Source author record

R. A. Etezov

R. A. Etezov appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

6works
3topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

6 published item(s)

preprint2022arXiv

$^{222}$Rn content variations at ground and underground conditions

The activity of $^{222}$Rn and its daughter isotopes was measured in the air of several underground laboratories of the Baksan Neutrino Observatory at various distances from the entrance. The measurements were carried out with the help of the cylindrical ionionization air chamber. We found that the radon content in the ventilated airflow within the measurement accuracy does not depend on the distance travelled along the adit. In addition, we observed that the radon content increases abruptly in those locations where underground gases and water are released. As a result, we review various mechanisms of air enrichment with radon. We also outline our research methodology and present the results of our measurements of radon release from the rocky walls of the underground laboratory. Finally, we present the results of the measurements of the radon content of various ground and underground water sources.

preprint2022arXiv

Characteristics of a matrix proportional counter with circular anodes

The construction of a butt-end multicell matrix proportional counter (MMPC) is presented in the work. Each cell is a butt-end proportional counter with a 5 mm cathode diameter and 0.8 mm circular anode diameter. In the example of the $3\times3$ matrix, it is shown that the gas multiplication of the central cell depends on the potentials at the anodes of the peripheral cells, the drift electrode, the forming rings, and the surrounding metal parts of the structure. The amplitude characteristics were measured when the MMPC was filled with mixtures of 96.3\% Ar + 3.7\% Xe and 90\% Ar + 10\% CH$_4$ at pressures of 620 Torr and 62 Torr. The calibration was carried out with $α$-particles and $γ$-quanta from a $^{238}$Pu source. For photons with energies of 7.5 keV, a resolution of 26\% was obtained. It is shown that, based on MMPC, it is possible to fabricate recording surfaces of arbitrary configuration.

preprint2015arXiv

Characteristics of a thermal neutrons scintillation detector with the [ZnS(Ag)+$^6$LiF] at different conditions of measurements

A construction of a thermal neutron testing detector with a thin [ZnS(Ag)+$^6$LiF] scintillator is described. Results of an investigation of sources of the detector pulse origin and the pulse features in a ground and underground conditions are presented. Measurements of the scintillator own background, registration efficiency and a neutron flux at different objects of the BNO INR RAS were performed. The results are compared with the ones measured by the $^3$He proportional counter.

preprint2015arXiv

High-resolution ion pulse ionization chamber with air filling for the Rn-222 decays detection

The construction and characteristics of the cylindrical ion pulse ionization chamber (CIPIC) with a working volume of 3.2 L are described. The chamber is intended to register alpha-particles from the $^{222}$Rn and its daughter's decays in the filled air sample. The detector is less sensitive to electromagnetic pick-ups and mechanical noises. The digital pulse processing method is proposed to improve the energy resolution of the ion pulse ionization chamber. An energy resolution of 1.6% has been achieved for the 5.49 MeV alpha-line. The dependence of the energy resolution on high voltage and working media pressure has been investigated and the results are presented.

preprint2015arXiv

Results of measurements of an environment neutron background at BNO INR RAS objects with the helium proportional counter

A method of measurements of the environmental neutron background at the Baksan Neutrino Observatory of the INR RAS are described. Measurements were done by using of a proportional counter filled with mixture of Ar(2 at)+$^3$He(4 at). The results obtained at the surface and the underground laboratory of the BNO INR RAS are presented. It is shown that a neutron background in the underground laboratory at the 4900 m w.e. depth is decreased by $\sim 260$ times without any special shield in a comparison with the Earth surface. A neutron flux density in the 5-1323.5~cm air height region is constant within the determination error and equal to $(7.1\pm0.1_{\rm{stat}}\pm0.3_{\rm{syst}})\times10^{-3}$ s$^{-1}\cdot$cm$^{-2}$.