Source author record

Ping Cao

Ping Cao appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

11works
5topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

11 published item(s)

preprint2021arXiv

Back-n White Neutron Source at CSNS and its Applications

Back-streaming neutrons from the spallation target of the China Spallation Neutron Source (CSNS) that emit through the incoming proton channel were exploited to build a white neutron beam facility (the so-called Back-n white neutron source), which was completed in March 2018. The Back-n neutron beam is very intense, at approximately 2*10^7 n/cm^2/s at 55 m from the target, and has a nominal proton beam with a power of 100 kW in the CSNS-I phase and a kinetic energy of 1.6 GeV and a thick tungsten target in multiple slices with modest moderation from the cooling water through the slices. In addition, the excellent energy spectrum spanning from 0.5 eV to 200 MeV, and a good time resolution related to the time-of-flight measurements make it a typical white neutron source for nuclear data measurements; its overall performance is among that of the best white neutron sources in the world. Equipped with advanced spectrometers, detectors, and application utilities, the Back-n facility can serve wide applications, with a focus on neutron-induced cross-section measurements. This article presents an overview of the neutron beam characteristics, the experimental setups, and the ongoing applications at Back-n.

preprint2020arXiv

Measurement of the neutron beam profile of the Back-n white neutron facility at CSNS with a Micromegas detector

The Back-n white neutron beam line, which uses back-streaming white neutrons from the spallation target of the China Spallation Neutron Source, is used for nuclear data measurements. A Micromegas-based neutron detector with two variants was specially developed to measure the beam spot distribution for this beam line. In this article, the design, fabrication, and characterization of the detector are described. The results of the detector performance tests are presented, which include the relative electron transparency, the gain and the gain uniformity, and the neutron beam profile reconstruction capability. The result of the first measurement of the Back-n neutron beam spot distribution is also presented.

preprint2019arXiv

Measurements of differential and angle-integrated cross sections for the $^{10}$B($n, α$)$^{7}$Li reaction in the neutron energy range from 1.0 eV to 2.5 MeV

Differential and angle-integrated cross sections for the $^{10}$B($n, α$)$^{7}$Li, $^{10}$B($n, α$$_{0}$)$^{7}$Li and $^{10}$B($n, α$$_{1}$)$^{7}$Li$^{*}$ reactions have been measured at CSNS Back-n white neutron source. Two enriched (90%) $^{10}$B samples 5.0 cm in diameter and ~85.0 $μ$g/cm$^{2}$ in thickness each with an aluminum backing were prepared, and back-to-back mounted at the sample holder. The charged particles were detected using the silicon-detector array of the Light-charged Particle Detector Array (LPDA) system. The neutron energy E$_{n}$ was determined by TOF (time-of-flight) method, and the valid $α$ events were extracted from the E$_{n}$-Amplitude two-dimensional spectrum. With 15 silicon detectors, the differential cross sections of $α$-particles were measured from 19.2° to 160.8°. Fitted with the Legendre polynomial series, the ($n, α$) cross sections were obtained through integration. The absolute cross sections were normalized using the standard cross sections of the $^{10}$B($n, α$)$^{7}$Li reaction in the 0.3 - 0.5 MeV neutron energy region. The measurement neutron energy range for the $^{10}$B($n, α$)$^{7}$Li reaction is 1.0 eV $\le$ En < 2.5 MeV (67 energy points), and for the $^{10}$B($n, α$$_{0}$)$^{7}$Li and $^{10}$B($n, α$$_{1}$)$^{7}$Li$^{*}$ reactions is 1.0 eV $\le$ En < 1.0 MeV (59 energy points). The present results have been analyzed by the resonance reaction mechanism and the level structure of the $^{11}$B compound system, and compared with existing measurements and evaluations.

preprint2017arXiv

Optimal Drift Rate Control and Impulse Control for a Stochastic Inventory/Production System

In this paper, we consider joint drift rate control and impulse control for a stochastic inventory system under long-run average cost criterion. Assuming the inventory level must be nonnegative, we prove that a $\{(0,q^{\star},Q^{\star},S^{\star}),\{μ^{\star}(x): x\in[0, S^{\star}]\}\}$ policy is an optimal joint control policy, where the impulse control follows the control band policy $(0,q^{\star},Q^{\star},S^{\star})$, that brings the inventory level up to $q^{\star}$ once it drops to $0$ and brings it down to $Q^{\star}$ once it rises to $S^{\star}$, and the drift rate only depends on the current inventory level and is given by function $μ^{\star}(x)$ for the inventory level $x\in[0,S^{\star}]$. The optimality of the $\{(0,q^{\star},Q^{\star},S^{\star}),\{μ^{\star}(x): x\in[0,S^{\star}]\}\}$ policy is proven by using a lower bound approach, in which a critical step is to prove the existence and uniqueness of optimal policy parameters. To prove the existence and uniqueness, we develop a novel analytical method to solve a free boundary problem consisting of an ordinary differential equation (ODE) and several free boundary conditions. Furthermore, we find that the optimal drift rate $μ^{\star}(x)$ is firstly increasing and then decreasing as $x$ increases from $0$ to $S^{\star}$ with a turnover point between $Q^{\star}$ and $S^{\star}$.

preprint2016arXiv

Clock Distributing for BaF2 Readout Electronics at CSNS-WNS

aF2 (Barium Fluoride) detector array is designed for the measurement of (n,γ) cross section precisely at CSNS-WNS (white neutron source at China Spallation Neutron Source). It is a 4πsolid angle-shaped detector array consisting of 92 BaF2 crystal elements. To discriminate signals from BaF2 detector, pulse shape discrimination methodology is used, which is supported by waveform digitization technique. There are total 92 channels for digitizing. The precision and synchronization of clock distribution restricts the performance of waveform digitizing. In this paper, the clock prototype for BaF2 readout electronics at CSNS-WNS is introduced. It is based on PXIe platform and has a twin-stage tree topology. In the first stage, clock is distributed from the tree root to each PXIe crate synchronously through coaxial cable over long distance, while in the second stage, clock is further distributed to each electronic module through PXIe dedicated differential star bus. With the help of this topology, each tree node can fan out up to 20 clocks with 3U size. Test result shows the clock jitter is less than 20ps, which can meet the requirement of BaF2 readout electronics. Besides, this clock system has advantages of high density, simplicity, scalability and cost saving, which makes it can be used in other applications of clock distributing preciously.

preprint2016arXiv

Fast Control Latency Uncertainty Elimination for the BESIII ETOF Upgrade

A new fanning topology is proposed to precisely fan out fast control signals in the Beijing Spectrometer (BES III) end-cap time-of-flight (ETOF) electronics. However, uncertainty in transfer latency is introduced by the new fanning channel, which will degrade the precision of fast control. In this paper, latency uncertainty elimination for the BESIII ETOF upgrade is introduced. The latency uncertainty is determined by a Time-Digital-Converter (TDC) embedded in a Field-Programmable Gate Array (FPGA) and is eliminated by re-capturing at synchronous and determinate time. Compared with the existing method of Barrel-cap TOF (BTOF), it has advantages of flexible structure, easy calibration and good adaptability. Field tests on the BES III ETOF system show that this method effectively eliminates transfer latency uncertainty.

preprint2016arXiv

Proposal of Readout Electronics for CSNS-WNS BaF2 Detector

BaF2 (Barium fluoride) detector is one of the experiment facilities at the under construction CSNS-WNS (White Neutron Source at China Spallation Neutron Source). It is designed for precisely measuring (n,gamma) cross section with total 92 crystal elements and completely 4 pi steradian coverage. In this proposal for readout electronics, waveform digitizing technique with 1GSps sampling rate and 12-bit resolution is adopted to precisely capture the detector signal. To solve the problem of massive data readout and processing, the readout electronics system is designed into a distributed architecture with 4 PXIe crates. The digitized detector's signal is concentrated to PXIe crate controller through PCIe bus on backplane and transmitted to data acquisition system over Gigabit Ethernet in parallel. Besides, clock and trigger can be fanned out synchronously to each electronic channel over a high-precision distributing network. Test results showed that the prototype of the readout electronics system achieved good performance and cooperated well.

preprint2016arXiv

The cosmic ray test of MRPCs for the BESIII ETOF upgrade

In order to improve the particle identification capability of the Beijing Spectrometer III (BESIII),t is proposed to upgrade the current endcap time-of-flight (ETOF) detector with multi-gap resistive plate chamber (MRPC) technology. Aiming at extending ETOF overall time resolution better than 100ps, the whole system including MRPC detectors, new-designed Front End Electronics (FEE), CLOCK module, fast control boards and time to digital modules (TDIG), was built up and operated online 3 months under the cosmic ray. The main purposes of cosmic ray test are checking the detectors' construction quality, testing the joint operation of all instruments and guaranteeing the performance of the system. The results imply MRPC time resolution better than 100$ps$, efficiency is about 98$\%$ and the noise rate of strip is lower than 1$Hz/$($scm^{2}$) at normal threshold range, the details are discussed and analyzed specifically in this paper. The test indicates that the whole ETOF system would work well and satisfy the requirements of upgrade.

preprint2016arXiv

The upgrade system of BESIII ETOF with MRPC technology

The Beijing Spectrometer III (BESIII) endcap Time-Of-Filght (ETOF) was proposed to upgrade with Multigap Resistive Plate Chamber (MRPC) technology to substitute the current ETOF of scintillator+PMT for extending time resolutin better than 80 ps and enhance the particle identification capability to satisfy the higher precision requirement of physics. The ETOF system including MRPC modules, front end electronics (FEE), CLOCK module, fast control boards and time to digital modules (TDIG), has been designed, constructed and done some experimental tests seperately. Aiming at examining the quality of entire ETOF system and training the operation of all participated parts, a cosmic ray test system was built at the laboratory and underwent about three months to guarantee performance. In this paper the results will be presented indicating that the entire ETOF system works well and satisfies the requirements of the upgrade.

preprint2015arXiv

TOT Measurement Implemented in FPGA TDC

Time measurement plays a crucial rule for the purpose of particle identification in high energy physical experiments. With the upgrading of physical goal and the developing of electronics, modern time measurement system meets the requirement of excellent resolution specification as well as high integrity. Due to Field Programmable Gate Array (FPGA), FPGA time-to-digital converter (TDC) becomes one of mature and prominent time measurement methods in recent years. For correcting time-walk effect caused by leading timing, time-over-threshold (TOT) measurement should be added in the FPGA TDC. TOT can be obtained by measuring the interval time of signal leading and trailing edge. Unfortunately, a traditional TDC can recognize only one kind of signal edge, the leading or the trailing. Generally, to measure the interval, two TDC channels can be used at the same time, one for leading, the other for trailing. However, this method will increase the amount of used FPGA resource and reduce the TDC's integrity unavoidably. This paper presents one method of TOT measurement implemented in a Xilinx Virtex-5 FPGA. In this method, TOT measure can be achieved in only one TDC input channel. The consumed resources and time resolution can both be guaranteed. Test shows that this TDC can achieve resolution better than 15 ps for leading edge measurement and 37 ps for TOT measurement. Furthermore, the TDC measuring dead time is about 2 clock cycles, which makes it be good for applications of higher physical event rate