Source author record

R. Chechik

R. Chechik appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

11works
5topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

11 published item(s)

preprint2011arXiv

An Optical Readout TPC (O-TPC) for Studies in Nuclear Astrophysics With Gamma-Ray Beams at HIgS

We report on the construction, tests, calibrations and commissioning of an Optical Readout Time Projection Chamber (O-TPC) detector operating with a CO2(80%) + N2(20%) gas mixture at 100 and 150 Torr. It was designed to measure the cross sections of several key nuclear reactions involved in stellar evolution. In particular, a study of the rate of formation of oxygen and carbon during the process of helium burning will be performed by exposing the chamber gas to intense nearly mono-energetic gamma-ray beams at the High Intensity Gamma Source (HIgS) facility. The O-TPC has a sensitive target-drift volume of 30x30x21 cm^3. Ionization electrons drift towards a double parallel grid avalanche multiplier, yielding charge multiplication and light emission. Avalanche induced photons from N2 emission are collected, intensified and recorded with a Charge Coupled Device (CCD) camera, providing two-dimensional track images. The event's time projection (third coordinate) and the deposited energy are recorded by photomultipliers and by the TPC charge-signal, respectively. A dedicated VME-based data acquisition system and associated data analysis tools were developed to record and analyze these data. The O-TPC has been tested and calibrated with 3.183 MeV alpha-particles emitted by a 148Gd source placed within its volume with a measured energy resolution of 3.0%. Tracks of alpha and 12C particles from the dissociation of 16O and of three alpha-particles from the dissociation of 12C have been measured during initial in-beam test experiments performed at the HIgS facility at Duke University. The full detection system and its performance are described and the results of the preliminary in-beam test experiments are reported.

preprint2011arXiv

THGEM-based detectors for sampling elements in DHCAL: laboratory and beam evaluation

We report on the results of an extensive R&D program aimed at the evaluation of Thick-Gas Electron Multipliers (THGEM) as potential active elements for Digital Hadron Calorimetry (DHCAL). Results are presented on efficiency, pad multiplicity and discharge probability of a 10x10 cm2 prototype detector with 1 cm2 readout pads. The detector is comprised of single- or double-THGEM multipliers coupled to the pad electrode either directly or via a resistive anode. Investigations employing standard discrete electronics and the KPiX readout system have been carried out both under laboratory conditions and with muons and pions at the CERN RD51 test beam. For detectors having a charge-induction gap, it has been shown that even a ~6 mm thick single-THGEM detector reached detection efficiencies above 95%, with pad-hit multiplicity of 1.1-1.2 per event; discharge probabilities were of the order of 1e-6 - 1e-5 sparks/trigger, depending on the detector structure and gain. Preliminary beam tests with a WELL hole-structure, closed by a resistive anode, yielded discharge probabilities of <2e-6 for an efficiency of ~95%. Methods are presented to reduce charge-spread and pad multiplicity with resistive anodes. The new method showed good prospects for further evaluation of very thin THGEM-based detectors as potential active elements for DHCAL, with competitive performances, simplicity and robustness. Further developments are in course.

preprint2010arXiv

Further evaluation of a THGEM UV-photon detector for RICH - comparison with MWPC

The operation of single-, double- and triple-THGEM UV-detectors with reflective CsI photocathodes (CsI-THGEM) in Ne/CH4 and Ne/CF4 mixtures was investigated in view of their potential applications in RICH. The studies were carried out with UV, x-rays and β-electrons and focused on the maximum achievable gain, discharge probability, cathode excitation effects and long-term gain stability. Comparative studies under similar conditions were made in CH4, CF4 and Ne/CF4, with a MWPC coupled to a reflective CsI photocathode (CsI-MWPC). It was found that at counting rates <= 10 Hz/mm^2 the maximum achievable gain of CsI-THGEMs is determined by the Raether limit; at counting rates > 10 Hz/mm^2 it dropped with rate. In all cases investigated the attainable CsI-THGEM gain was significantly higher than that of the CsI-MWPC, under similar conditions. Furthermore, the CsI-THGEM UV-detector suffered fewer cathode-excitation induced effects as compared to CsI-MWPC and had better stability at high counting rates.

preprint2010arXiv

The Thick-COBRA: a New Gaseous Electron Multiplier for Radiation Detectors

The operation principle and preliminary results of a novel gas-avalanche patterned hole electron multiplier, the Thick-COBRA (THCOBRA), are presented. This micro-hole structure is derived from the THGEM and MHSP. Sub-millimeter diameter holes are mechanically drilled in a thin G10 plate, Cu-clad on both faces; on one of the faces the Cu is etched to produce additional anode strips winding between circular cathode strips. Primary avalanches occurring within the holes are followed by additional ones at the anode-strips vicinity. Gains in excess of 5*104 were reached with 22.1 x-rays in Ar, Ne and Ar-10%CH4, with 12.2 % FWHM energy resolution in Ar-10%CH4. Higher gains were measured with single photoelectrons. This robust multiplier may have numerous potential applications.

preprint2009arXiv

Towards THGEM UV-photon detectors for RICH: on single-photon detection efficiency in Ne/CH4 and Ne/CF4

The article deals with the detection efficiency of UV-photon detectors consisting of Thick Gas Electron Multipliers (THGEM) coated with CsI photocathode, operated in atmospheric Ne/CH4 and Ne/CF4 mixtures. We report on the photoelectron extraction efficiency from the photocathode into these gas mixtures, and on the photoelectron collection efficiency into the THGEM holes. Full collection efficiency was reached in all gases investigated, in some cases at relatively low multiplication. High total detector gains for UV photons, in excess of 10^5, were reached at relatively low operation voltages with a single THGEM element. We discuss the photon detection efficiency in the context of possible application to RICH.

preprint2006arXiv

Operation of MHSP multipliers in high pressure pure noble-gas

We report on the performance of a Micro-Hole & Strip Plate (MHSP) electron multiplier operating in pure Xe, Kr, Ar and Ne at the pressure range of 1 to 6 bar. The maximal gains at 1 bar Xe and Kr are 50000 and 100000, respectively; they drop by about one order of magnitude at 2 bar and by almost another order of magnitude at 5-6 bar; they reach gains of 500 and 4000 at 5 bar in Xe and Kr, respectively. In Ar, the gain varies very little with pressure, being 3000-9000; in Ne the maximum attainable gain, about 100000, is pressure independent above 2 bar. The results are compared with that of single- and triple-GEM multipliers operated in similar conditions. Potential applications are in hard X-ray imaging and in cryogenic radiation detectors.

preprint2005arXiv

Ion-induced effects in GEM & GEM/MHSP gaseous photomultipliers for the UV and the visible spectral range

We report on the progress in the study of cascaded GEM and GEM/MHSP gas avalanche photomultipliers operating at atmospheric pressure, with CsI and bialkali photocathodes. They have single-photon sensitivity, ns time resolution and good localization properties. We summarize operational aspects and results, with the highlight of a high-gain stable gated operation of a visible-light device. Of particular importance are the results of a recent ion-backflow reduction study in different cascaded multipliers, affecting the detector's stability and the photocathode's liftime. We report on the significant progress in ion-blocking and provide first results on bialkali-photocathode aging under gas multiplication.

preprint2005arXiv

Thick GEM-like multipliers - a simple solution for large area UV-RICH detectors

We report on the properties of thick GEM-like (THGEM) electron multipliers made of 0.4 mm thick double-sided Cu-clad G-10 plates, perforated with a dense hexagonal array of 0.3 mm diameter drilled holes. Photon detectors comprising THGEMs coupled to semi-transparent CsI photocathodes or reflective ones deposited on the THGEM surface were studied with Ar/CO2 (70:30), Ar/CH4 (95:5), CH4 and CF4. Gains of ~100000 or exceeding 1000000 were reached with single- or double-THGEM, respectively; the signals have 5-10 ns rise times. The electric field configurations at the THGEM electrodes result in an efficient extraction of photoelectrons and their focusing into the holes; this occurs already at rather low gains, below 100. These detectors, with single-photon sensitivity and with expected sub-millimeter localization, can operate at MHz/mm2 rates. We discuss their prospects for large-area UV-photon imaging for RICH.

preprint2004arXiv

Detectors for Energy-Resolved Fast Neutron Imaging

Two detectors for energy-resolved fast-neutron imaging in pulsed broad-energy neutron beams are presented. The first one is a neutron-counting detector based on a solid neutron converter coupled to a gaseous electron multiplier (GEM). The second is an integrating imaging technique, based on a scintillator for neutron conversion and an optical imaging system with fast framing capability.

preprint2004arXiv

Thick GEM-like hole multipliers: properties and possible applications

The properties of thick GEM-like (TGEM) gaseous electron multipliers, operated at 1-740 Torr are presented. They are made of a G-10 plate, perforated with millimeter-scale diameter holes. In single-multiplier elements, effective gains of about 104, 106, and 105 were reached at respective pressures of 1, 10 Torr isobutane and 740 Torr Ar/5%CH4, with pulse rise-times in the few nanosecond scale. The high effective gain at atmospheric pressure was measured with a TGEM coated with a CsI photocathode. The detector was operated in single and cascaded modes. Potential applications in ion and photon detection are discussed.