Researcher profile

R. P. Smith

R. P. Smith contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
8works
0followers
6topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

8 published item(s)

preprint2022arXiv

On a Possibility to Measure the Magnetic Field Inside the CMS Yoke Elements

A procedure to measure the magnetic field inside the CMS yoke elements is considered. Fast discharge of the CMS coil can be used to induce voltages in flux loops installed around selected elements of the CMS yoke. By sampling the voltage induced in any one loop, and integrating the voltage waveform over the time of the discharge, the total initial flux in the loop can be measured. The average value of the magnetic field in the yoke element normal to the plane of the flux loop is obtained by dividing the measured value of the flux by the known area enclosed by the loop and the number of turns in the loop.

preprint2011arXiv

Analysis of Eddy Current Distributions in the CMS Magnet Yoke During the Solenoid Discharge

Flux loops have been installed on selected segments of the magnetic flux return yoke of the 4 T superconducting coil of the Compact Muon Solenoid (CMS) detector under construction at CERN. Voltages induced in the loops during discharge of the solenoid will be sampled online during the entire discharge and integrated offline to provide a measurement of the initial magnetic flux density in steel at the maximum field to an accuracy of a few percent. Although the discharge of the solenoid is rather slow (190 s time constant), the influence of eddy currents induced in the yoke elements should be estimated. The calculation of eddy currents is performed with Vector Fields' program ELEKTRA. The results of the calculations are reported.

preprint2011arXiv

Developing the Technique of Measurements of Magnetic Field in the CMS Steel Yoke Elements With Flux-Loops and Hall Probes

Compact muon solenoid (CMS) is a general-purpose detector designed to run at the highest luminosity at the CERN large hadron collider (LHC). Its distinctive features include a 4 T superconducting solenoid with 6 m diameter by 12.5 m long free bore, enclosed inside a 10000-ton return yoke made of construction steel. Accurate characterization of the magnetic field everywhere in theCMSdetector, including the large ferromagnetic parts of the yoke, is required. To measure the field in and around ferromagnetic parts, a set of flux-loops and Hall probe sensors will be installed on several of the steel pieces. Fast discharges of the solenoid during system commissioning tests will be used to induce voltages in the flux-loops that can be integrated to measure the flux in the steel at full excitation of the solenoid. The Hall sensors will give supplementary information on the axial magnetic field and permit estimation of the remanent field in the steel after the fast discharge. An experimental R&D program has been undertaken, using a test flux-loop, two Hall sensors, and sample disks made from the same construction steel used for the CMS magnet yoke. A sample disc, assembled with the test flux-loop and the Hall sensors, was inserted between the pole tips of a dipole electromagnet equipped with a computer-controlled power supply to measure the excitation of the steel from full saturation to zero field. The results of the measurements are presented and discussed.

preprint2011arXiv

Measurement of the CMS Magnetic Field

The measurement of the magnetic field in the tracking volume inside the superconducting coil of the Compact Muon Solenoid (CMS) detector under construction at CERN is done with a fieldmapper designed and produced at Fermilab. The fieldmapper uses 10 3-D B-sensors (Hall probes) developed at NIKHEF and calibrated at CERN to precision 0.05% for a nominal 4 T field. The precise fieldmapper measurements are done in 33840 points inside a cylinder of 1.724 m radius and 7 m long at central fields of 2, 3, 3.5, 3.8, and 4 T. Three components of the magnetic flux density at the CMS coil maximum excitation and the remanent fields on the steel-air interface after discharge of the coil are measured in check-points with 95 3-D B-sensors located near the magnetic flux return yoke elements. Voltages induced in 22 flux-loops made of 405-turn installed on selected segments of the yoke are sampled online during the entire fast discharge (190 s time-constant) of the CMS coil and integrated offline to provide a measurement of the initial magnetic flux density in steel at the maximum field to an accuracy of a few percent. The results of the measurements made at 4 T are reported and compared with a three-dimensional model of the CMS magnet system calculated with TOSCA.

preprint2011arXiv

Transport and Thermodynamic Evidence for a Marginal Fermi Liquid State in ZrZn$_2$

Measurements of low temperature transport and thermodynamic properties have been used to characterize the non-Fermi liquid state of the itinerant ferromagnet ZrZn$_2$. We observe a $T^{5/3}$ temperature dependence of the electrical resistivity at zero field, which becomes $T^2$ like in an applied field of 9 T. In zero field we also measured the thermal conductivity, and we see a novel linear in $T$ dependence of the difference between the thermal and electrical resistivities. Heat capacity measurements, also at zero field, reveal an upturn in the electronic contribution at low temperatures when the phonon term is subtracted. Taken together, we argue that these properties are consistent with a marginal Fermi liquid state which is predicted by a mean-field model of enhanced spin fluctuations on the border of ferromagnetism in three dimensions. We compare our data to quantitative predictions and establish this model as a compelling theoretical framework for understanding ZrZn$_2$.

preprint2009arXiv

Extraction of many-body configurations from nonlinear absorption in semiconductor quantum wells

Detailed electronic many-body configurations are extracted from quantitatively measured timeresolved nonlinear absorption spectra of resonantly excited GaAs quantum wells. The microscopic theory assigns the observed spectral changes to a unique mixture of electron-hole plasma, exciton, and polarization effects. Strong transient gain is observed only under co-circular pump-probe conditions and is attributed to the transfer of pump-induced coherences to the probe.

preprint2009arXiv

Quantum criticality in ferroelectrics

Materials tuned to the neighbourhood of a zero temperature phase transition often show the emergence of novel quantum phenomena. Much of the effort to study these new effects, like the breakdown of the conventional Fermi-liquid theory of metals has been focused in narrow band electronic systems. Ferroelectric crystals provide a very different type of quantum criticality that arises purely from the crystalline lattice. In many cases the ferroelectric phase can be tuned to absolute zero using hydrostatic pressure or chemical or isotopic substitution. Close to such a zero temperature phase transition, the dielectric constant and other quantities change into radically unconventional forms due to the quantum fluctuations of the electrical polarization. The simplest ferroelectrics may form a text-book paradigm of quantum criticality in the solid-state as the difficulties found in metals due to a high density of gapless excitations on the Fermi surface are avoided. We present low temperature high precision data demonstrating these effects in pure single crystals of SrTiO3 and KTaO3. We outline a model for describing the physics of ferroelectrics close to quantum criticality and highlight the expected 1/T2 dependence of the dielectric constant measured over a wide temperature range at low temperatures. In the neighbourhood of the quantum critical point we report the emergence of a small frequency independent peak in the dielectric constant at approximately 2K in SrTiO3 and 3K in KTaO3 believed to arise from coupling to acoustic phonons. Looking ahead, we suggest that in ferroelectric materials supporting mobile charge carriers, quantum paraelectric fluctuations may mediate new effective electron-electron interactions giving rise to a number of possible states such as superconductivity.

preprint2009arXiv

The Layer 0 Inner Silicon Detector of the D0 Experiment

This paper describes the design, fabrication, installation and performance of the new inner layer called Layer 0 (L0) that was inserted in the existing Run IIa Silicon Micro-Strip Tracker (SMT) of the D0 experiment at the Fermilab Tevatron collider. L0 provides tracking information from two layers of sensors, which are mounted with center lines at a radial distance of 16.1 mm and 17.6 mm respectively from the beam axis. The sensors and readout electronics are mounted on a specially designed and fabricated carbon fiber structure that includes cooling for sensor and readout electronics. The structure has a thin polyimide circuit bonded to it so that the circuit couples electrically to the carbon fiber allowing the support structure to be used both for detector grounding and a low impedance connection between the remotely mounted hybrids and the sensors.