Researcher profile

Qiuhua Huang

Qiuhua Huang contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
7works
0followers
6topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

7 published item(s)

preprint2022arXiv

Learning and Fast Adaptation for Grid Emergency Control via Deep Meta Reinforcement Learning

As power systems are undergoing a significant transformation with more uncertainties, less inertia and closer to operation limits, there is increasing risk of large outages. Thus, there is an imperative need to enhance grid emergency control to maintain system reliability and security. Towards this end, great progress has been made in developing deep reinforcement learning (DRL) based grid control solutions in recent years. However, existing DRL-based solutions have two main limitations: 1) they cannot handle well with a wide range of grid operation conditions, system parameters, and contingencies; 2) they generally lack the ability to fast adapt to new grid operation conditions, system parameters, and contingencies, limiting their applicability for real-world applications. In this paper, we mitigate these limitations by developing a novel deep meta reinforcement learning (DMRL) algorithm. The DMRL combines the meta strategy optimization together with DRL, and trains policies modulated by a latent space that can quickly adapt to new scenarios. We test the developed DMRL algorithm on the IEEE 300-bus system. We demonstrate fast adaptation of the meta-trained DRL polices with latent variables to new operating conditions and scenarios using the proposed method and achieve superior performance compared to the state-of-the-art DRL and model predictive control (MPC) methods.

preprint2022arXiv

Learning to run a power network with trust

Artificial agents are promising for real-time power network operations, particularly, to compute remedial actions for congestion management. However, due to high reliability requirements, purely autonomous agents will not be deployed any time soon and operators will be in charge of taking action for the foreseeable future. Aiming at designing assistant for operators, we instead consider humans in the loop and propose an original formulation. We first advance an agent with the ability to send to the operator alarms ahead of time when the proposed actions are of low confidence. We further model the operator's available attention as a budget that decreases when alarms are sent. We present the design and results of our competition "Learning to run a power network with trust" in which we evaluate our formulation and benchmark the ability of submitted agents to send relevant alarms while operating the network to their best.

preprint2021arXiv

Component Importance and Interdependence Analysis for Transmission, Distribution and Communication Systems

For critical infrastructure restoration planning, the real-time scheduling and coordination of system restoration efforts, the key in decision-making is to prioritize those critical components that are out of service during the restoration. For this purpose, there is a need for component importance analysis. While it has been investigated extensively for individual systems, component importance considering interdependence among transmission, distribution and communication (T&D&C) systems has not been systematically analyzed and widely adopted. In this study, we propose a component importance assessment method in the context of interdependence between T&D&C networks. Analytic methods for multilayer networks and a set of metrics have been applied for assessing the component importance and interdependence between T&D&C networks based on their physical characteristics. The proposed methodology is further validated with integrated synthetic Illinois regional transmission, distribution, and communication (T&D&C) systems, the results reveal the unique characteristics of component/node importance, which may be strongly affected by the network topology and cross-domain node mapping.

preprint2021arXiv

Scalable Voltage Control using Structure-Driven Hierarchical Deep Reinforcement Learning

This paper presents a novel hierarchical deep reinforcement learning (DRL) based design for the voltage control of power grids. DRL agents are trained for fast, and adaptive selection of control actions such that the voltage recovery criterion can be met following disturbances. Existing voltage control techniques suffer from the issues of speed of operation, optimal coordination between different locations, and scalability. We exploit the area-wise division structure of the power system to propose a hierarchical DRL design that can be scaled to the larger grid models. We employ an enhanced augmented random search algorithm that is tailored for the voltage control problem in a two-level architecture. We train area-wise decentralized RL agents to compute lower-level policies for the individual areas, and concurrently train a higher-level DRL agent that uses the updates of the lower-level policies to efficiently coordinate the control actions taken by the lower-level agents. Numerical experiments on the IEEE benchmark 39-bus model with 3 areas demonstrate the advantages and various intricacies of the proposed hierarchical approach.

preprint2020arXiv

Achieving Disaster-Resilient Distribution Systems via Emergency Response Resources: A Practical Approach

This paper presents a practical approach to utilizing emergency response resources (ERRs) and post-disaster available distributed energy resources (PDA-DERs) to improve the resilience of power distribution systems against natural disasters. The proposed approach consists of two sequential steps: first, the minimum amount of ERRs is determined in a pre-disaster planning model; second, a post-disaster restoration model is proposed to co-optimize the dispatch of pre-planned ERRs and PDA-DERs to minimize the impact of disasters on customers, i.e., unserved energy for the entire restoration window. Compared with existing restoration strategies using ERRs, the proposed approach is more tractable since 1) in the pre-disaster stage, the needed EERs are determined based on the prediction of energy shortage and disaster-induced damages using machine learning-based algorithms (i.e., cost-sensitive-RFQRF for prediction of outage customers, random forest for prediction of outage duration, and CART for prediction of disaster-induced damages); 2) in the post-disaster stage, the super-node approximation (SNA) and the convex hull relaxation (CHR) of distribution networks are introduced to achieve the best trade-off between computational burden and accuracy. Tests of the proposed approach on IEEE test feeders demonstrated that a combination of SNA and CHR remarkably reduces the solution time of the post-disaster restoration model.

preprint2020arXiv

Flexibility Management in Economic Dispatch with Dynamic Automatic Generation Control

As the installation of electronically interconnected renewable energy resources grows rapidly in power systems, system frequency maintenance and control become challenging problems to maintain the system reliability in bulk power systems. As two of the most important frequency control actions in the control centers of independent system operators (ISOs) and utilities, the interaction between Economic Dispatch (ED) and Automatic Generation Control (AGC) attracts more and more attention. In this paper, we propose a robust optimization based framework to measure the system flexibility by considering the interaction between two hierarchical processes (i.e., ED and AGC). We propose a cutting plane algorithm with the reformulation technique to obtain seven different indices of the system. In addition, we study the impacts of several system factors (i.e., the budget of operational cost, ramping capability, and transmission line capacity) and show numerically how these factors can influence the system flexibility.

preprint2020arXiv

Hybrid EMT-TS Simulation Strategies to Study High Bandwidth MMC-Based HVdc Systems

Modular multilevel converters (MMCs) are widely used in the design of modern high-voltage direct current (HVdc) transmission system. High-fidelity dynamic models of MMCs-based HVdc system require small simulation time step and can be accurately modeled in electro-magnetic transient (EMT) simulation programs. The EMT program exhibits slow simulation speed and limitation on the size of the model and brings certain challenges to test the high-fidelity HVdc model in system-level simulations. This paper presents the design and implementation of a hybrid simulation framework, which enables the co-simulation of the EMT model of Atlanta-Orlando HVdc line and the transient stability (TS) model of the entire Eastern Interconnection system. This paper also introduces the implementation of two high-fidelity HVdc line models simulated at different time steps and discusses a dedicated method for sizing the buffer areas on both sides of the HVdc line. The simulation results of the two HVdc models with different sizes of buffer areas are presented and compared.