Researcher profile

Peter Fritschel

Peter Fritschel contributes to research discovery and scholarly infrastructure.

ResearcherAffiliation not importedOpen to collaborate

Trust snapshot

Quick read

Trust 21 - EmergingVerification L1Unclaimed author
8works
0followers
7topics
4close collaborators

Actions

Decide how to stay connected

Follow researcher0

Identity and collaboration

How to connect with this researcher

Claiming links this public author record to a researcher profile and unlocks direct collaboration workflows.

Log in to claim

Direct collaboration

Open a focused conversation when the fit is right

Claim this author entity first to unlock direct invitations.

Research graph

See the researcher in context

Open full explorer

Inspect adjacent work, topics, institutions and collaborators without jumping out to a separate graph page.

Building this graph slice

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

8 published item(s)

preprint2022arXiv

Piezo-deformable Mirrors for Active Mode Matching in Advanced LIGO

The detectors of the laser interferometer gravitational-wave observatory (LIGO) are broadly limited by the quantum noise and rely on the injection of squeezed states of light to achieve their full sensitivity. Squeezing improvement is limited by mode mismatch between the elements of the squeezer and the interferometer. In the current LIGO detectors, there is no way to actively mitigate this mode mismatch. This paper presents a new deformable mirror for wavefront control that meets the active mode matching requirements of advanced LIGO. The active element is a piezo-electric transducer, which actuates on the radius of curvature of a 5 mm thick mirror via an axisymmetric flexure. The operating range of the deformable mirror is 120+-8 mD in vacuum, with an additional 200 mD adjustment range accessible out of vacuum. The scattering into higher-order modes is measured to be <0.2% over the nominal beam radius. These piezo-deformable mirrors meet the stringent noise and vacuum requirements of advanced LIGO and will be used for the next observing run (O4) to control the mode-matching between the squeezer and the interferometer.

preprint2022arXiv

Snowmass2021 Cosmic Frontier White Paper: Future Gravitational-Wave Detector Facilities

The next generation of gravitational-wave observatories can explore a wide range of fundamental physics phenomena throughout the history of the universe. These phenomena include access to the universe&#39;s binary black hole population throughout cosmic time, to the universe&#39;s expansion history independent of the cosmic distance ladders, to stochastic gravitational-waves from early-universe phase transitions, to warped space-time in the strong-field and high-velocity limit, to the equation of state of nuclear matter at neutron star and post-merger densities, and to dark matter candidates through their interaction in extreme astrophysical environments or their interaction with the detector itself. We present the gravitational-wave detector concepts than can drive the future of gravitational-wave astrophysics. We summarize the status of the necessary technology, and the research needed to be able to build these observatories in the 2030s.

preprint2015arXiv

In-situ characterization of the thermal state of resonant optical interferometers via tracking of their higher-order mode resonances

Thermal lensing in resonant optical interferometers such as those used for gravitational wave detection is a concern due to the negative impact on control signals and instrument sensitivity. In this paper we describe a method for monitoring the thermal state of such interferometers by probing the higher-order spatial mode resonances of the cavities within them. We demonstrate the use of this technique to measure changes in the Advanced LIGO input mode cleaner cavity geometry as a function of input power, and subsequently infer the optical absorption at the mirror surfaces at the level of 1 ppm per mirror. We also demonstrate the generation of a useful error signal for thermal state of the Advanced LIGO power recycling cavity by continuously tracking the first order spatial mode resonance frequency. Such an error signal could be used as an input to thermal compensation systems to maintain the interferometer cavity geometries in the presence of transients in circulating light power levels, thereby maintaining optimal sensitivity and maximizing the duty-cycle of the detectors.

preprint2014arXiv

Advanced LIGO Two-Stage Twelve-Axis Vibration Isolation and Positioning Platform. Part 1: Design and Production Overview

New generations of gravity wave detectors require unprecedented levels of vibration isolation. This paper presents the final design of the vibration isolation and positioning platform used in Advanced LIGO to support the interferometers core optics. This five-ton two-and-half-meter wide system operates in ultra-high vacuum. It features two stages of isolation mounted in series. The stages are imbricated to reduce the overall height. Each stage provides isolation in all directions of translation and rotation. The system is instrumented with a unique combination of low noise relative and inertial sensors. The active control provides isolation from 0.1 Hz to 30 Hz. It brings the platform motion down to 10^(-11) m/Hz^(0.5) at 1 Hz. Active and passive isolation combine to bring the platform motion below 10^(-12) m/Hz^(0.5) at 10 Hz. The passive isolation lowers the motion below 10^(-13) m/Hz^(0.5) at 100 Hz. The paper describes how the platform has been engineered not only to meet the isolation requirements, but also to permit the construction, testing, and commissioning process of the fifteen units needed for Advanced LIGO observatories.

preprint2014arXiv

Advanced LIGO Two-Stage Twelve-Axis Vibration Isolation and Positioning Platform. Part 2: Experimental Investigation and Tests Results

This paper presents the results of the past seven years of experimental investigation and testing done on the two-stage twelve-axis vibration isolation platform for Advanced LIGO gravity waves observatories. This five-ton two-and-half-meter wide system supports more than a 1000 kg of very sensitive equipment. It provides positioning capability and seismic isolation in all directions of translation and rotation. To meet the very stringent requirements of Advanced LIGO, the system must provide more than three orders of magnitude of isolation over a very large bandwidth. It must bring the motion below 10^(-11) m/(Hz)^0.5 at 1 Hz and 10^(-12) m/(Hz)^0.5 at 10 Hz. A prototype of this system has been built in 2006. It has been extensively tested and analyzed during the following two years. This paper shows how the experimental results obtained with the prototype were used to engineer the final design. It highlights how the engineering solutions implemented not only improved the isolation performance but also greatly simplified the assembly, testing, and commissioning process. During the past two years, five units have been constructed, tested, installed and commissioned at each of the two LIGO observatories. Five other units are being built for an upcoming third observatory. The test results presented show that the system meets the motion requirements, and reach the sensor noise in the control bandwidth.

preprint2013arXiv

Low scatter and ultra-low reflectivity measured in a fused silica window

We investigate the reflectivity and optical scattering characteristics at 1064\,nm of an antireflection coated fused silica window of the type being used in the Advanced LIGO gravitational-wave detectors. Reflectivity is measured in the ultra-low range of 5-10\,ppm (by vendor) and 14-30\,ppm (by us). Using an angle-resolved scatterometer we measure the sample&#39;s Bidirectional Scattering Distribution Function (BSDF) and use this to estimate its transmitted and reflected scatter at roughly 20-40\,ppm and 1\,ppm, respectively, over the range of angles measured. We further inspect the sample&#39;s low backscatter using an imaging scatterometer, measuring an angle resolved BSDF below $10^{-6}$ sr$^{-1}$ for large angles (10$^\circ$--80$^\circ$ from incidence in the plane of the beam). We use the associated images to (partially) isolate scatter from different regions of the sample and find that scattering from the bulk fused silica is on par with backscatter from the antireflection coated optical surfaces. To confirm that the bulk scattering is caused by Rayleigh scattering, we perform a separate experiment, measuring the scattering intensity versus input polarization angle. We estimate that 0.9--1.3\,ppm of the backscatter can be accounted for by Rayleigh scattering of the bulk fused silica. These results indicate that modern antireflection coatings have low enough scatter to not limit the total backscattering of thick fused silica optics.

preprint2012arXiv

DC readout experiment in Enhanced LIGO

The two 4 km long gravitational wave detectors operated by the Laser Interferometer Gravitational-wave Observatory (LIGO) were modified in 2008 to read out the gravitational wave channel using the DC readout form of homodyne detection and to include an optical filter cavity at the output of the detector. As part of the upgrade to Enhanced LIGO, these modifications replaced the radio-frequency (RF) heterodyne system used previously. We describe the motivations for and the implementation of DC readout and the output mode cleaner in Enhanced LIGO. We present characterizations of the system, including measurements and models of the couplings of the noises from the laser source to the gravitational wave readout channel. We show that noise couplings using DC readout are improved over those for RF readout, and we find that the achieved shot-noise-limited sensitivity is consistent with modeled results.

preprint2011arXiv

Arm-length stabilisation for interferometric gravitational-wave detectors using frequency-doubled auxiliary lasers

Residual motion of the arm cavity mirrors is expected to prove one of the principal impediments to systematic lock acquisition in advanced gravitational-wave interferometers. We present a technique which overcomes this problem by employing auxiliary lasers at twice the fundamental measurement frequency to pre-stabilise the arm cavities&#39; lengths. Applying this approach, we reduce the apparent length noise of a 1.3 m long, independently suspended Fabry-Perot cavity to 30 pm rms and successfully transfer longitudinal control of the system from the auxiliary laser to the measurement laser.