrated in a dedicated flight-like cryogenic environment with the radiometer front-end cooled to 20K and the back-end at 300K, and with an external input load cooled to 4K. A matched load simulating a blackbody at different temperatures was placed in front of the sky horn to derive basic radiometer properties such as noise temperature, gain, and noise performance, e.g. 1/f noise. The spectral response of each detector was measured as was their susceptibility to thermal variation. All eleven LFI RCAs were calibrated. Instrumental parameters measured in these tests, such as noise temperature, bandwidth, radiometer isolation, and linearity, provide essential inputs to the Planck-LFI data analysis.

preprint2010arXiv

Planck pre-launch status: Design and description of the Low Frequency Instrument

In this paper we present the Low Frequency Instrument (LFI), designed and developed as part of the Planck space mission, the ESA program dedicated to precision imaging of the cosmic microwave background (CMB). Planck-LFI will observe the full sky in intensity and polarisation in three frequency bands centred at 30, 44 and 70 GHz, while higher frequencies (100-850 GHz) will be covered by the HFI instrument. The LFI is an array of microwave radiometers based on state-of-the-art Indium Phosphide cryogenic HEMT amplifiers implemented in a differential system using blackbody loads as reference signals. The front-end is cooled to 20K for optimal sensitivity and the reference loads are cooled to 4K to minimise low frequency noise. We provide an overview of the LFI, discuss the leading scientific requirements and describe the design solutions adopted for the various hardware subsystems. The main drivers of the radiometric, optical and thermal design are discussed, including the stringent requirements on sensitivity, stability, and rejection of systematic effects. Further details on the key instrument units and the results of ground calibration are provided in a set of companion papers.

preprint2010arXiv

Planck pre-launch status: Low Frequency Instrument calibration and expected scientific performance

We give the calibration and scientific performance parameters of the Planck Low Frequency Instrument (LFI) measured during the ground cryogenic test campaign. These parameters characterise the instrument response and constitute our best pre-launch knowledge of the LFI scientific performance. The LFI shows excellent $1/f$ stability and rejection of instrumental systematic effects; measured noise performance shows that LFI is the most sensitive instrument of its kind. The set of measured calibration parameters will be updated during flight operations through the end of the mission.

preprint2010arXiv

The linearity response of the Planck-LFI flight model receivers

In this paper we discuss the linearity response of the Planck-LFI receivers, with particular reference to signal compression measured on the 30 and 44 GHz channels. In the article we discuss the various sources of compression and present a model that accurately describes data measured during tests performed with individual radiomeric chains. After discussing test results we present the best parameter set representing the receiver response and discuss the impact of non linearity on in-flight calibration, which is shown to be negligible.

preprint2009arXiv

Spectroscopy of Neutron-Rich 168,170Dy: Yrast Band Evolution Close to the NpNn Valence Maximum

The yrast sequence of the neutron-rich dysprosium isotope 168Dy has been studied using multi-nucleon transfer reactions following collisions between a 460-MeV 82Se beam and a 170Er target. The reaction products were identified using the PRISMA magnetic spectrometer and the gamma rays detected using the CLARA HPGe-detector array. The 2+ and 4+ members of the previously measured ground state rotational band of 168Dy have been confirmed and the yrast band extended up to 10+. A tentative candidate for the 4+ to 2+ transition in 170Dy was also identified. The data on these nuclei and on the lighter even-even dysprosium isotopes are interpreted in terms of Total Routhian Surface calculations and the evolution of collectivity in the vicinity of the proton-neutron valence product maximum is discussed.