Source author record

Pavlos P. Vlachos

Pavlos P. Vlachos appears in the imported research catalog. Authorship, coauthor and topic links are available while profile ownership is still unclaimed.

ResearcherUnclaimed source record

Catalog footprint

What is connected

8works
9topics
4close collaborators

Actions

Connect this record

Log in to claim

Research graph

See the researcher in context

Open full explorer

Inspect adjacent papers, topics, institutions and collaborators without losing the researcher page.

Building this map preview

BZPEER is loading the nearby papers, people, topics and institutions for this page.

Published work

8 published item(s)

preprint2026arXiv

Effect of Electric Charge on Biotherapeutic Transport, Binding and Absorption: A Computational Study

This study explores the effects of electric charge on the dynamics of drug transport and absorption in subcutaneous injections of monoclonal antibodies (mAbs). We develop a novel mathematical and computational model, based on the Nernst-Planck equations and porous media flow theory, to investigate the complex interactions between mAbs and charged species in subcutaneous tissue. The model enables us to study short-term transport dynamics and long-term binding and absorption for two mAbs with different electric properties. We examine the influence of buffer pH, body mass index, injection depth, and formulation concentration on drug distribution and compare our numerical results with experimental data from the literature.

preprint2019arXiv

Uncertainty amplification due to density/refractive-index gradients in volumetric PTV and BOS experiments

We theoretically analyze the effect of density/refractive-index gradients on the measurement precision of Volumetric Particle Tracking Velocimetry (V-PTV) and Background Oriented Schlieren (BOS) experiments by deriving the Cramer-Rao lower bound (CRLB) for the 2D centroid estimation process. A model is derived for the diffraction limited image of a particle or dot viewed through a medium containing density gradients that includes the effect of various experimental parameters such as the particle depth, viewing direction and f-number. Using the model we show that non-linearities in the density gradient field lead to blurring of the particle/dot image. This blurring amplifies the effect of image noise on the centroid estimation process, leading to an increase in the CRLB and a decrease in the measurement precision. The ratio of position uncertainties of a dot in the reference and gradient images is a function of the ratio of the dot diameters and dot intensities. We term this parameter the Amplification Ratio (AR), and we propose a methodology for estimating the position uncertainties in tracking-based BOS measurements. The theoretical predictions of the particle/dot position estimation variance from the CRLB are compared to ray tracing simulations with good agreement. The uncertainty amplification is also demonstrated on experimental BOS images of flow induced by a spark discharge, where we show that regions of high amplification ratio correspond to regions of density gradients. This analysis elucidates the dependence of the position error on density and refractive-index gradient induced distortion parameters, provides a methodology for accounting its effect on uncertainty quantification and provides a framework for optimizing experiment design.

preprint2019arXiv

Uncertainty Quantification in density estimation from Background Oriented Schlieren (BOS) measurements

We present an uncertainty quantification methodology for density estimation from Background Oriented Schlieren (BOS) measurements, in order to provide local, instantaneous, a-posteriori uncertainty bounds on each density measurement in the field of view. Displacement uncertainty quantification algorithms from cross-correlation based Particle Image Velocimetry (PIV) are used to estimate the uncertainty in the dot pattern displacements obtained from cross-correlation for BOS and assess their feasibility. In order to propagate the displacement uncertainty through the density integration procedure, we also develop a novel methodology via the Poisson solver using sparse linear operators. Testing the method using synthetic images of a Gaussian density field showed agreement between the propagated density uncertainties and the true uncertainty. Subsequently the methodology is experimentally demonstrated for supersonic flow over a wedge, showing that regions with sharp changes in density lead to an increase in density uncertainty throughout the field of view, even in regions without these sharp changes. The uncertainty propagation is influenced by the density integration scheme, and for the Poisson solver the density uncertainty increases monotonically on moving away from the regions where the Dirichlet boundary conditions are specified.

preprint2016arXiv

Hemodynamics of Stent Implantation Procedures in Coronary Bifurcations: an in vitro study

Stent implantation in coronary bifurcations presents unique challenges and currently there is no universally accepted stent deployment approach. Despite clinical and computational studies, to date, the effect of each stent implantation method on the coronary artery hemodynamics is not well understood. In this study the hemodynamics of stented coronary bifurcations under pulsatile flow conditions were investigated experimentally. Three implantation methods, provisional side branch (PSB), culotte (CUL), and crush (CRU), were investigated using time-resolved particle image velocimetry (PIV) to measure the velocity fields. Subsequently, hemodynamic parameters including wall shear stress (WSS), oscillatory shear index (OSI), and relative residence time (RRT) were calculated and the pressure field through the vessel was non-invasively quantified. The effects of each stented case were evaluated and compared against an un-stented case. CRU provided the lowest compliance mismatch, but demonstrated detrimental stent interactions. PSB, the clinically preferred method, and CUL maintained many normal flow conditions. However, PSB provided about a 300% increase in both OSI and RRT. CUL yielded a 10% and 85% increase in OSI and RRT, respectively. The results of this study support the concept that different bifurcation stenting techniques result in hemodynamic environments that deviate from that of un-stented bifurcations, to varying degrees.

preprint2014arXiv

Lift and wakes of flying snakes

Flying snakes use a unique method of aerial locomotion: they jump from tree branches, flatten their bodies and undulate through the air to produce a glide. The shape of their body cross-section during the glide plays an important role in generating lift. This paper presents a computational investigation of the aerodynamics of the cross-sectional shape. Two-dimensional simulations of incompressible flow past the anatomically correct cross-section of the species Chrysopelea paradisi show that a significant enhancement in lift appears at a 35-degrees angle of attack, above Reynolds numbers 2000. Previous experiments on physical models also obtained an increased lift, at the same angle of attack. The flow is inherently three-dimensional in physical experiments, due to fluid instabilities, and it is thus intriguing that the enhanced lift also appears in the two-dimensional simulations. The simulations point to the lift enhancement arising from the early separation of the boundary layer on the dorsal surface of the snake profile, without stall. The separated shear layer rolls up and interacts with secondary vorticity in the near-wake, inducing the primary vortex to remain closer to the body and thus cause enhanced suction, resulting in higher lift.

preprint2014arXiv

Particle image velocimetry correlation signal-to-noise ratio metrics and measurement uncertainty quantification

In particle image velocimetry (PIV) the measurement signal is contained in the recorded intensity of the particle image pattern superimposed on a variety of noise sources. The signal-to-noise-ratio (SNR) strength governs the resulting PIV cross correlation and ultimately the accuracy and uncertainty of the resulting PIV measurement. Hence we posit that correlation SNR metrics calculated from the correlation plane can be used to quantify the quality of the correlation and the resulting uncertainty of an individual measurement. In this paper we present a framework for evaluating the correlation SNR using a set of different metrics, which in turn are used to develop models for uncertainty estimation. The SNR metrics and corresponding models presented herein are expanded to be applicable to both standard and filtered correlations. In addition, the notion of a valid measurement is redefined with respect to the correlation peak width in order to be consistent with uncertainty quantification principles and distinct from an outlier measurement. Finally the type and significance of the error distribution function is investigated. These advancements lead to robust uncertainty estimation models, which are tested against both synthetic benchmark data as well as actual experimental measurements. For all cases considered here, standard uncertainties are estimated at the 68.5% confidence level while expanded uncertainties are estimated at 95% confidence level. For all cases the resulting calculated coverage factors approximate the expected theoretical values thus demonstrating the applicability of these new models for estimation of uncertainty for individual PIV measurements.

preprint2014arXiv

Time-resolved particle image velocimetry measurements with wall shear stress and uncertainty quantification for the FDA benchmark nozzle model

We present validation of benchmark experimental data for computational fluid dynamics (CFD) analyses of medical devices using advanced Particle Image Velocimetry (PIV) processing and post-processing techniques. This work is an extension of a previous FDA-sponsored multi-laboratory study, which used a medical device mimicking geometry referred to as the FDA benchmark nozzle model. Time-resolved PIV analysis was performed in five overlapping regions of the model for Reynolds numbers in the nozzle throat of 500, 2,000, 5,000, and 8,000. Images included a two-fold increase in spatial resolution in comparison to the previous study. Data was processed using ensemble correlation, dynamic range enhancement, and phase correlations to increase signal-to-noise ratios and measurement accuracy, and to resolve flow regions with large velocity ranges and gradients, which is typical of many blood-contacting medical devices. Parameters relevant to device safety, including shear stress at the wall and in bulk flow, were computed using radial basis functions (RBF) to improve accuracy. In-field spatially resolved pressure distributions, Reynolds stresses and energy dissipation rates were computed from PIV measurements. Velocity measurement uncertainty was estimated directly from the PIV correlation plane, and uncertainty analysis for wall shear stress at each measurement location was performed using a Monte Carlo model. (truncated abstract)

preprint2013arXiv

Demonstration of Experimental Three Dimensional Finite Time Lyapunov Exponents with Inertial Particles

This work provides an experimental method for simultaneously measuring finite time Lyapunov exponent fields for multiple particle groups, including non-flow tracers, in three-dimensional multiphase flows. From sequences of particle images, e.g., from experimental fluid imaging techniques, we can directly compute the flow map and coherent structures, with out performing the computationally costly numerical integration. This is particularly useful to find three-dimensional Lagrangian coherent structures for inertial particles, that do not follow the bulk fluid velocity, as we demonstrate for a grid turbulence experiment. The technique described may provide a new means for exploring the physics of experimental multi-phase flows.